Aiphone LEF3510 Instructions User Manual
Have a look at the manual Aiphone LEF3510 Instructions User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 161 Aiphone manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
– 11 – 9 LEF-10S with BG-10C and 1 Door Station 2 LEF-10 with 9 Door Stations and Selective Door Release : PS-1225UL, PS-1225S, PS-1225, PS-1215DINPS12 : PT-1210N in North America or AC trans.PT PTPTPTPTPTPTPTPTPT : PS-1225UL, PS-1225S, PS-1255, PS-1215DINPS12 56789DA11 ERY+– 1 E – P1P2P3 DC IN +– 321 4 56789101 ERY+–LP1P2P3 32C 4 BG-10C LEF-10S #1 1 E – 1 E 1 E 1 E 1 E 1 E 1 E 1 E 1 E 56789102 ERY+–LP1P2P3 3C1 4 LEF-10S#2 56789103 ERY+–LP1P2P3 C21 4 LEF-10S#3 56789104 ERY+–LP1P2P3 321 C LEF-10S#4 C6789105 ERY+–LP1P2P3 321 4 LEF-10S #5 5C789106 ERY+–LP1P2P3 321 4 LEF-10S #6 56C89107 ERY+–LP1P2P3 321 4 LEF-10S #7 567C9108 ERY+–LP1P2P3 321 4 LEF-10S #8 5678C109 ERY+–LP1P2P3 321 4 LEF-10S #9 + – 5678910 ERY+– LK2K3 K10K9K8K7K6K5K4 32 C1 4 LEF-10S 5678910 ERY+– LK2K3 K10K9K8K7K6K5K4 32 1C 4 LEF-10S Yellow (2) Black (2) RY-PA – Yellow (2) Black (2) RY-PA – Yellow (2) Black (2) RY-PA – Yellow (2) Black (2) RY-PA – Yellow (2) Black (2) RY-PA – Yellow (2) Black (2) RY-PA – Yellow (2) Black (2) RY-PA – Yellow (2) Black (2) RY-PA – Yellow (2) To Strike & #10 To Strike & #9 To Strike & #8 To Strike & #7 To Strike & #6 To Strike & #5 To Strike & #4 To Strike & #3 To Strike & #2 Black (2) RY-PA +– PS12 PS12 Note: In this system, masters communicate on channel 1. Door stations are on channels 2 ~ 10. LE-D or LE-DA LE-D or LE-DALE-D or LE-DALE-D or LE-DALE-D or LE-DALE-D or LE-DALE-D or LE-DALE-D or LE-DALE-D or LE-DA LE-D or LE-DA Connect 12V DC power supply only. Do not connect AC. Connect 12V DC power supply only. Do not connect AC. Remove the shorting link between E and - terminals at all the LEF masters and door/sub stations. Remove the shorting link between E and - terminals at all the LEF masters and door/sub stations.
– 12 – 2 LEF-10S, 6 Indoor Subs, 2 Door Stations with BG-10C for Chime & All Call : PS-1225UL, PS-1225S, PS-1225, PS-1215DINPS12 PS12Capacitors shown are 15-33 μfd, 25V Non-Polarized (NP-25V) Connect 12V DC power supply only. Do not connect AC. 5678DBDA11 ERY+– 1 E – P1P2P3 DC IN +– 321 4 56789101 ERY+–LP1P2P3 32C 4 BG-10C LEF-10S #1 1 E – LE-A or LE-AN LE-A or LE-AN LE-A or LE-AN LE-A or LE-AN LE-A or LE-AN 1 E – 56789102 ERY+–LP1P2P3 3 1 4 LEF-10S #2 + – 1 E – LE-A or LE-AN 1 E – 1 E – 1 E – 1 E – C LE-D or LE-DALE-D or LE-DA Remove the shorting link between E and - terminals at all the LEF masters and door/sub stations.
