Page 51
AIR CONDITIONER SERVICE MANUAL EC130-200M-1 Revision 6 Page 44 INSTALLATION / REPLACEMENT A. Locate the Aft Evaporator Blower Assembly into the aft evaporator. B. Install the AN525-10R8 screws and AN960-10L washers to secure the motor. C. Re-make the electrical connection between the blower and the evaporator. 7. REMOVAL, INSTALLATION OF THE CONDENSER SCOOP ASSEMBLY, EC130-200 KITS...
Page 52
AIR CONDITIONER SERVICE MANUAL EC130-200M-1 Revision 6 Page 45 NOTE Perform a maintenance operational check of the Condenser Scoop Assembly on completion of the installation to insure that there is no rubbing or binding of the Scoop Door. NOTE The Condenser Scoop Door is rigged at the factory with a .20 to .40 + .10 inch gap between the Scoop Door and the Scoop Plate assemblies with the...
Page 53
AIR CONDITIONER SERVICE MANUAL EC130-200M-1 Revision 6 Page 46 CAUTION Always use a back-up wrench when removing or installing refrigerant line fittings. NOTE There should be no air leakage paths other than through the inlet and outlet. Seal all other openings including those around the condenser refrigerant tubes. 9. REMOVAL & REPLACEMENT OF CONDENSER BLOWER FAN ASSEMBLY, EC130- 200...
Page 54
AIR CONDITIONER SERVICE MANUAL EC130-200M-1 Revision 6 Page 47 10. REMOVAL, INSTALLATION OF THE CONDENSER ASSEMBLIY, EC130-202 KITS REMOVAL A. Remove attaching hardware securing forward inner baggage compartment panel to condenser assembly. Remove baggage compartment panel. B. Disconnect refrigerant plumbing from condenser fittings once refrigerant is evacuated. Always use a back-up...
Page 55
AIR CONDITIONER SERVICE MANUAL EC130-200M-1 Revision 6 Page 48 C. assembly, and remove bolts. D. Disconnect the ES73131-1 (or -2) Blower motor & Fan assembly from the electrical connector. E. Cut the safety wire attached to the three (3) motor mounting bolts on the EC130-7536-1 Vane Axial Blower, Remove the motor mounting bolts and spacers holding the ES73131 Motor & fan assembly to the...
Page 56
AIR CONDITIONER SERVICE MANUAL EC130-200M-1 Revision 6 Page 49 12. REMOVAL, INSTALLATION / REPLACEMENT OF RECEIVER DRIER BOTTLE REMOVAL A. Access the refrigerant plumbing to Receiver Drier Bottle. For the EC130-200 kits the bottle is located near the condenser assembly. For the EC130-202 kits the bottle is mounted to the side of the condenser assembly. B. It will be necessary to...
Page 57
AIR CONDITIONER SERVICE MANUAL EC130-200M-1 Revision 6 Page 50 13. REMOVAL, INSTALLATION / REPLACEMENT OF BINARY PRESSURE SWITCH REMOVAL A. Access the Binary Pressure Switch located downstream from the condenser assembly (refer to the plumbing schematics Fig 4-17 thru -19). The switch will be located on a machined Y-fitting mounted to the forward bulkhead of the fuel tank bay. It is...
Page 58
AIR CONDITIONER SERVICE MANUAL EC130-200M-1 Revision 6 Page 51 CAUTION Refrigerant servicing should be performed by qualified personnel only! C. Remove the safety wire and mounting screws that attaches the support bracket to the valve coil assembly. D. Disconnect the electrical connector to the by-pass valve assembly. E. Disconnect the refrigerant lines from both sides of the by-pass...
Page 59
AIR CONDITIONER SERVICE MANUAL EC130-200M-1 Revision 6 Page 52 CHAPTER 8 TROUBLESHOOTING 1. SYSTEM TROUBLESHOOTING Prior to troubleshooting a defective system, it is advisable to conduct a visual inspection for general condition, and obvious signs of damage or failure. The following matrix lists the easiest checks, and the most likely problems. Problem Probable Cause Solution System...
Page 60
AIR CONDITIONER SERVICE MANUAL EC130-200M-1 Revision 6 Page 53 Problem Probable Cause Solution System not cooling (Evaporator blowers not operating) i. Forward or Aft evaporator blower circuit breaker tripped. i. Reset circuit breaker. If breaker will not reset, check for short in circuit. System not cooling (Evaporator blowers not operating) j. Forward and aft evaporator blower...