    							– 1 –
    LEF Series
    OPEN VOICE SELECTIVE CALL INTERCOM
    INSTALLATION & OPERATION MANUAL
    LEF-3 (3-call master)
    LEF-5 (5-call master)
    LEF-10 (10-call master)
    LEF-10S (10-call master w/all call button)
    Models:
    * LEF-5W, LEF-10W & LEF-10SW: 
    w/Terminal Box prewired
    (Not available in North America)
    PRECAUTIONS
    WARNING (Negligence could result in death or serious injury.)
    1.
    2.
    3.
    4.
    5.
    6.
    7.
    8.
    9.
    10. Do not dismantle or alter the unit. Fire or electric shock could result.\
    Keep the unit away from water or any other liquid. Fire or electric shoc\
    k could result.
    For power supply, use Aiphone power supply model specified for use with \
    system. If non-specified product is used, fire or malfunction 
    could result.
    Do not connect any non-specified power source to the +, - terminals. Als\
    o, do not install two power supplies in parallel to a single input. 
    Fire or damage to the unit could result.
    Do not use power supply with a voltage other than specified. Fire or ele\
    ctric shock could result.
    Keep AC cord from being marred or crushed. If the AC cord is damaged, fi\
    re or electric shock could result.
    Do not plug or unplug unit with wet hands. Electric shock could result.
    Insert AC plug completely and securely into AC outlet. Otherwise, fire o\
    r electric shock could result.
    Periodically check for and remove dust on the power plug. If dust is lef\
    t, it could cause the power plug to heat up, resulting in fire.
    Do not put any metal or flammable material into the unit through the ope\
    nings. Fire, electric shock, or unit trouble could result.
    1.
    2.
    3.
    4.
    5.
    6.
    7.
    CAUTION (Negligence could result in injury to people or damage to property.)
    Do not install or make any wire terminations while power supply is plugg\
    ed in. It can cause electrical shock or damage to the unit.
    When mounting the unit on a wall, install the unit in a convenient locat\
    ion, but not where it could be jarred or bumped. Injury could result.
    Before turning on power, make sure wires are not crossed or shorted. If \
    not, fire or electric shock could result.
    Do not place or install the unit in the locations subject to frequent vi\
    bration or impact. If the unit falls, injury to people or damage to the 
    unit could result.
    Do not put anything on the unit or cover the unit with cloth, etc. Fire \
    or unit trouble could result.
    Do not install the unit in any of the following locations. Fire, electri\
    c shock, or unit trouble could result.
    *  Places under direct sunlight (except door station). 
    *  Near heating equipment that varies in temperature.
    *  Places subject to dust, oil, chemicals, hydrogen sulfide (hot spring).\
    *  Places subject to moisture and humidity extremes, such as bathrooms, cel\
    lars, greenhouses, etc.
    *  Places where the temperature is quite low, such as inside a refrigerated\
     area or in front of an air conditioner.
    *  Places subject to steam or smoke (near heating or cooking surfaces).
    *  Where noise generating devices such as dimmer switches or inverter elect\
    rical appliances are closeby.
    *  Locations subject to frequent vibration or impact.
    *  Locations subject to extremely powerful electric fields.
    The unit must be installed and wired by a qualified technician.
    1.
    2.
    3.
    4.
    5.
    6.
    7.
    8.
    9.
    GENERAL PRECAUTIONS
    Keep the unit more than 1m (3.3) away from radio or TV sets.
    Keep the intercom wires more than 30cm (12)  away from AC 100-240V w\
    iring. AC induced noise and/or unit malfunction could result.
    Comply with all third party manufacturing specifications that will be us\
    ed with this system.
    Using a mobile phone or professional-use radio equipment such as walkie-\
    talkie close to the system may cause a malfunction.
    The unit can be damaged if dropped. Handle with care.
    The unit will not work during power failure.
    In areas where broadcasting station antennas are closeby, the intercom s\
    ystem may be affected by radio frequency interference.
    All the units, except for door stations, are designed for indoor use onl\
    y. Do not use at outdoor locations.
    This product, providing door release, should not be used as a crime prev\
    ention device.
             Prohibited                         Do not dismantle unit           \
                   Keep unit away from water                         General precautions  
    						
