FK1721 A P0311 OQ GT-AC Access Control keypad Module Module clavier à codes rétro-éclairé GH / GT-Codeschlossmodul Módulo de teclado de control de acceso Codeklavier-module INSTALLATION & OPERATION MANUAL NOTICE D'INSTALLATION ET D'UTILISATION INSTALLATIONS- UND BEDIENUNGSANLEITUNG MANUAL DE INSTALACIÓN Y USO INSTALLATIE & GEBRUIKSHANDLEIDING GT-AC
2 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 2930 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 5960 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 8990 91 92 93 94 95 96 97 98 99 Registered User Code List / Liste des codes utilisateur programmés / Liste der registrierten Zugangscodes Lista de códigos de los usuarios registrados / Lijst Codes Geregistreerde Gebruikers group 1 / groupe 1 / gruppe 1 / grupo 1 / groep 1group 2 / groupe 2 / gruppe 2 / grupo 2 / groep 2 RECORD OF SETTINGS AND REGISTRATION DETAILS (Please make sure to write down your settings below.) AIDE MEMOIRE DES PROGRAMMATIONS ENREGISTREES (Faire en sorte de bien noter vos réglages ci-dessous.) VERZEICHNIS DER EINSTELLUNGEN UND REGISTRIERUNGSDETAILS (Bitte notieren Sie unten Ihre Einstellungen.) DATOS DE CONFIGURACIÓN Y DETALLES DE LOS REGISTROS (Asegúrese de apuntar los valores de ajuste abajo.) LIJST MET GEPROGRAMMEERDE INSTELLINGEN EN CODES (Zorg ervoor uw instellingen hieronder op te schrijven.) External output settingParamétrage de sortie externe Externer Ausgang Ajuste de la salida externa Activering Alarmuitgang Lockout Blocage Eingabe-Sperre Bloqueo Blokkering klavier Auto-relock Auto-reverrouillage Automatische Neuverriegelung Re-bloqueo automático Automatische hersluiting Timer-linked unlocking Déverrouillage lié à l'horloge Timergesteuerte Entriegelung Desbloqueo conectado al temporizadorTijdsgebonden ontgrendeling Operation toneBip de fonctionnementSignaltöneTono de operaciónZoemer klavier Master code Code maître Mastercode Código maestro Hoofdcode Key illumination timeTemporisation d'éclairage Tastenbeleuchtungszeit Tiempo de encendido de las teclasVerlichtingsduur klaviersec/sek/seg Relay output timeTemporisation des relais Relais Ausgabezeit Tiempo de salida Relé Relais outputtijdRelay 1 Relais 1 Relais 1 Relé 1 Relais 1 sec/sek/seg Relay 2 Relais 2 Relais 2 Relé 2 Relais 2 sec/sek/seg ON EIN AANOFF AUS UIT ON EIN AANOFF AUS UIT ON EIN AANOFF AUS UIT ON EIN AANOFF AUS UIT 121&2
3 English English Nederlands Français Deutsch Español General Prohibitions Prohibition to Dismantle the Unit General Precautions WARNING (Negligence could result in death or serious injury to people) 1. Do not connect any non-specified power source to the V, V terminals, and do not install two power supplies in parallel to a single input. Fire, damage to the unit, or system malfunction could result. 2. The unit is not explosion-proof. Do not install or use near gases or flammable materials. Fire or explosion could result. 3. Do not dismantle or alter the unit. Fire or electric shock could result. 4. Do not allow the wires or DC output terminals to be shorted. Fire or electric shock could result. 5. The unit must be installed and wired by a qualified technician. CAUTION (Negligence could result in injury to people or damage to property) 1. When mounting the unit on a wall, install the unit in a convenient location, but not where it could be jarred or bumped. Injury could result. 2. Do not install or make any wire terminations while power supply is plugged in. It can cause electrical shock or damage to the unit. 3. Before turning on power, make sure wires are not crossed or shorted. Fire or electric shock could result. 4. Do not install the unit in any of the following locations. Fire, electric shock, or unit trouble could result. * Places subject to dust, oil, chemicals, hydrogen sulfide (hot spring). * Places subject to moisture and humidity extremes, such as bathroom, cellar, greenhouse, etc. * Places where the temperature is quite low, such as inside a refrigerated area or in front of air-conditioner. * Places subject to steam or smoke (near heating or cooking surfaces). * Where noise generating devices such as dimmer switches, invertor electrical appliances, are closeby. GENERAL PRECAUTIONS 1. This product, being a control unit of door release, should not be used as a crime-prevention device. 2. This product is weather-resistant, but do not spray high-pressure water on it. Unit trouble could result. 3. The product becomes inoperative during power failure. 4. As to other manufacturer's devices, such as sensor, door releases, timer, used with this system, comply with the Specifications and Warranty conditions manufacturers or venders present. 