    							IS Tower Strobe
    Strobe / Illumination Light Wiring Instructions
    The following instructions are for wiring the beacon/strobe light on top of TW-Series towers, as well 
    as wiring the panel light located above the panel hole. 
    These instructions apply to models: TW-LCB, TW-LCK, TW-LCR, TW-LCW, and TW-LCY.
    Locate the beacon/strobe wires and connect to a 24V DC power supply.
    •  Red to +24V DC
    •  Black to - (Ground)
    •  Connect the white trigger wire to the Normally Open (NO) terminal of relay 2 on the IS emergency 
    sub station.  Connect a wire between the common terminal of relay 2 and the positive of the 24V 
    DC power supply.
    Locate the panel light wires and connect to a 24V DC power supply.
    •  Red to +24V DC
    •  Black to - (Ground)
    OFF ON
    NO
    NOC
    NC
    C
    NC1234
    Relay board on back of sub stations
    +
    -
    24VDC
    Panel Light
    Strobe
    Refer to the sub station installation manual for its 
    complete wiring and dip switch setting options.
    Pg. 1
    Tower Strobe Instr.
    0512PH 
    						
    							Pg. 2
    Tower Strobe Instr.
    0813PH Aiphone Corporation
    1700 130th AVE NE  Bellevue, WA 98005
    Ph: (800) 692-0200  Fax: (425) 455-0071
    [email protected]
    SPECIFICATIONS:
    Beacon / Strobe:
    Voltage:     24V DC
    Current:   300 mA   
          144 mA @ 24VDC in steady state mode
          272 mA @ 24VDC in fl ashing mode
    Light source:   LED
    Luminous output:  247 lm
    Wiring:   Black: Ground
       Red: +24V DC
       White: Trigger (+24V DC)
    Wiring Distance:  18awg, 980’
    Operating temp:  -40°F to 149°F
    Panel light:
    Voltage:   24V DC
    Current:   24 mA
    Light source:   LED
    Luminous output:  100 lm
    Wiring:   Black: Ground  
       Red: +24V DC
    Wiring Distance:  18awg, 980’
    Operating temp:  -40°F to 149°F