    							– 1 –
    LEF Series
    OPEN VOICE SELECTIVE CALL INTERCOM
    INSTALLATION & OPERATION MANUAL
    LEF-3 (3-call master)
    LEF-5 (5-call master)
    LEF-10 (10-call master)
    LEF-10S (10-call master w/all call button)
    Models:
    * LEF-5W, LEF-10W & LEF-10SW: 
    w/Terminal Box prewired
    (Not available in North America)
    PRECAUTIONS
    WARNING (Negligence could result in death or serious injury.)
    1.
    2.
    3.
    4.
    5.
    6.
    7.
    8.
    9.
    10. Do not dismantle or alter the unit. Fire or electric shock could result.\
    Keep the unit away from water or any other liquid. Fire or electric shoc\
    k could result.
    For power supply, use Aiphone power supply model specified for use with \
    system. If non-specified product is used, fire or malfunction 
    could result.
    Do not connect any non-specified power source to the +, - terminals. Als\
    o, do not install two power supplies in parallel to a single input. 
    Fire or damage to the unit could result.
    Do not use power supply with a voltage other than specified. Fire or ele\
    ctric shock could result.
    Keep AC cord from being marred or crushed. If the AC cord is damaged, fi\
    re or electric shock could result.
    Do not plug or unplug unit with wet hands. Electric shock could result.
    Insert AC plug completely and securely into AC outlet. Otherwise, fire o\
    r electric shock could result.
    Periodically check for and remove dust on the power plug. If dust is lef\
    t, it could cause the power plug to heat up, resulting in fire.
    Do not put any metal or flammable material into the unit through the ope\
    nings. Fire, electric shock, or unit trouble could result.
    1.
    2.
    3.
    4.
    5.
    6.
    7.
    CAUTION (Negligence could result in injury to people or damage to property.)
    Do not install or make any wire terminations while power supply is plugg\
    ed in. It can cause electrical shock or damage to the unit.
    When mounting the unit on a wall, install the unit in a convenient locat\
    ion, but not where it could be jarred or bumped. Injury could result.
    Before turning on power, make sure wires are not crossed or shorted. If \
    not, fire or electric shock could result.
    Do not place or install the unit in the locations subject to frequent vi\
    bration or impact. If the unit falls, injury to people or damage to the 
    unit could result.
    Do not put anything on the unit or cover the unit with cloth, etc. Fire \
    or unit trouble could result.
    Do not install the unit in any of the following locations. Fire, electri\
    c shock, or unit trouble could result.
    *  Places under direct sunlight (except door station). 
    *  Near heating equipment that varies in temperature.
    *  Places subject to dust, oil, chemicals, hydrogen sulfide (hot spring).\
    *  Places subject to moisture and humidity extremes, such as bathrooms, cel\
    lars, greenhouses, etc.
    *  Places where the temperature is quite low, such as inside a refrigerated\
     area or in front of an air conditioner.
    *  Places subject to steam or smoke (near heating or cooking surfaces).
    *  Where noise generating devices such as dimmer switches or inverter elect\
    rical appliances are closeby.
    *  Locations subject to frequent vibration or impact.
    *  Locations subject to extremely powerful electric fields.
    The unit must be installed and wired by a qualified technician.
    1.
    2.
    3.
    4.
    5.
    6.
    7.
    8.
    9.
    GENERAL PRECAUTIONS
    Keep the unit more than 1m (3.3) away from radio or TV sets.
    Keep the intercom wires more than 30cm (12)  away from AC 100-240V w\
    iring. AC induced noise and/or unit malfunction could result.
    Comply with all third party manufacturing specifications that will be us\
    ed with this system.
    Using a mobile phone or professional-use radio equipment such as walkie-\
    talkie close to the system may cause a malfunction.
    The unit can be damaged if dropped. Handle with care.
    The unit will not work during power failure.
    In areas where broadcasting station antennas are closeby, the intercom s\
    ystem may be affected by radio frequency interference.
    All the units, except for door stations, are designed for indoor use onl\
    y. Do not use at outdoor locations.
    This product, providing door release, should not be used as a crime prev\
    ention device.
             Prohibited                         Do not dismantle unit           \
                   Keep unit away from water                         General precautions 
    – 2 –
    2 NAMES & FEATURES
    LEF-3
    LEF-5, 10, 10S1 Speaker
    2  Call-in LED (3)
    3  Station-Select button (3)
    4  Voice volume control
    5  OFF button (w/ON LED)
    6  Microphone (initiator only)
    7  In-use LED (occupied)
    8  Privacy button & LED indicator
    9  Talk (listen) button
     1  Speaker
      2  Call-in LED (5 or 10)
      3  Station-Select button (5 or 10)
      4  Voice volume control
      5  In-use LED (occupied)
      6  All Call transmit button & LED (LEF-10S only)
      7  Door release button
      8  Microphone (initiator only)
      9  OFF button (w/ON LED)
     10  Privacy button & LED indicator
     11  Talk (listen) button
     
