21 GETTING STARTED USING THE SYSTEM APPENDIX SETTING THE SYSTEM Registering areas and remote sites [System setting – Area/Site registration] Required Register areas (for separating stations in your site) and/ or remote sites. The number to which a name is entered is registered as an area or site number. Up to 99 areas and/or sites (up to 31 for sites only) can be registered. Click 1 Area/Site registration in the table of contents. Enter an area name in the cell for the area number 01.2 Be sure to enter an area name. A site cannot be * registered to the number 01. The fi gures under * “Number” in the tables means the area or site numbers. Enter area and/or site names in the cells for other 3 numbers to register more areas and/or sites. Select “Area” or “Site” from the pull-down menu of “Area/• Site”. For a site, enter the IP address (global IP address of the • target site), port number and connection password for the target site. For a site, set “Door release” to enable (ON) or disable • (OFF) the door release action from the target site. Click 4 Temporarily stored to save the current setting results temporarily. If you wish to cancel the setting results you have made, * click a title in the table of contents or “Refresh” in the web browser menu. NOTES: Be sure to register at least one area to the area number 01. (“1” is entered in the cell for the area number 01 as default.) A call number displayed on the master station monitor consists of an area number plus a station number (when called from within your site). Registering zones [System setting – Zone registration] Register zones for paging (transmitting announcements and chime) in your site. The number to which a name is entered is registered as a zone number. Up to 99 zones can be registered. * Zones are groups of stations designated for paging and chime paging. Click 1 Zone registration in the table of contents. Enter a zone name in the cell for the target zone 2 number. The fi gures under Number in the table means the zone * number. Enter zone names in the cells for other numbers to 3 register more zones. Click 4 Temporarily stored to save the current setting results temporarily. If you wish to cancel the setting results you have made, * click a title in the table of contents or “Refresh” in the web browser menu.
22 Registering IP units [System setting – IP unit registration] Register IP units by selecting from the connected ones to the system. To register a PC master station, fi rst install the application * (IS-SOFT) to a PC, then connect the PC to the network and then start IS-SOFT. Click 1 IP unit registration in the table of contents. Click 2 IP unit search. All the IP units connected to the system are displayed in the [Search result] on the lower side of the window. If IP units are not displayed, repeat this step until * displayed. Check the boxes for the IP units you want to register, 3 and then click Add to the imported IP units list. The checked IP units are registered and displayed in [Imported IP units list] on the upper side of the window. Enter data or change settings for the registered IP 4 units as needed. For Port number, the sequential numbers are * automatically assigned as needed. (You can also enter port numbers manually.) Do not use port numbers that overlap those of other * devices connected to the same network. Port number auto-setting • : Click this to assign sequential port numbers automatically. Port forwarding setting • : Click this and you can confi rm the port forwarding settings to be made on the router in another window. If [UPnP] is set to OFF at * [Network setting: Common], make the port forwarding setting on the router with the set contents in this window manually. Click * Reload on this window to update the current port forward setting, and click Close to close this window. Click 5 Temporarily stored to save the current setting results temporarily. If you wish to cancel the setting results you have made, * click a title in the table of contents or “Refresh” in the web browser menu. NOTE: A PC master station must be also registered as an IP unit. First install the application (IS-SOFT) to a PC, then connect the PC to the network and then register it. Registering control units [System setting – Control units composition] Register all the control units (other than IP control units) connected to the system. Click 1 Control units composition in the table of contents. Click to check the radio button under Connected for 2 the unit you will register. Click * Connection check to confi rm the connected units. Connected: yellowish green Not connected: gray Shows a port no. of the central control unit to connect with a room sub control unit or add-on control unit. Shows the ID setting of the room sub control unit or add- on control unit set by the ID setting switches. (Refer to the “INSTALLATION MANUAL” for the local system for details about setting the ID setting switches.) Shows a room sub control unit connected to an IP control unit directly, so the port no. is not displayed. If you use a room sub control unit connected that way, set this to “Connected”. Click 3 Temporarily stored to save the current setting results temporarily. If you wish to cancel the setting results you have made, * click a title in the table of contents or “Refresh” in the web browser menu.