– 13 – 6 6 OPERATIONS on LEF LEF is a single talkpath system. While the Occupied LED is lit, do not attempt to select a station or initiate an All Call. If called by a master and sub at the same time, reply to the master’s call handsfree first. When the Occupied LED goes off, select the sub station that called. Calling a master or sub: 1. Depress a station selector button 1 ~ 10. 2. Push the TALK button to speak, and release to listen to the reply. 3. If you wish to ring a tone as an attention-getter, press the PRIV (priv\ acy) and TALK buttons together. Release the PRIV button and hold the TALK button down to speak to the called station. 4. To conclude, depress OFF button. Receiving a call from a sub station: 1. Sub station calls in with tone and call-in LED, which stays lit for approx. 20 seconds. 2. Depress the lit station selector button. 3. Push the TALK button to speak, and release to listen. 4. Depress OFF button when finished. Receiving a call from another master: 1. When a master calls to another master, no station LEDs light up, and the\ responding master answers back handsfree. 2. In-use LED will be on while the initiating master has a station selected. 3. Do not press any buttons on the master when responding to another master’s call. If the pri\ vacy feature is engaged, push TALK button momentarily to release before responding. To set the ma\ ster in privacy mode after communication, press PRIV button again. Door answering (from a master station only): 1. Audio door station calls in with an electronic call tone & LED, which stays lit for approx. 20 se\ conds. NOTE: A 4-stroke chime tone can be heard through the inside stations whe\ n a door station calls in if the BG-10C is included in the system. (Up to 3 door stations can activate chime sound.) 2. Depress the lit selector button, then press TALK to speak, release to listen. Door release with “ ” button: LEF-5, LEF-10, and LEF-10S provide selective door release to multiple doors (one RY-PA for each door). When communication is established to a door station, press the “ ” button to release the corresponding door strike. All Call with “ALL CALL” button: On LEF-10S station only, the all call feature allows an announcement to be made to all the stations in the system. IMPORTANT: The BG-10C is required to make this feature operable. 1. Press ALL CALL button. 2. Press TALK to make an announcement. 3. Press ALL CALL button again to release. Speaker Call-in LED 1~10 Station-selector button 1~10 Voice volume control In-use LED (occupied) All Call transmit button & LED (LEF-10S only)Door release button Privacy button & LED Talk (listen) switch Microphone ON LED OFF switch LEF-5, 10, 10S Speaker Microphone In-use LED (occupied) Privacy button & LED Talk (listen) button Call-in LED 1~3 Station-selector button 1~3 OFF button (w/ON LED) Voice volume control LEF-3 123OFFOCCUPIED PRIV TALK CALL1 234 56 78 910OFF OCUPIED VOICE VOL PRIV ALL CALL TALK CALL – 14 – LEF-10S only Operation Plate for LEF-3 Operation Plate for LEF-5, 10, 10S 7 7 LEF system Troubleshooting Guide Single-master system Mulit-master system Problem Solution BG-10C All Call, Chime, and Music Adaptor: Music is selectively distributed to all LEF station speakers, controlled by switch settings in BG-10C. When any station initiates a call, the music mutes automatically. When door station calls in, chime tone is transmitted to selected inside stations, controlled by switch settings. Privacy (PRIV) feature: When PRIV button is depressed, the calling master can call into a station in “privacy” mode, but the “listen” mode is c\ ut off. To release from PRIV, press TALK momentarily. LE sub stations: To call a master station: 1. Simply press the CALL button, which rings an electronic tone (for as long as button is held)\ . The corresponding LED on the called master station(s) will be lit for approximate\ ly 20 seconds. 2. When master replies, speak handsfree. When called by a sub station while talking to another station: The station’s call-in LED will light for approx. 20 sec., but call tone is muted. (NOTE: If A/B switch is set to B position, the call tone will be heard at a muted level, even if the receiving station has another station selected.) Depress OFF button to disconnect from original call, the depress the selector button with lit call-in LED to answer the next call. 1. No call tone or call-in LED when sub calls master (2-wire connection). 2. Call tone works, but no communication, or communication works, but no call tone. 3. Master stations cannot call each other. 