     LEF-5:  5 station buttons and OFF.
      Names & functions
     
    Components available
    •  Intercoms: Masters or subs, intermixable
    Master stations Sub stationsPower supply
    LEF-33-callLEF-55-callLEF-1010-callLEF-10S10-callw/all call button
    LE-DSurface mt.LE-DAFlush mt.LE-A
    LE-AN
    1-call(w/Priv.)
    PS-1225UL 
    PS-1225S
    PS-1225
    12V DC, 2.5A power supplyPS-1215DIN, 12V DC, 1.5A
    •  Additional Sub stations:
    LE-DL:  Surface-mount w/anodized aluminum panel
     AH-108 8Ω horn speaker w/ LT-1 matching 
    transformer & NP-25V (33μfd,bp,25V) • 
    All Call & Background Music (with LEF-10S):
    BG-10C:  All call, chime & music adaptor.
    1 SYSTEM OUTLINE & COMPONENTS
     System outline
    The LEF is a flexible Open Voice Selective Call Intercom system which in\
    tegrates any combination of master and 
    sub stations.  The system features selective calling from any master wit\
    h handsfree reply, call-in and LED from a 
    variety of sub stations, selective door release (except LEF-3), and a \
    variety of other optional features.
    •  LEF intercom (LEF-3, 5,10 or 10S)  •  Packet of screws  • Installation & Operation Manual •  China RoHS paper
      Package contents
    1
    6
    7
    8
    9
    2
    3
    45
    1
    23OFFOCCUPIEDPRIV
    TALKCALL
    1234 56 78 910OFF
    OCUPIED
    VOICE VOL
    PRIV
    ALL CALL TALK
    CALL
    1
    2
    3
    4
    5671011
    8
    9 
    						
    							– 3 –
     Features
    •  Four LEF master stations, intermixable.
    CapacityDoor release
    All Call transmit
    4 stations
    6 stations X
    11 stations X
    Models
    LEF-3
    LEF-5
    LEF-10
    LEF-10S 11 stations XX
    • Optional features:
    *  All Call, chime & Music distribution (w/ BG-10C adaptor, LEF-10S only)
    *  Selective door release (w/ RY-PA relay, 1 per door, excluding LEF-3)
    * 8  Ω horn speaker ( AH-108 w/LT-1 transformer & NP-25V capacitor)
    *  External signaling when door/sub calls (w/ RY-AC/A and external device)
    WIRING:
    •  Loop-wired system with multi-conductor shielded cable.
    All-master system : 4 common wires + 1 wire per number of stations in the system.
    If All Call is included :  Add 4 additional common wires ( P1 ~ P3 , Y ).
    If Door Release is included (LEF-5/10/10S) :  Add 1 common  L  + 1 individual wire 
    for each door to be released (  K#  terminals).
    Single-master system :  2 wires homerun* from each sub to the master.
    Leave jumpers between  E  &   –
      installed.
    *NOTE: It is recommended even in a single master system that 3 wires are used for 
    all sub stations in the system, and that the  E  &   –
      jumpers are removed. This ensures 
    that the wiring is proper in the event of system expansion in the future. 
    Intermixed system  with masters and subs:  3 wires from each sub to the nearest 
    master, or 2 common + 1 individual wire per station on a loop.  Remove jumpers 
    between  E  &   –
      from all stations in a multi-master system.
    Model # # of Conductors Wire # (22AWG)Wire # (18AWG) # of Conductors Wire # (22AWG)
    LEF-1C12
    822212 xx x
    LEF-3C12822212 xx x
    LEF-5C15822215 x20822220
    LEF-10C20 822220 x30822220 + 822210
    LEF-39 822210 xx x
    LEF-512822212 x20822220
    LEF-1020 822220 x30822220 + 822210
    LEF-10S20 822220 x30822220 + 822210
    LE-A3 822203 821803 xx
    LE-B3822203 821803 xx
    LE-D3822203 821803 xx
    LE-DA3822203 821803 xx
    With selective door release and/or camera
    call-up (incl.  K  wires b/n masters, max.)
    Standard Communication (Max. # of stations)
      Wire Reference Chart
    Speaker
    CALL
    LE-D
    LE-DA
    Speaker
    CALLLE-DA
    Speaker
    CALL
    LE-A, 1-call
    LE-AN, w/ PRIVACY
    Speaker
    CALLPRIV. 
    						