23 GETTING STARTED USING THE SYSTEM APPENDIX SETTING THE SYSTEM Registering stations and PA outputs [System setting – Registering stations] Register all the stations and PA outputs connected in the system, and set the area, station no., station name (or PA output name) and type of station (for sub stations: video door/ audio door/room sub stations other than IP stations) to them. Click 1 Registering stations in the table of contents. Set the area, station no., station name and type of 2 station (for sub stations other than IP stations) to the target stations, and enter names to the target PA outputs. Setting the station no. is required to register the * station to the system. Shows a port no. of the control unit to connect with a * station. It is required to enter a name to the target PA * output when an external unit is connected to the corresponding PA output terminals. For a cell with the * mark, select the target one from the pull-down menu. Do not set stations with the same number in an area. * NOTE: The name of a master station displayed on its monitor in standby mode is up to 16 alphanumeric characters. Other buttons Connection check• Click to confi rm the connected units. Connected: yellowish green Not connected: gray Station type error: pink [Collective setting]: • The following buttons are used to make the settings to all the checked stations at one time. Pressing each button opens another window. * NOTE: Be sure to check all the target stations before using these buttons. Area • Click to set the same area number to all the checked stations.Station number • Click to assign sequential numbers to all the checked stations from top to bottom. The number you enter will be set as the fi rst number and will be assigned to the top station of the ones checked. Other checked stations will be numbered sequentially. Station name • Click to assign the same station (and/or PA output) name and sequential numbers to all the checked stations (and/ or PA outputs) from the top down. Enter a name only. Station type • (sub stations other than IP stations) Click to set the same station type to all the checked sub stations. How to select multiple stations ○ Click to check the stations and PA outputs you will register. ○ By clicking the button for the control unit, all the stations and PA outputs connected to it are checked or canceled. ○ By clicking the button on the top of the list, you can check or cancel all the stations and PA outputs on the list. Click 3 Temporarily stored to save the current setting results temporarily. If you wish to cancel the setting results you have made, * click a title in the table of contents or “Refresh” in the web browser menu.
24 Making detailed settings to stations and control units [System setting – Advanced station settings] Make detailed settings for the registered stations and control units (other than the IP control unit). The settings can be made to a station or control unit individually, or multiple stations of the same type at a time. The setting items differ from the station or control unit type. First select a station (or stations) or control unit, and then open the “Advanced settings” window to make the settings. Basic setting procedure Click Advanced station settings in the table of contents. Click to check the station(s) or control unit where detailed settings are to be made. Multiple stations of the same type can be set together.* (Control units should be set respectively.) All stations of the same type can be selected by clicking the * corresponding button under [Select all by type]. Click Advanced settings. The “Advanced settings” window for the selected station type or control unit opens. Make the settings in the displayed windows. For door and room sub stations The right column of this page For master stations P.25 For control units P.26 When you have fi nished making all the detailed settings: Click Temporarily stored to save the current setting results temporarily. If you wish to cancel the setting results you have made, click * a title in the table of contents or “Refresh” in the web browser menu. Making detailed settings to door stations or room sub stations NOTE: Make the settings to door stations or room sub stations respectively. You cannot select a video door station, audio door station and a room sub station at the same time. The following setting item buttons are displayed in the “Advanced settings” window. Click one of the buttons * A, B and C to open the corresponding setting window, and then make the settings in the displayed window(s). See the detailed instructions for A, B or C below. Click * Close to close the current window and return to the previous window. A Settings on [Called stations] setting window Set the master station(s) in your site and/or a remote site that is (are) to be called from the selected station(s). Up to 20 master stations in your site can be set. Or up to * 19 master stations in your site and a remote site (up to 20 master stations are to be set at the remote site) can be set. Select the “Call priority” from the pull-down menu.1 Click 2 Reference to open another window, then check the target master stations, and then click Close to return to the previous window. The selected master stations are added and displayed in the list. Click * Remote sites to open another window for selecting the remote site as the target to be called from the selected station(s). To delete a station (or stations) and/or remote site from * the list, check the targets in the list and click Delete. Repeat step 3 2 to add more master stations. Click 4 Close to close the current window and return to the previous window. A B C (room sub stations only)