4. Call tone is too loud or too soft. Make sure jumper is installed between E & – at the subs and the master station. Same as above; E & – jumper must be in place. If 3 wires are used, 1 & – are for call-in, and 1 & E are for communication. Check cont\ inuity and connection of wires. The C terminal of the master means “CALL”, and allows master-to-\ master communication. Make sure the C terminal of each master is connected \ to a designated # terminal on all other masters. (example: C at master \ 1 connects to the 1 terminal of all other masters.) Adjust call tone volume with slide switch located under operation plate.\ (Remove plate and use small screwdriver to adjust.) OFF OCCUPIED PRIV. VOICE VOL. TALK CALL AIPHONE LEF-10SALL CALL 10 9 8 7 6 5 4 3 2 1Fill in directory Station- selector (5 or 10) Sub/door call-in ON LED Privacy Door release Voice vol. All call In-use OFF (standby) OFF OCCUPIEDPRIV. VOL. VOICE TALK CALL AIPHONE LEF-3 1 23Fill in directory Station- selector (3) Sub/door call-in ON LED Privacy OFF (standby) Voice vol. In-use
– 13 – 6 6 OPERATIONS on LEF LEF is a single talkpath system. While the Occupied LED is lit, do not attempt to select a station or initiate an All Call. If called by a master and sub at the same time, reply to the master’s call handsfree first. When the Occupied LED goes off, select the sub station that called. Calling a master or sub: 1. Depress a station selector button 1 ~ 10. 2. Push the TALK button to speak, and release to listen to the reply. 3. If you wish to ring a tone as an attention-getter, press the PRIV (priv\ acy) and TALK buttons together. Release the PRIV button and hold the TALK button down to speak to the called station. 4. To conclude, depress OFF button. Receiving a call from a sub station: 1. Sub station calls in with tone and call-in LED, which stays lit for approx. 20 seconds. 2. Depress the lit station selector button. 3. Push the TALK button to speak, and release to listen. 4. Depress OFF button when finished. Receiving a call from another master: 1. When a master calls to another master, no station LEDs light up, and the\ responding master answers back handsfree. 2. In-use LED will be on while the initiating master has a station selected. 3. Do not press any buttons on the master when responding to another master’s call. If the pri\ vacy feature is engaged, push TALK button momentarily to release before responding. To set the ma\ ster in privacy mode after communication, press PRIV button again. Door answering (from a master station only): 1. Audio door station calls in with an electronic call tone & LED, which stays lit for approx. 20 se\ conds. NOTE: A 4-stroke chime tone can be heard through the inside stations whe\ n a door station calls in if the BG-10C is included in the system. (Up to 3 door stations can activate chime sound.) 2. Depress the lit selector button, then press TALK to speak, release to listen. Door release with “ ” button: LEF-5, LEF-10, and LEF-10S provide selective door release to multiple doors (one RY-PA for each door). When communication is established to a door station, press the “ ” button to release the corresponding door strike. All Call with “ALL CALL” button: On LEF-10S station only, the all call feature allows an announcement to be made to all the stations in the system. IMPORTANT: The BG-10C is required to make this feature operable. 1. Press ALL CALL button. 2. Press TALK to make an announcement. 3. Press ALL CALL button again to release. Speaker Call-in LED 1~10 Station-selector button 1~10 Voice volume control In-use LED (occupied) All Call transmit button & LED (LEF-10S only) Door release button Privacy button & LED Talk (listen) switch Microphone ON LED OFF switch LEF-5, 10, 10S Speaker Microphone In-use LED (occupied) Privacy button & LED Talk (listen) button Call-in LED 1~3 Station-selector button 1~3 OFF button (w/ON LED) Voice volume control LEF-3 123OFFOCCUPIED PRIV TALK CALL1 234 56 78 910OFF OCUPIED VOICE VOL PRIV ALL CALL TALK CALL – 14 – LEF-10S only Operation Plate for LEF-3 Operation Plate for LEF-5, 10, 10S 7 7 LEF system Troubleshooting Guide Single-master system Mulit-master system Problem Solution BG-10C All Call, Chime, and Music Adaptor: Music is selectively distributed to all LEF station speakers, controlled by switch settings in BG-10C. When any station initiates a call, the music mutes automatically. When door station calls in, chime tone is transmitted to selected inside stations, controlled by switch settings. Privacy (PRIV) feature: When PRIV button is depressed, the calling master can call into a station in “privacy” mode, but the “listen” mode is c\ ut off. To release from PRIV, press TALK momentarily. LE sub stations: To call a master station: 1. Simply press the CALL button, which rings an electronic tone (for as long as button is held)\ . The corresponding LED on the called master station(s) will be lit for approximate\ ly 20 seconds. 