    							– 4 –
    To remove the operation
    plate, push either left or
    right side of the plate.
    3 MOUNTING
    •  LEF-3•  LEF-5, 10, 10S•  LE room subs
     Slide LE sub down until it locks onto the prongs. 1, 2 : When running cable on the surface, pass cable through the top or \
    bottom of 
    the chassis and fasten with the wire clamps (attached, one outside and \
    one 
    inside chassis.).
     Wall-mounting
    1.   Remove the operation plate by pressing down on one 
    side and lifting off from the middle. Remove the paper 
    directory card as well, and set aside with operation plate. 
    2.   Loosen the two screws
    ※ in the front case.  (Do not 
    remove screws from front case.)
    3.   Disconnect LEF intercom from the chassis by carefully  unplugging the connectors.
    4.   Mount the back chassis to a single-gang box.
    5.   Terminate wires on screw  terminals inside the chassis.
    6.   Reconnect intercom with connectors and mount to  chassis, tightening the two screws
    ※. Replace the 
    directory card and the operation plate. (Make sure the 
    operation plate is under the small tab at the top when 
    reinstalling.) Peel protective covering off of operation 
    plate.
    ※ LEF-3 is one screw.
     Desk mount with LEW Desktop Terminal Box
    1.   Plug in CN1 & CN2 connectors of LEW-5, LEW-10, or  LEW-10S to multi-pin sockets inside LEF master 
    (Connectors from chassis remain disconnected).  Use 
    clamps on LEF back case to secure the cable.
    2.   Install the terminal box in a convenient place with the  field wiring connected inside.  The cord from the box to 
    the LEF unit is approximately 2.5m (7’7”) long.
    3.  Please note that the  K  terminals are not included in the  LEW Desktop Terminal Box.  The  K  terminals are only 
    located in the back of the LEF master.
    Operation
    Plate Operation
    Plate
    Directory
    Card
     
    Before actually installing the LEF system, the contents on pages 4 ~ 12 \
    must be thoroughly read and understood.
    Operation Plate
    Directory Card
    PUSH
    LEF-3
    intercomSINGLE-GANG 
    BOX
    83.5mm,
    3-5/16
    2 screws
    supplied
    Chassis 
    Loosen
    2
    1SINGLE-GANG 
    BOX 83.5mm,
    3-5/16
    2 screws supplied
    2
    Loosen
    2 screws
    LEF-5/10/10S
    intercom
    Unplug
    while installing
    1
    Chassis
    UP83.5mm,
    3-5/16
    SINGLE-GANG BOX
    Prongs(4)
    2 screws supplied
    LE-A,AN
    Mounting
    bracket
    LEW-5, 10, 10S
    TERMINAL BOX
    WIRE PROTECTOR
    Desk-top use;
    Wall
    WIRE PROTECTOR
    Surface wiring;
    Bottom view
    LEF master
    Clamp
    Back view
    Cut out the cable inlet
    Unplug
    while installing
    Directory
    Card 
    						
    							1 from a sub station can wire to any number 1, 2, or 3 but never C.
    C is only used for internal communication between master stations. See be\
    low.
    Master to Master intercom wiring, internal communication between master \
    stations
    Important: Never wire C to another master station's C terminal.
    Master to sub intercom only, no internal communication between master stations 
    Intercom Operation: · To initiate call at sub station, push the station's Call button.  · To answer sub station call at LEF-3, push the appropriate Station Selecto\
    r button.    · To talk to sub station, press and hold TALK and release to listen.    
     