25 GETTING STARTED USING THE SYSTEM APPENDIX SETTING THE SYSTEM B Settings on [Contact input] window (for room sub stations only) Make settings for contact input. [Contact type]: • Select either Normally open (NO) or Normally closed (NC). [Call priority/Answering the page]:• You can select the action of the station when detecting input between ‘calling with appropriate priority’ and ‘answering the page’. Select “Normal”, “Priority”, “Urgent” or “Answering the page”. Close • Click this to close the current window and return to the previous window. C Settings on [Other] window [Transmit volume boost at PTT]:• Select whether to increase the press-to-talk sound volume transmitted to the stations (ON) or not (OFF). [Camera zoom image preset] (video door stations • only): Select the default of camera’s Zoom/Wide function at calling from the 9 zoom positions and 0 (wide) from the pull-down menu. [Call acknowledge tone on/off]: • Select whether to sound the call acknowledge tone of door station or room sub station (ON) or not (OFF). [Backlight adjustment] (video door stations only): • Select the method of adjusting the backlight in the daytime between “Exposure +” and “Exposure –”. [Speaker] (room sub stations only): • Select the speaker to be used between “Built-in speaker” and “External speaker”. When “External speaker” is selected, no sound will be * output from the built-in speaker. Close • Click this to close the current window and return to the previous window. About the priority The order of priority for actions (communication, calling, paging, monitoring, etc.) is as follows depending on the priority setting. Priority Setting Action 1 (high)[Urgent], [Broadcast] Communication, calling, paging, chime paging 2[Priority] 3[Normal] 4 (low)- Monitoring, scan-monitoring Making detailed settings to master stations The following setting item buttons are displayed in the “Advanced settings” window. Click either the button * D or E to open the corresponding setting window, and then make the settings in the displayed window(s). See the detailed instructions for D or E below. Click * Close to close the current window and return to the previous window. D Settings on [Stations to be scan monitored] window Set the scan-monitoring target sub station(s). Up to 20 sub stations in your site can be set. * Click 1 Reference to open another window, then select the target stations, and then click Close to return to the previous window. The selected stations are added and displayed in the list. To delete a station (or stations) from the list, check the * target station(s) in the list and click Delete. Repeat step 2 1 to register more stations. Click 3 Close to close the current window and return to the previous window. E Settings on [Other] window [Master station function: paging, chime, monitor, • door release, and remote site call]: Select whether to enable the following functions of master station (ON) or not (OFF). Starting paging • Starting chime paging• Monitoring/scan-monitoring• Releasing door• Remote site call• Close• Click this to close the current window and return to the previous window. D E
26 Making detailed settings to the central control unit(s), add-on control unit(s) or room sub control unit(s) NOTE: Make the settings to the central control unit(s), add-on control unit(s) or room sub control unit(s) respectively. You cannot select multiple control units at the same time. The following setting item buttons are displayed in the “Advanced settings” window. Click either the button * F or G to open the corresponding setting window, and then make the settings in the displayed window(s). See the detailed instructions for F or G below. Click * Close to close the current window and return to the previous window. F Settings on [Contact input] window (for central control unit(s) only) Set the input method to each of the CONTACT INPUT terminals. Select the input terminal from S1 to S4 from the pull-1 down menu. [Contact type]: 2 Select either Normally open (NO) or Normally closed (NC). [Trigger condition]: 3 Select [None], [Broadcast chime] or [Stop chime] as the trigger condition. When an input is detected, the selected action is triggered. [None]: • None will be triggered if an input is detected. [Broadcast chime]: • Chime paging to the designated zone is triggered if an input is detected. [Stop chime]: • The currently-transmitted chime is stopped if an input is detected. Only when [Broadcast chime] is selected, the following * items are valid. [Sound source]: • Select either [Internal sound source] or [External sound source] as the source of chime. When [Internal sound source] is selected, select a sound fi le or sequence from the registered ones in the list. (You need to register sound fi les (→P. 36) and/or sound sequences in advance.) When [External sound source] is selected, select either “External sound source 1” or “External sound source 2”. [Chime priority]: • Select the priority of chime paging from among “Normal”, “Priority” and “Urgent”. [Zone name]: • Select the target zone of chime paging from the registered ones in the list. Repeat step 4 1 to 3 to make the settings to other terminals. Click 5 Close to close the current window and return to the previous window. G Settings on [Contact output] window Set the trigger condition to each of the CONTACT OUTPUT terminals. Select an output terminal from the pull-down menu.1 Select from L1 to L8 for the central control unit, and * select from L1 to L4 for the add-on control unit and room sub control unit. [Contact type]: 2 Select either Normally open (NO) or Normally closed (NC). [Trigger condition]: 3 Select the action as the trigger condition from among the following. When the selected action is detected, output is triggered. [None]: • No output will be triggered. [Calling notice]: • Set ON or OFF for “Normal”, “Priority” or “Urgent”. [Door release]: • Select one of the registered sub stations in the list to which an electric door strike is connected. (Click Reference , and then select the target station.) [External sound source] (central control unit(s) • only): Select either “External sound source 1” or “External sound source 2” connected to the central control unit. [PA output]: • Select from among “PA output 1” to “PA output 4” connected to the control unit. Repeat step 4 1 to 3 to make the settings to other terminals. Click 5 Close to close the current window and return to the previous window. (central control unit(s) only)F G