2. When master replies, speak handsfree. When called by a sub station while talking to another station: The station’s call-in LED will light for approx. 20 sec., but call tone is muted. (NOTE: If A/B switch is set to B position, the call tone will be heard at a muted level, even if the receiving station has another station selected.) Depress OFF button to disconnect from original call, the depress the selector button with lit call-in LED to answer the next call. 1. No call tone or call-in LED when sub calls master (2-wire connection). 2. Call tone works, but no communication, or communication works, but no call tone. 3. Master stations cannot call each other. 4. Call tone is too loud or too soft. Make sure jumper is installed between E & – at the subs and the master station. Same as above; E & – jumper must be in place. If 3 wires are used, 1 & – are for call-in, and 1 & E are for communication. Check cont\ inuity and connection of wires. The C terminal of the master means “CALL”, and allows master-to-\ master communication. Make sure the C terminal of each master is connected \ to a designated # terminal on all other masters. (example: C at master \ 1 connects to the 1 terminal of all other masters.) Adjust call tone volume with slide switch located under operation plate.\ (Remove plate and use small screwdriver to adjust.) OFF OCCUPIED PRIV. VOICE VOL. TALK CALLAIPHONE LEF-10SALL CALL 10 9 8 7 6 5 4 3 2 1Fill in directory Station- selector (5 or 10) Sub/door call-in ON LED Privacy Door release Voice vol. All call In-use OFF (standby)OFF OCCUPIEDPRIV. VOL. VOICE TALKCALL AIPHONE LEF-3 1 23Fill in directory Station- selector (3) Sub/door call-in ON LED Privacy OFF (standby) Voice vol.In-use
– 15 – Mulit-master system ProblemSolution Call-in LEDs only light when a sub station calls. A responding master answers handsfree, and therefore does not have to select a station numbe\ r. Make sure all masters are in the OFF (standby) position. The station w\ hose LED above the OFF button is lit is the one that’s on. Check R wire for a short to ground. Take R wire off of terminal. If Occupied light remai\ ns lit, the unit is damaged and needs repair. Check E & – wires from sub for proper connection to master. See #2 solution above. Make sure station number wires are not shorted together. Remove all jumpers between E & – (in multi-master system). Test master station by taking wires off of affected station # ’s, then touch a jumper wire between a station # and – . If multiple call-in LEDs light up, the unit has sustained power surge damage and must be sent in for repair. RY-PA relay is required for each door to be released. Connect black wir\ es to L & – . For selective door release, connect RY-PA between K# (matching station # that door is on) and L , which provides 12V DC when “ ” button is pressed. All Call requires the BG-10C Adaptor with power supply. BG-10C must be installed. Wire from door station must connect to BG-10C\ , 1 of door to DA / DB / DC of BG-10C. – must be connected from LEF master to BG-10C. Door station should be wired directly to BG-10C or first master. Make s\ ure the A/B switch on the back of the LEF master is in the “A” positio\ n. Make sure R line is connected between LEF master and BG-10C. Check connection from P1 , P2 , P3 terminals from LEF-10S to BG-10C.\ P1 should be 10V DC or higher when All Call button is engaged. P2 an\ d P3 carry the voice signal from the initiating master to the BG-10C. B\ e sure to press TALK while making an All Call announcement, and press All Call \ button when finished. Adjust volume levels on front of BG-10C (located behind metal cover pla\ te). Make sure jumpers between E & – are removed. When using the BG-10C for All Call in a system with sub stations, a non-polarized capacitor (\ NP-25V) must be installed in series on each station # line that a sub station is\ on between the BG-10C and LEF-10S. (See diagram on pg. 12) Intercom stations should not be mounted back-to-back on the same wall. \ If they are, they must be installed at least 60cm (2’) apart with insu\ lation isolating them. Adjust voice volume control downward to eliminate feedb\ ack. Adjust “Voice Vol.” upward. Make sure the 1 and – terminals from sub to master are not reversed. System wiring must be run at least 50cm (20”) away from AC wiring, \ fluorescent lights, or dimmer switches. Wires can cross AC at 90 degree\ s. If shielded wire was used, tie all of the shields together and ground one e\ nd to an earth ground. If noise persists, isolate source of the noise and sep\ arate the intercom from the source. 