    PS12  PS-1225UL, PS-1225S, PS-1225, PS-1215DIN Choose either method.
    Operation notes:
    When operating M1, push #2 Station 
    Selector button to listen to "M2", press 
    and hold "TALK" to talk.
    When operating M2, push #1 Station 
    Selector button to listen to "M1", press 
    and hold "TALK" to talk.
    When operating either master station 
    utilizing the "same channel method," 
    push #3 Station Selector button to listen 
    to the other master station, press and 
    hold "TALK" to talk.
    LE-SS/A series stations use colored leads
    1 is red lead
    - is blue lead
    E is black lead
    Notes:
    1 from a sub station can go to
    1, 2 or 3 but never C.
    Only master stations can answer 
    calls and communicate with sub 
    stations.
    *  LE-SS/A is North America only.
    1 
    E
    -
    3  2  1 
    E
    - 
    C 
    R  Y  +
    -+
    LE series sub / door station Single LEF-3
    *Keep  E  /  
    -  jumpers
    only for 2-wire setup
    PS12
    * *
    1 
    E
    -
    3  2  1 
    E
    - 
    C  R  Y  +
    3  2  1 
    E
    - 
    C  R  Y  +
    -+
    LE series sub / 
    door station 
    *Remove  E  /  
    -  jumpers in
    all multimaster systems Multi-master 
    LEF-3 LEF-3
    PS12
    *
    3  2 
    C 
    1 
    E +
    Y 
    - 
    R 
    3 
    C  1 
    2 
    E +
    Y 
    - 
    R 
    +-
    LEF-3“M1” LEF-3“M2” 
    PS12
    -+
    C  2  1 
    3 
    E3  2 
    1 
    C 
    E +
    Y 
    - 
    R 
    +
    Y - 
    R 
    LEF-3
    “Same Channel Method” using channel 3 
    PS12 
    -+3 
    2 
    1 
    E
    - 
    R  Y  +C 
    3 
    2 
    1 
    E
    - 
    R  Y  +C 
    1 
    E
    -
    1 
    E
    -
    Red 
    Black Blue
    LEF-3 LEF-3
    *Remove all  E  /  
    -  jumpers
    LEF-3
     “Parallel Method ”
    LE series sub / door station
    LE-A / LE-DA etc
    LE series sub / door station
    LE-A / LE-DA etc
    LE-SS/ A  series door station*PS12
    Red 
    Black
    Blue
    4 WIRING DIAGRAMS - Important Wiring Rules 
    						
    							RY-PA 
    Black  Yellow to CCTV 
    input 
    LEF-5 channels selective gnd. is
      K  terminal corresponding to the 
    number terminals. Contact will be closed 
    as long as channel # 
    is selected to     +
    to # channels selective gnd.
    PS12
    Door release relay wiring, one relay per door station
    Operation:·  To release the door, push the Station Selector button, then press "" to release.
    ·   When the coil gets 12V DC, the contact changes state, momentarily. Use the relay to trigger a Request-To-Exit   
      input on any standard access control system, or close an open circuit \
    (shown above).
    External Signaling and CCTV relay wiring, one of either relay (or both)\
     per door station
     PS12  PS-1225UL, PS-1225S, PS-1225, PS-1215DIN
    2  1 
    K1 LK2K3K4K5
    LEF-5
      White lead is 12V DC when 
    key button is pressed. 
    Colored lead is ground when 
    channel is selected.
      Brown lead is #1
      Red lead is #2
      Orange lead is #3
    · Relay is activated when  channel is selected and door 
    release button is pressed.
    RY-PA 
    Black 
    Yellow 
    Black wires are a coil. Provide 
    12V DC to trigger contact.  Contact  
    Normally Open (N/O) dry contact 
    1 
    10  V  AC,  1A  , 
    24V DC, 1A  Door strike 
    AC  
    T ransforme  r 
    to  L
    K#
    to 
    channels  
    LEF-5
    1 
    E
    - +
    LK1K2K3K4K5
    - +1 
    E
    - 
    Door Strike AC   T ransforme  r 
    Yellow 
    Black 
    LE-D or LE-DA
    RY-PA 
    LEF-5
    PS12
    Power source 
    for bell strobe,  horn, etc 
    RY-AC/A 
    Contact will close momentarily 
    when sub station that is wired to channel #
    (1, 2, 3, 4, or 5) calls in. White to # 
    Black to LEF 
    -Red to LEF +External device 
    to be triggered  Yellow 
    · 
    ·
    L terminal 12V DC when door 
    release button is pressed.
    K# terminal ground when  
    channel is selected.
    K1  is #1
    K2  is #2
    K3  is #3
    Relay is activated when channel is 
    selected and door release button is 
    pressed. 
    						