27 GETTING STARTED USING THE SYSTEM APPENDIX SETTING THE SYSTEM Registering stations and PA outputs to zones [ System setting – Zone setting] Assign stations and PA outputs to the registered zones. Click 1 Zone setting in the table of contents. Select a zone from the pull-down menu.2 Click 3 Reference to display all the registered stations in your site. Another window opens and the registered stations are displayed in the list. Check to select the target stations.4 Select stations in the following ways. Select stations by checking one by one. • All stations of the same type can be selected by • clicking the corresponding button under [Select all by type]. By clicking the button for the control unit, all the • stations connected to it are checked or canceled. By clicking the button on the top of the list, all the • stations are checked or canceled. Click 5 Close after you have fi nished selecting the stations. In the previous window, the selection results are displayed in the list. When canceling a registered station, check the station in * the list, then click Delete. Register PA outputs in the same way as the stations. * Click 6 Temporarily stored to save the current setting results temporarily. If you wish to cancel the setting results you have made, * click a title in the table of contents or “Refresh” in the web browser menu. Registering sound sequences [Chime setting – Registering sound sequences] Register sound sequences for chime. Up to 20 sequences can be registered. * Click 1 Registering sound sequences in the table of contents. [Sound sequence number]:2 Select the sound sequence number to register a sound sequence from the pull-down menu. [Sound sequence name]:3 Enter the name of sound sequence. Click 4 Add to add sound fi les to the sound sequence. Another window appears. [Step]: 5 Select an unused step number from the pull-down menu. If the selected step number is already used, it can be set * with a new sound source and the old and subsequent ones are renumbered with the following numbers. If an unused number exists before the number you * selected, the unused number is re-selected automatically. Up to 10 steps can be used. * [Sound source]:6 Select a sound fi le from the registered ones and set the repeating time (from 1 to 10) of the sound. When you have fi nished the setting on this window, 7 click Close. In the previous window, the registered sound fi les are displayed in the list. Repeat step 8 2 to 7 to register more sound sequences. Other buttons Edit • If you wish to modify, check the fi le in the list, and then click Edit . Delete • When deleting an added sound fi le, check the fi le in the list, and then click Delete . Click 9 Temporarily stored to save the current setting results temporarily. If you wish to cancel the setting results you have made, * click a title in the table of contents or “Refresh” in the web browser menu. NOTE: It is required to register sound source(s) on the IS-CCU connected to the IS-IPC (as the IP host unit) directly before making this setting. ( →P. 36)
28 Registering daily chime schedule [Chime setting – Registering daily chime schedule] Up to 10 daily schedules can be registered. Click 1 Registering daily chime schedule in the table of contents. [Schedule number]: 2 Select the schedule number to register the daily schedule from the pull-down menu. [Schedule name]: 3 Enter the name of daily schedule. Click 4 Add to add programs. Another window appears. [Chime time]:5 Set the starting time (hour, minute and second). [Sound source]: 6 Check [Sound fi le], [Sound sequence] or [External sound source], and select a fi le, sequence or external sound source from the pull-down menu. [Zone number]: 7 Select the target zone for transmitting chime from the pull-down menu. [Chime priority]: 8 Select the priority of transmitting chime from among “Normal”, “Priority” or “Urgent” from the pull-down menu. When you have fi nished the settings on this screen, 9 click Close. In the previous window, the added program is displayed in the list. 10 Repeat step 4 to 9 to add more programs. Other buttons Edit• If you wish to modify a program, check the program in the list, and then click Edit Delete • When deleting a program, check the program in the list, and then click Delete . 11 Click Temporarily stored to save the current setting results temporarily. If you wish to cancel the setting results you have made, * click a title in the table of contents or “Refresh” in the web browser menu. Setting chime schedule [Chime setting – Chime schedule setting] You can set a weekly chime schedule or individual daily schedule. * The settings can be made to 1 year ahead. Click 1 Chime schedule setting in the table of contents. Make the settings by clicking 2 Weekly schedule, Individual schedule and Schedule download respectively to open the corresponding window. Individual schedule* should be clicked after the target date is clicked on the calendar. Make the settings in the displayed window(s). 3 See the detailed instructions for H, I or J on the next page. After the setting is fi nished on the corresponding 4 window, click Close to close the window. Calendar and setting status can be checked for the selected month. The registered daily chime schedules are identifi ed by colors and shown on the calendar. Click 5 Temporarily stored to save the current setting results temporarily. If you wish to cancel the setting results you have made, * click a title in the table of contents or “Refresh” in the web browser menu. When the settings on this window have fi nished, update 6 the system from [Updating the system]. (→P. 35) H I J