5. Keep the intercom wires more than 30 cm (12 inches) away from AC 100-240 V lines, particularly AC lines for invertor electrical appliances. Noise and malfunction could result. PRECAUTIONS RECORD OF SETTINGS AND REGISTRATION DETAILS …2 PRECAUTIONS …………………………………………… 3 PACKAGE CONTENTS …………………………………… 3 NAMES ……………………………………………………… 3 MOUNTING ………………………………………………… 4 MOUNTING/WIRING METHOD, WIRING DISTANCE …… 4FUNCTIONS SETTING UP ……………………………… 6 OPERATIONS …………………………………………… 10 TECHNICAL PRECAUTIONS ………………………… 10 SPECIFICATIONS ……………………………………… 10 WARRANTY ……………………………………………… 10 CONTENTS UnitInstallation & operation manual PACKAGE CONTENTSNAMES 1 2 31 LED indicator (Orange) 2 LED indicator (Green) 3 Keys (Yellow)
4 English Nederlands Français Deutsch Español MOUNTING 1. Fix the mounting bracket to the back (or surface-mount) box. 2. Connect the wires to the unit. 3. Mount GT-AC to the front frame. • Mount GT-AC from behind the front frame. • Insert the notch into the slots on both sides. 4. Options a.Rain hood b.Hooded surface-mount box c.Surface-mount box * For details on mounting panels and modules other than the GT-AC, refer to the GF, GH or GT Installation and Operation Manual. 32 1 4 to GT-AC to GT-AC MOUNTING/WIRING METHOD, WIRING DISTANCE Electric door strike Electromagnetic door lockAutomatic gate Request to exit/entry button Relay Relay Request to exit/entry button Timer Power supply or C B A D 2 22 2 2 2 Power supplydiameter 0.65 - 1.0 mm (22-18AWG) A AC/DC12 ~ 18V(Less than)100m (330') AC/DC18 ~ 24V 300m (980') B-300m (980') C- 300m (980') D The connection distance will depend on the specifications of the electric door strike, relays or Electromagnetic door lock to be connected. To determine the operating range, please refer to the specifications of each terminal. (*1) Use a separate power supply for the GT-AC, not the ones used to power the system. (*2) Two relays can be activated from GT-AC. However, only one relay can be activated from a residential station. (Wiring distance) The illustrations below use the GH system.
5 English Nederlands Français Deutsch Español TCNO1C1NC1NO2C2NC2PB2PB1V V TCNO1C1NC1PB2PB1 R1 R2ELB ELC ELMRY RY R1 R2EL EL +RY RY V VNO2C2NC2 R1 R2ELB ELC ELMRY RY R1 R2 ELB ELC ELMRY RY R1 R2EL EL +RY Alarm, Security Only connecting to the terminal of relay 2 is possible. External output C2 NO2 Power supply (For GT-AC only) Rating Between 12 and 24V AC Between 12 and 24V DC Automatic gate TimerFor relay 2 Request to exit/entry button For relay 1 Request to exit/entry button 2 NP 2 NP 2 NP 2 NP2 NP Electric door strike 2 NP AC transformer Power supply (For GT-AC only)Request to exit/entry button (push button, etc.) 2 NP2 NP2 NP Back view of GT-AC (*1) The relay operating time of GT-DA(-L), GH-DA/A, GF- DA/B is different from that of GT-AC. Electromagnetic door lock Power supply Power supply (For GT-AC only)Request to exit/entry button (push button, etc.) N.C C PB2 ・ To setVJG "auto-relock" / "External output by forced entry" function a sensor (locally avallable) is required. ・ The request to exit/entry button for relay 2 cannot be used when the "auto-relock" / "External out put by forced entry" function are set. Auto-relock/External out put by forced entry (sensor connection is required) Electric door strike AC transformer Terminal names Relay 1: Automatic gate (N/O contact), Relay 2: Electric door strike (N/O contact) Connection of Relay 1 (N/O contact) only Connection of Relay 1 (N/C contact) only GH-DA/A GF-DA/BGH-DA/A GT-DA(-L), GT-DA(-L), GT-DA(-L), GH-DA/A GF-DA/B TCNO1C1NC1PB2PB1V VNO2C2NC2 PS 2 NP2 NP2 NP GT-AC GT-AC GT-AC * The connection with N/C contacts is not available for GF-DA/B. or or *1 TCNO1C1NC1NO2C2NC2PB2PB1V V N/C contact Power supplyUser group1 relay 1 User group2 relay 2 Request to exit/entry button 1Request to exit/entry button 2Common TimerN/C contact N/O contact N/O contact Power supply Between 12 and 24V AC Between 12 and 24V DC Request to exit/entry button ・ Timer ・ Minimum overload :100mV DC, 0.1mA or below・ Contact capacity: 30V DC, 0.1A or aboveRelay 24V DC, 3A or below (resistive load) 1A or below (inductive load) 24V AC, 3A or below (resistive load) 1A or below (inductive load) ・ Minimum overload :5V DC, 100mA or above *1