    							– 7 –
    5 WIRING
     Terminal definitions
      Call tone adjustment
    3-position volume switch, located under operation plate.
    Adjusts call tone volume to low (far left), medium, high (far right)\
    . LEF-3
    LEW-5LEW-10
    LEF-5, LEF-10, LEF-10S
    (unused terminals have no screws)
     
    Selector switch for Call Tone in Occupied Mode
    * IMPORTANT:  The shorting link between the  E  and   –
      terminals 
    must be removed on all units  when two or more master stations 
    are included in the system.  Leave it attached only in 1-master 
    systems with 2 conductor homerun wiring to each sub station. 
    * LEW-5, LEW-10, and LEW-10S Terminal boxes are not equipped with  K1 
    ~ K5 ,  K1  ~  K10  terminals.
    1 ~ 10:   Station number, establishes communication to other LEF masters (to  C  \
    terminal) or LE subs (to  1  terminal)
    C:   “CALL”, Call receive from another master (and All Call/Chime/Musi\
    c  reception)
    E:  Common communication line
    R:  Activates occupied LED to indicate when any master is ON  (line drops to 0V DC when any master is on.)
    Y:   Occupied mode control during All Call (becomes +9V DC during All Call)\
    L:  Door strike activation (becomes +12V DC when “       ”  button is pressed)
    +, –:   12V DC power supply connection. Use Aiphone PS-1225UL, PS-1225S,  PS-1225, or PS-1215DIN.
    P1:    All Call control (becomes +10V DC when All Call button is pressed and  activates pretone)
    P2, P3:  All Call transmit of audio path from initiating master to BG-10C
       K1  ~  K5  (LEF-5),  K1  ~  K10  (LEF10, 10S): Selective control terminal, used for selective door 
    release (w/RY-PA) from the master to multiple door stations. (  K#  terminal becomes ground (–) 
    when corresponding station number is pressed.)
    LEF surface mount master stations are set in the B position 
    from the factory. This allows a sub call-in tone to be heard at a 
    muted level while the master is in the occupied mode. 
    *If a BG-10C is included in the system, the switch must be set 
    to the A position, which will mute the call tone while the door 
    chime is heard throughout the system.  Otherwise, the chime 
    and call tone will be heard simultaneously.
    “A” position:  Mutes call tone at master while system 
        is in occupied mode.
    “B” position:  Call tone is heard when master is in 
        occupied mode.
    +
    E –
    1
    2
    3
    C
    R
    Y
    1 2 34 5E+ C YP1 P2 67 8910 E– R LP3 K0
    CN2
    CN3
    CN1
    K1
    K2
    K3
    K4
    K5K6
    K7
    K8
    K9
    K10
    CN1
    CN3
    CN2
    to CN1
    socket to CN2
    socket
    to CN3 socket
    Yellow
    Red Shorting link
    Speaker
    LEF-10, 10S 
    Front case 
    back view
    Yellow
    
    1
    2
    3
    4
    5
    E +
    C Y R
    L
    E
    –E
    – E
    –
    1
    2
    3
    4
    5
    E
    +
    C
    Y
    P1
    P2
    P3 6
    7
    8
    9
    10
    RL
    
    LEW-10S
    E– E
    –
    1
    2
    3
    4
    5
    E +
    C Y 6
    7
    8
    9
    10
    R
    L
    
    FRONT CASE
    BACK VIEW
    AB
    (when shipped)
    LEF-3
    A B
    (*mutes call tone
    while Occupied)
    LEF-5
    A
    B
    A
    B (*mutes call tone
    while Occupied)
    (when shipped)
    LEF-10, LEF-10S
    CALL
    LEF-5,10,10S
    3-pos. call tone vol. switch (under operation plate)
    LEF-3 
    						