29 GETTING STARTED USING THE SYSTEM APPENDIX SETTING THE SYSTEM H Settings on [Weekly schedule] setting window Select either [Every week] or [Every other week].1) Set the schedule start and end dates.2) The monthly calendar is displayed by clicking * Refer calendar and you can select the start and end dates. If necessary, you can change the month by clicking * or . Set one of the registered daily chime schedules or no 3) schedule to each day of the week. (Select one from the pull-down menu.) I Settings on [Individual schedule] setting window Set an individual schedule to the target date. [Individual schedule] setting window will not open if you * have not selected the target date on the calendar in the [Chime schedule setting] window. If necessary, you can change the date by clicking 1) or repeatedly. [Daily chime schedule]: 2) Select one of the registered daily chime schedules or no schedule (to register a new schedule), from the pull- down menu. If necessary, modify a registered schedule or register a 3) new schedule. To register a new schedule: • Click Add. Another window opens. In this window, you can set [Chime time], [Sound source], [Zone number] and [Chime priority]. When the settings have fi nished, click Close to close this window. In the previous window, the added program is displayed in the list. Repeat this procedure to add more programs. * To modify a registered schedule:• Check the program you wish to modify, and then click Edit . Another window opens. Change the settings in this window. When fi nished modifying, click Close to close this window. You can also modify the registered schedule by * adding new program(s) or deleting program(s). (To delete, check the target program(s) in the list and then click Delete .) When modifi ed, [Daily chime schedule] changes to * “Individual schedule”. To delete a registered schedule: • Select “None” from the pull-down menu of [Daily chime schedule]. J Downloading chime schedule data You can store the chime schedule setting data in CSV format onto a PC. The data includes the transfer schedule setting (→P. 30) * data along with the chime schedule setting data. Registering daily transfer schedule [Transfer setting – Registering daily transfer schedule] You can set the schedule for transferring calls to other master stations in your site or remote sites automatically. The schedules registered on this setting are used when making a transfer setting on a master station. Up to 2 daily schedules can be registered. Click 1 Registering daily transfer schedule in the table of contents. [Schedule number]: 2 Select the schedule number DT1 or DT2 from the pull-down menu. [Schedule name]: 3 Enter the name of daily schedule. [Call transfer time]: 4 Set the [Start time (hour and minute)] and [End time (hour and minute)] of transferring. Click 5 Temporarily stored to save the current setting results temporarily. If you wish to cancel the setting results you have made, * click a title in the table of contents or “Refresh” in the web browser menu.
30 Setting transfer schedule [Transfer setting – Transfer schedule setting] You can set a weekly transfer schedule and individual daily schedule. The settings can be made 1 year ahead. * Click 1 Transfer schedule setting in the table of contents. Make the settings by clicking 2 Weekly schedule and Individual schedule respectively to open the corresponding window. Individual schedule* should be clicked after the target date is clicked on the calendar. Make the settings in the displayed window(s). 3 See the detailed instructions for K or L on the right column of this page. After the setting is fi nished on the corresponding 4 window, click Close to close the window. Calendar and setting status can be checked for the selected month. The registered daily transfer schedules are identifi ed by colors and shown on the calendar. Click 5 Temporarily stored to save the current setting results temporarily. If you wish to cancel the setting results you have made, * click a title in the table of contents or “Refresh” in the web browser menu. When the settings on this window have fi nished, update 6 the system from [Updating the system]. (→P. 35) K Settings on [Weekly schedule] setting window Select either [Every week] or [Every other week].1) Set the schedule start and end dates.2) The monthly calendar is displayed by clicking * Refer calendar and you can select the start and end dates. If necessary, you can change the month by clicking * or . Set one of the registered daily transfer schedules or no 3) schedule to each day of the week. (Select one from the pull-down menu.) L Settings on [Individual schedule] setting window Set an individual schedule to the target date. [Individual schedule] setting window will not open if you * have not selected the target date on the calendar in the [Transfer schedule setting] window. If necessary, you can change the date by clicking 1) or repeatedly. [Daily transfer schedule]: 2) Select either of the registered daily schedules (DT1 or DT2) or no schedule from the pull-down menu. [Call transfer time]: 3) When “DT1” or “DT2” is selected:• The call transfer time is automatically entered. If necessary, change the [Start time (hour and minute)] and [End time (hour and minute)] of transferring manually. When no schedule is selected: • Enter the call transfer time manually. When the time is entered or changed manually, [Daily * transfer schedule] changes to “Individual schedule”. K L