Part No. 18381 Installation Instructions Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer. Utilice esta unidad solamente de la manera indicada por el fabricante. Si tiene alguna duda, contacte al fabricante. Gable-Mounted Solar Attic Ventilator Ventilador de ático a energía solar, de montaje en el alero Model NPSG8 Modelo NPSG8 Important Safety Information Información importante de seguridad IMPORTANT: Read all warning...
Page 2
Page 2 of 6 Illustration – 1 Framed Opening Ilustración – 1 Abertura enmarcada GABLE-MOUNT SOLAR POWER VENTILATOR INSTALLATION INSTRUCTIONS NOTE: Air intake openings must be installed for proper exhaust operation. Best results will be obtained if these openings are located around the eaves. Rectangular soffit vents or continuous soffit vents are suggested. Sq. Ft. of Air Intake Model Opening Needed NPSG8 2.7 TOOLS NEEDED: • electric drill • phillips screw driver...
Page 3
Page 3 of 6 Illustration – 2 Installed Mounting Board Ilustración – 2 Panel de montaje instalado Illustration – 3 Installed Fan Assembly Ilustración – 3 Conjunto del ventilador instalado Illustration – 4 Solar Panel Mounting Bracket Assembly Ilustración – 4 Conjunto de ménsulas de montaje del panel solar 2A. CUT MOUNTING BOARD Size the fan mounting board using the plywood or OSB to completely cover the framed opening created in Step 1. The board must be adequately sized...
Page 4
Page 4 of 6 Illustration – 5 Installed Solar Panel Ilustración – 5 Panel solar instalado Illustration – 6 Wiring Connections Ilustración – 6 Conexiones de cables • Drill a hole in the roof deck near the top of the solar panel location, preferably under a shingle. • Insert terminated wire ends through the hole into the attic. Leave only enough wire on top of the roof so that the wire is not under tension at the selected panel location. • Caulk around the wire in the...
Page 5
Page 5 of 6 Five-Year Limited Warranty Limited, Non-prorated and Transferable Who and What Is Covered and For How Long Provided that the product covered by this warranty have been installed in strict accordance with the Air Vent written installation instructions and in accordance with all local codes and standards, including those pertaining to fire rated construction, Air Vent warrants to the original purchaser or the subsequent owner of the property that the parts described in the...
Page 6
Page 6 of 6 Limitations Air Vent shall not be liable for, and this warranty does not apply to, any failure, defect or damage resulting from or connected with misuse, abuse, neglect or improper handling or storage, or installation not in strict adherence to Air Vent’s written instructions. Air Vent reserves the right to discontinue or modify any of its products, including color, and shall not be liable as a result of such discontinuance or modification. If Air Vent replaces any part...