5. Call-in LED lights don’t light up when calling master-to-master. 6. In-use LED is always on. 7. Call tone and call-in LED from subs work fine, but no communication, or vice versa. 8. When sub calls in, multiple call-in LED lights come on. 9. Door release doesn’t work. 10. All Call from LEF-10S doesn’t work. 11. Chime from door station doesn’t work. 12. Chime from door works, but electronic call tone in LEF masters also is heard. 13. All Call doesn’t work, but BG-10C is included in system. 14. All Call pretone and voice volume are too loud or too soft. 15. When an All Call is initiated, all of the LEDs corresponding to sub station channels light up. 16. Feedback is heard between intercom stations in adjacent rooms. 17. Communication to another station is very weak. 18. LEF system has AC hum when listening to another station from a master station. – 16 – 9 9 SPECIFICATIONS (LEF) 8 8 TECHNICAL PRECAUTIONS IMPORTANT: • Aiphone is not responsible for improper installations of its product which result in interference generated by dimmer switches, fluorescent lighting fixtures or other similar electrical devices. Any such installation must be corrected at the source by the installing party. Aiphone also recommends that when installing any of its communication products that the intercom wiring be run at least 50cm (20”) away from any AC wiring. • Cleaning: Clean the units with a soft cloth and gentle cleaner. Do not spray cleaner directly on unit. Do not use an abrasive cleaner or cloth. Power source: 12V DC, 300mA per station. Use one PS-1225UL, PS-1225S, PS-1225, or PS-1215DIN power supply per system. Communication: Push-to-talk, release-to-listen at master station. Master-to-master calling does not turn on station LED at receiving master. Talk channel: 1 channel (talkpath). Occupied LED is lit when the system is in use. Output: 800mW at 20Ω (reception). 500mW at 20Ω (transmission). Wiring: • Single-master system: 2 wires homerun. • Between LEF masters: Min. 4 common (*) + 1 wire per number of stations in the system, looped (See pg. 3) (*)9 common wires are required if All Call and Door Release are included, plus total number of stations in the system (plus add'l wire per door if selective door release is included). • Intermixed system: 3 wires per sub, homerun to the nearest master, or 2 common + 1 individual wire per sub, looped. Door release button contact: 30V DC, 0.1A (resistance load). (" ") Select switch contact: 12V DC, 30mA (for external device control). Wiring distance: 0.65mm 0.8mm 1.0mm 22AWG 20AWG 18AWG 200m 300m 480m 650' 1,000’ 1,600' Dimensions & weight: LEF-3: 180 H x 143 W x 55 D (mm). 7-1/16" H x 5-5/8" W x 2-3/16" D. 420g, 0.93 lbs. approx. LEF-5, 10, 10S: 206 H x 190 W x 55 D (mm). 8-1/8" H x 7-1/2" W x 2-3/16" D. 550g, 1.21 lbs. (LEF-5). 650g, 1.43 lbs. (LEF-10, 10S). http://www.aiphone.net/ WARRANTY Aiphone warrants its products to be free from defects of material and workmanship under normal use and service for a period of one year after delivery to the ultimate user and will repair free of charge or replace at no charge, should it become defective upon which examination shall disclose to be defective and under warranty. Aiphone reserves unto itself the sole right to make the final decision whether there is a defect in materials and/or workmanship; and whether or not the product is within the warranty. This warranty shall not apply to any Aiphone product which has been subject to misuse, neglect, accident, power surge, or to use in violation of instructions furnished, nor extended to units which have been repaired or altered outside of the factory. This warranty does not cover batteries or damage caused by batteries used in connection with the unit. This warranty covers bench repairs only, and any repairs must be made at the shop or place designated in writing by Aiphone. This warranty is limited to the standard specifications listed in the operation manual. This warranty does not cover any supplementary function of a third party product that is added by users or suppliers. Please note that any damage or other issues caused by failure of function or interconnection with Aiphone products is also not covered by this warranty. Aiphone will not be responsible for any costs incurred involving on site service calls. Aiphone will not provide compensation for any loss or damage incurred by the breakdown or malfunction of its products during use, or for any consequent inconvenience or losses that may result. AIPHONE CO., LTD., NAGOYA, JAPAN Issue Date: Nov. 2015 83492 N P1115 AZ 58293 The object area of is the EU.