6 English Nederlands Français Deutsch Español FUNCTIONSSETTING UP This section explains the settings of each function, including the master code for management, the user code for unlocking, the buzzer and the LEDs. About the setting mode: Enter master code twice to switch to the setting mode, and enter the following setting code to perform the settings for the desired function. After settings have been made, enter the following setting codes to continue the setting operation. Press to exit the setting mode. Setting items Allowable setting range Default valueSetting code Setting the code length Change the length of the master code and the user code. )They both must be the same length. 4, 5, or 6 digits 4 digits Setting the master code Enter a master code using between 4 and 6 digits (alpha or numeric) to switch to the setting mode. ) The number of digits in the code can be set by setting the code length. 1 Valid keys: 0 - 9, A, B1234 Setting the code for user group 1 Set the unlocking code for user group 1. ) The number of digits in the code can be set by setting the code length. Number of codes: 60 Valid keys: 0 - 9, A, B- - Setting the code for user group 2 Set the unlocking code for user group 2. ) The number of digits in the code can be set by setting the code length. Number of codes: 40 Valid keys: 0 - 9, A, B- - Setting the key illumination time Set the length of time that the keys will be lit up after they are pressed. Illumination time: 10 to 99 seconds, or continually lit10 Sec. Setting the relay 1 output time Set the output time of relay 1. Output time: 1 to 99 seconds, or latched3 Sec. Setting the relay 2 output time Set the output time of relay 2. Output time: 1 to 99 seconds, or latched3 Sec. Reset Settings Return all the settings to their default values. -- External output setting The alarm or security system connected to the terminal of relay 2 will be activated when the "Lockout" * or the forced entry* is carried out. * "Lockout": Refer to VIII below. *Forced entry: This function is linked with the door open/close sensor (N.C.) which is connected to PB2 and C, and carried out when opening the door without activating this unit. (For example, entry in an improper manner, manual unlock, etc.) ) If there is a way to open the door without activating this unit, such as manual unlock, do not make the external output setting for the forced entry. · OFF · During Lockout · During forced entry output · During lockout and forced entry output OFF Lockout If several incorrect access codes are attempted, the code input function is disabled for a programmed period of time. · When "Lockout" is activated, the LED (Orange) indicator and the keypad blink, and the buzzer sounds for 3 seconds. This is just a sound to inform you that the function has been activated. It is not a warning sound. If you want a warning to be sounded, please use the external output function to activate a commercially-available alarm device. · The unlock function will work when the request to exit/entry button is pushed, even while the "Lockout" function is operating. ON/OFF Invalid number of times: 10 to 99 times Invalid time: 10 to 99 secondsOFF Auto-relock (Anti-tailgate) After the door has been linked to the door open/close sensor (N/C), and unlocked, it will relock itself one second after being closed, thus preventing the entry of an unauthorized third party. )1 ON/OFF OFF Timer-linked unlocking setting The system can be set to unlock the door by pressing the key within the set time and linking it to the external timer (N/O). The operations for the LEDs and the buzzer after unlocking are the same as those used to perform user code unlocking. When the door is linked to the timer, unlocking can be performed using the user code and the request to exit/entry button. When latch output is performed for the relay settings, the relay turns ON/OFF every time the key is pressed. Linked relay: relay 1 relay 2 relay 1 and 2 0 key illumination: ON/OFFLinked relay: relay 1 0 key illumination: OFF Operation tone settings Set the tone heard when the keypad is being used to ON/OFF. ON/OFF ON • The setting can be saved even when the power is off. • The system cannot be switched to the setting mode while the relay is unlocked. • When the setting mode has been activated and no operations are performed for approximately 120 seconds, the system will exit the setting mode. (If a key is pressed during that time, the timer will start over.) • Neither the request to exit/entry button nor the timer-linked unlocking key can be operated, and unlocking using the user code cannot be performed while the setting mode is activated. • The volume (the check tone, operation tone, etc.) from the main unit may become lower according to the mounting status. 1 : When the auto-relock is used, the request to exit/entry button for relay 2 cannot be used. The output of relay 2 is only possible when user code unlocking is performed.