    							– 8 –
     Wiring Diagrams
    • Three LEF-3 and One Door Station
     LEF All-Master configuration 
    LEF all-master systems are designed to be wired in a looped fashion from\
     the first to last master. 
    • A single-master system can be wired with 2 conductors homerun from each sub. (Wire #822202 or #821802 in North America)
     Cable requirements
    Use multi-conductor cable with an overall shield, non-twisted, 0.65mm to 1.0mm (22AWG to 18AWG), to accommodate the 
    maximum number stations in the system, each of which requires one designated wire, plus up to nine common wires per system, 
    depending on features used. Selective door release adds one additional wire per door being released. Use the gauge specified 
    for the maximum distance between the two farthest stations.
     Power supply
    The entire LEF system can be powered by one power supply (PS-1225UL, PS-1225S, PS-1225, or PS-1215DIN), located near 
    the center of the wire run.
    For a system including the All Call and Chime with the BG-10C, one PS-1225UL, PS-1225S, or PS-1225 will power the BG-10C 
    and the LEF system.
     Surge arrestors
    Severe weather conditions, such as lightning storms, may cause damage to LEF equipment.
    We recommend that power surge protection be installed as follows:  (However, this does not guarantee that no    
    damage will occur).
    • Connect the GROUND terminal of the power supply to an earth ground.  In this case, a separate surge arrester is not  necessary.
    • When using a power supply that has no GROUND terminal, install a surge arrestor near the output as shown.
    • Additional SA-1 surge arrestors can be installed to protect communication lines.  One SA-1 per 2 wires on each master station.
    Connect 12V DC power supply only. 
    Do not connect AC.
    : PS-1225UL
      PS-1225S
      PS-1225
      PS-1215DINPS12
    3
    C
    RY+
    –+–– 2
    ERY+
    –
    LEF-3 #1 LEF-3 #2
    1
    E
    13
    1
    C
    2
    ERY+ –
    LEF-3 #3
    C
    1
    2
    3
    EPS12
    Note: This diagram assigns the master
    stations as station 1, 2, and 3. The door
    station is answered on each station's own
    channel button (1, 2, or 3 respectively).
    LE-D or LE-DA
    PS-1225UL
    PS-1225S
    PS-1225
    PS-1215DIN
        LEF model
    12V DC
    Surge-
    arrestor
    (Aiphone model SA-1)
    Install a surge-arrestor
    (discharging voltage:  100~180V)
    at a location closest to the unit, 
    taken to earth ground.
    Grounded
    Remove the shorting link between E  and  -  terminals at all the LEF 
    masters and door/sub stations. 
    						
    							– 9 –
     Three LEF-5 Masters, Two Door Stations with Door Release
    : PS-1225UL, PS-1225S, PS-1225, 
      PS-1215DINPS12
    : PT-1210N in North America or 
      AC trans.PT
    PT
    •  Two LEF-3 and 2 Door Stations
    Connect 12V DC power supply only. 
    Do not connect AC.
    Connect 12V DC power supply only. 
    Do not connect AC.
    Connect 12V DC power supply only. 
    Do not connect AC.
      Six LEF-5s
    Red
    Yellow (2) To Power
    for Doorbell
    Bell
    White BlackRY-AC/A
    5
    32C
    RE
    Y+–
    L
    +–– 4
    LEF-5
    15
    3C1
    RE
    Y+
    –
    L 4
    LEF-5
    253
    21
    RE
    Y+–
    L
    C
    LEF-5
    4
    E
    1
    Yellow (2)To Strike
    &
    Black (2)RY-PA
    PS12
    Note: This diagram assigns the masters on 
    channels 1 ~ 3, and the door stations on 
    channels 4 and 5. Each stations own 
    channel button is not used in this illustration.
    External doorbell will ring when door #5 
    calls in. 
    LE-D or LE-DA
    –
    E
    1
    LE-D or LE-DA
    E
    : PS-1225UL
      PS-1225S
      PS-1225
      PS-1215DINPS12
    2
    1
    RY+
    –– C
    E
    LEF-3
    3
    E
    1
    RY+
    –
    LEF-3
    2
    C 1
    3
    E
    +––
    1
    PS12
    Note: This diagram assigns both master
    stations to use channel 1 to talk to the 
    other master. The door stations are on
    channels 2 and 3 respectively.
    LE-D or LE-DALE-D or LE-DA
    5
    32C
    RE
    Y+–+–
    4
    LEF-5 #1
    15
    3C1
    RE
    Y+
    – 4
    LEF-5 #2
    25
    C21
    RE
    Y+–
    4
    LEF-5 #3
    35
    321
    RE
    Y+–
    C
    LEF-5 #4
    4C
    321
    RE
    Y+
    –
    4
    LEF-5 #5
    55
    321
    RE
    Y+–
    4
    LEF-5 #6
    C: PS-1225UL
      PS-1225S
      PS-1225
      PS-1215DINPS12
    PS12
    Note: This is an all master system. 
    When one master calls another 
    master, the person at the called
    master responds handsfree. There
    is no station LED indicating which 
    master station has called. Remove the shorting link between
     E  and  -  terminals at all the 
    LEF masters and door/sub stations.
    Remove the shorting link between
     E  and  -  terminals at all the 
    LEF masters and door/sub stations.
    Remove the shorting link between
     E  and  -  terminals at all the
    LEF masters stations. 
    						