– 15 – Mulit-master system ProblemSolution Call-in LEDs only light when a sub station calls. A responding master answers handsfree, and therefore does not have to select a station numbe\ r. Make sure all masters are in the OFF (standby) position. The station w\ hose LED above the OFF button is lit is the one that’s on. Check R wire for a short to ground. Take R wire off of terminal. If Occupied light remai\ ns lit, the unit is damaged and needs repair. Check E & – wires from sub for proper connection to master. See #2 solution above. Make sure station number wires are not shorted together. Remove all jumpers between E & – (in multi-master system). Test master station by taking wires off of affected station # ’s, then touch a jumper wire between a station # and – . If multiple call-in LEDs light up, the unit has sustained power surge damage and must be sent in for repair. RY-PA relay is required for each door to be released. Connect black wir\ es to L & – . For selective door release, connect RY-PA between K# (matching station # that door is on) and L , which provides 12V DC when “ ” button is pressed. All Call requires the BG-10C Adaptor with power supply. BG-10C must be installed. Wire from door station must connect to BG-10C\ , 1 of door to DA / DB / DC of BG-10C. – must be connected from LEF master to BG-10C. Door station should be wired directly to BG-10C or first master. Make s\ ure the A/B switch on the back of the LEF master is in the “A” positio\ n. Make sure R line is connected between LEF master and BG-10C. Check connection from P1 , P2 , P3 terminals from LEF-10S to BG-10C.\ P1 should be 10V DC or higher when All Call button is engaged. P2 an\ d P3 carry the voice signal from the initiating master to the BG-10C. B\ e sure to press TALK while making an All Call announcement, and press All Call \ button when finished. Adjust volume levels on front of BG-10C (located behind metal cover pla\ te). Make sure jumpers between E & – are removed. When using the BG-10C for All Call in a system with sub stations, a non-polarized capacitor (\ NP-25V) must be installed in series on each station # line that a sub station is\ on between the BG-10C and LEF-10S. (See diagram on pg. 12) Intercom stations should not be mounted back-to-back on the same wall. \ If they are, they must be installed at least 60cm (2’) apart with insu\ lation isolating them. Adjust voice volume control downward to eliminate feedb\ ack. Adjust “Voice Vol.” upward. Make sure the 1 and – terminals from sub to master are not reversed. System wiring must be run at least 50cm (20”) away from AC wiring, \ fluorescent lights, or dimmer switches. Wires can cross AC at 90 degree\ s. If shielded wire was used, tie all of the shields together and ground one e\ nd to an earth ground. If noise persists, isolate source of the noise and sep\ arate the intercom from the source. 5. Call-in LED lights don’t light up when calling master-to-master. 6. In-use LED is always on. 7. Call tone and call-in LED from subs work fine, but no communication, or vice versa. 8. When sub calls in, multiple call-in LED lights come on. 9. Door release doesn’t work. 10. All Call from LEF-10S doesn’t work. 11. Chime from door station doesn’t work. 12. Chime from door works, but electronic call tone in LEF masters also is heard. 13. All Call doesn’t work, but BG-10C is included in system. 14. All Call pretone and voice volume are too loud or too soft. 15. When an All Call is initiated, all of the LEDs corresponding to sub station channels light up. 16. Feedback is heard between intercom stations in adjacent rooms. 17. Communication to another station is very weak. 18. LEF system has AC hum when listening to another station from a master station. – 16 – 9 9 SPECIFICATIONS (LEF) 8 8 TECHNICAL PRECAUTIONS IMPORTANT: • Aiphone is not responsible for improper installations of its product which result in interference generated by dimmer switches, fluorescent lighting fixtures or other similar electrical devices. Any such installation must be corrected at the source by the installing party. Aiphone also recommends that when installing any of its communication products that the intercom wiring be run at least 50cm (20”) away from any AC wiring. • Cleaning: Clean the units with a soft cloth and gentle cleaner. Do not spray cleaner directly on unit. Do not use an abrasive cleaner or cloth. Power source: 12V DC, 300mA per station. Use one PS-1225UL, PS-1225S, PS-1225, or PS-1215DIN power supply per system. Communication: Push-to-talk, release-to-listen at master station. Master-to-master calling does not turn on station LED at receiving master. Talk channel: 1 channel (talkpath). Occupied LED is lit when the system is in use. Output: 800mW at 20Ω (reception). 500mW at 20Ω (transmission). Wiring: • Single-master system: 2 wires homerun. • Between LEF masters: Min. 4 common (*) + 1 wire per number of stations in the system, looped (See pg. 3) (*)9 common wires are required if All Call and Door Release are included, plus total number of stations in the system (plus add'l wire per door if selective door release is included). • Intermixed system: 3 wires per sub, homerun to the nearest master, or 2 common + 1 individual wire per sub, looped. Door release button contact: 30V DC, 0.1A (resistance load). (" ") Select switch contact: 12V DC, 30mA (for external device control). Wiring distance: 0.65mm 0.8mm 1.0mm 22AWG 20AWG 18AWG 200m 300m 480m 650' 1,000’ 1,600' Dimensions & weight: LEF-3: 180 H x 143 W x 55 D (mm). 7-1/16" H x 5-5/8" W x 2-3/16" D. 420g, 0.93 lbs. approx. LEF-5, 10, 10S: 206 H x 190 W x 55 D (mm). 8-1/8" H x 7-1/2" W x 2-3/16" D. 550g, 1.21 lbs. (LEF-5). 650g, 1.43 lbs. (LEF-10, 10S). http://www.aiphone.net/ WARRANTY Aiphone warrants its products to be free from defects of material and workmanship under normal use and service for a period of one year after delivery to the ultimate user and will repair free of charge or replace at no charge, should it become defective upon which examination shall disclose to be defective and under warranty. Aiphone reserves unto itself the sole right to make the final decision whether there is a defect in materials and/or workmanship; and whether or not the product is within the warranty. This warranty shall not apply to any Aiphone product which has been subject to misuse, neglect, accident, power surge, or to use in violation of instructions furnished, nor extended to units which have been repaired or altered outside of the factory. This warranty does not cover batteries or damage caused by batteries used in connection with the unit. This warranty covers bench repairs only, and any repairs must be made at the shop or place designated in writing by Aiphone. This warranty is limited to the standard specifications listed in the operation manual. This warranty does not cover any supplementary function of a third party product that is added by users or suppliers. Please note that any damage or other issues caused by failure of function or interconnection with Aiphone products is also not covered by this warranty. Aiphone will not be responsible for any costs incurred involving on site service calls. Aiphone will not provide compensation for any loss or damage incurred by the breakdown or malfunction of its products during use, or for any consequent inconvenience or losses that may result. AIPHONE CO., LTD., NAGOYA, JAPAN Issue Date: Nov. 2015 83492 N P1115 AZ 58293 The object area of is the EU.