    							– 10 –
    Yellow (2)
    +––
    E
    1
    Yellow (2)
    To Strike
    & To Bell & Power
    for station #4
    To Bell & Power
    for station #5
    Black (2)
    RY-PA
    –
    E
    1
    Yellow (2)
    To Strike
    &
    Black (2)
    RY-PA
    +–
    5
    3C1
    RE
    Y+– 4
    LEF-5 #2
    25
    32C
    RE
    Y+–
    4
    LEF-5 #1
    1
    1
    E
    –
    E
    –
    1
    1
    E
    –
    Yellow (2)
    To
    Strike
    &           
    RY-PA
    Yellow (2)
    Maintained Contact* To
    Strike
    &            Maintained
    Contact*        To
    Strike
    &            Maintained
    Contact*   
    RY-PA
    Yellow (2)
    RY-PA
    Yellow (2)
    RY-PA
    Yellow (2)
    RY-PA
    Yellow (2)
    RY-PA
    5
    3
    2
    1
    RE
    Y+–
    LLK4K54
    LEF-5
    5
    3
    2
    1
    RE
    Y+–
    LLK4K54
    LEF-5
    LT-1
    AH-108
    NP-25V
    Blue (2)
    Red (2)
    Red (2)Normally
    open
    button
    Black Red
    White
    Black Red
    White
    LT-1AH-108
    Blue (2)
    SP-20N/A
    NP-25V
    Yellow (2)RY-AC/A
    RY-AC/A
    PS12
    PS12
    NP-25V
    *Maintained contact while station is selected. 
     Connect to video switcher, multiplexer, etc.
    LE-D or LE-DA
    LE-D or LE-DALE-D or LE-DA
    LE-D or 
    LE-DALE-D or LE-DA
    Black (2) Black (2) Black (2) Black (2) Black (2) Black (2)
    LLK3K4K5
    LLK3K4K5
      Two LEF-5, Three LE-D w/Camera Call-up and Door Release
      2 LEF-5, 2 Doors, 3 Speakers with Release and External Signaling
    : PS-1225UL, PS-1225S, PS-1225, 
      PS-1215DINPS12
    : PT-1210N in North America or 
      AC trans.PT
    PTPT PTPTPT
    : PS-1225UL, PS-1225S, PS-1225, PS-1215DINPS12
    : PT-1210N in North America or AC trans.PT
    PTPT
    Capacitors shown are 15-33  μfd, 25V Non-Polarized (NP-25V)Note: 
    This system configuration
    has the master stations assigned
    to channels 1 and 2, and the door
    stations as 3 ~ 5. The relays
    provide a maintained contact for
    camera call-up, and a momentary
    contact for selective door release.
     
    : Diode Value: 
      1N4001~1N4007 Connect 12V DC power 
    supply only. 
    Do not connect AC.
    Connect 12V DC power supply only. 
    Do not connect AC.
    Note:  This system configuration has no 
    master-to master communication. The horns 
    and speaker are shown on channels 1 ~ 3. 
    The door stations are shown on channels 4 and 
    5. When the door station calls, the respective 
    relay will trigger the external bell. Each door 
    station will ring a separate bell in this example.
    Remove the shorting link between E  and  -  terminals at all the 
    LEF masters and door/sub stations.
    (North America only)
    (North America only)
    Remove the shorting link between 
     E  and  -  
    terminals at all the LEF masters and door/sub 
    stations.           
    						