7 English Nederlands Français Deutsch Español Input the master code twice. (Default: ) The result of each operation is indicated by the lighting up of the LED indicators on the upper section of the unit, and by the sounding of the buzzer. - When the key is pressed, the green LED lights up, the buzzer beeps twice, and the system exits the setting mode. (If the key is included in the user code and the master code, the system does not exit the setting mode.) - You can continue the setting up operation by entering an arbitrary setting code. (orange) Illumination(green) Blinking Orange (L)Green (R) Bleep, Bleep Indicator goes outBlinking Bleep, Bleep Inputting of user number (ex.: 01) Inputting of code (ex.: 1006) * Numbers 0 - 9 and the letters A and B can be used Inputting of user number (ex.: 60) Inputting of code (ex.: 04B2) * Numbers 0 - 9 and the letters A and B can be used · To make the set user code invalid, press 0000 (when 4 digits are used), 00000 (when 5 digits are used), or 000000 (when 6 digits are used). Code numbers which contain only "0" cannot be set as user codes. · As the factory pre-setting master code is 1234, 1234 (when 4 digits are used), 12345 (when 5 digits are used), and 123456 (when 6 digits are used) cannot be set as user codes. · Do not set simple codes, such as 1111. * The same code cannot be set for both the user code and the master code. The previously set code has priority. Setting the code 00 - 59 60 - 99 group 2 Blinks twiceBlinking Illumination Illumination IlluminationBlinks twice Blinking Illumination Illumination When a user code that has already been set is selectedWhen a user code that has already been set is selected Blinking Illumination Blinking group 1 Bleep, BleepBleepBleep, Bleep Bleep BeepBeep Illumination Blinking Setting the master code (Default 9æ1234) Inputting of new master code (ex.: 4321) Input the setting code. · Please note that the shift to the setting mode can be performed during timer-linked unlocking. However, if " " is included in the master code, the door will be unlocked, and the shift to the setting mode will not be able to be performed. · The same code cannot be set for both the user code and the master code (the previously set code has priority). · Do not set simple codes, such as 1111. · We recommend that you change the default master code. Illumination Blinking Beep Bleep Illumination Blinking · The set code will be saved in m em or y , ev en i f the c ode l ength i s c hanged. H ow ev er , c odes of di ffer ent l engths c annot be us ed. · W hen the c ode l ength has been c hanged, the m as ter c ode r etur ns to the defaul t v al ue ( i f the num ber of di gi ts i n the c ode i s 4, 5, or 6, the m as ter c ode i s 1234, 12345, or 123456 r es pec ti v el y ) . Inputting of code length (ex.: 5 digits)4, 5, or 6 digits Input the setting code. Setting the code length (Default: 4 digits) Illumination Blinking Beep Bleep
8 English Nederlands Français Deutsch Español External output setting (Default: OFF) Input the setting code. Illumination IlluminationBlinks three times Blinking OFFOFFDuring lockoutand forcedentry outputDuringLockout During forcedentry outputDuring lockout and forced entry output · If the pow er i s tur ned off and the , , and k ey s ar e pr es s ed s i m ul taneous l y w hi l e the unl oc k 1 i nput s tatus i s ac ti v e ( s hor t c i r c ui t betw een ter m i nal s PB1 and C ) , the s etti ngs c an be r etur ned to thei r defaul t v al ues by tur ni ng the pow er bac k on and pr es s i ng the , , and k ey s s i m ul taneous l y for 3 seconds.· W hen s etti ng the ex ter nal output, do not s et the r el ay 2 output to be l atc hed. Input the setting code. Reset Settings Illumination Blinking Illumination Blinking(orange) Illumination(green) Blinking Input the master code twice. (Default : ) During Lockout During forced entry output Bleep, Bleep, BeepBeep Bleep, Bleep BleepBleep Inputting of relay output time (ex.: 99 seconds) 01 - 99 Latched ( *) : 00 · ( *) If the latched status has been set and the door is unlocked, it will not be locked again until the user code is entered (or the request to exit/entry button is pressed, or the key is pressed while timer-linked unlocking is set). · When the door is unlocked during relay outputting (including when latched), the system cannot be switched to the setting mode. When setting relay 1When setting relay 1 When setting relay 2When setting relay 2 Setting the relay output time (Default: 3 Sec.) Input the setting code. Input the setting code. Illumination Blinking Illumination Blinking Beep Bleep Setting the key illumination time (Default: 10 Sec.) Input the setting code. Inputting of illumination time (ex.: 20 seconds) 10 - 99 Indicator is lit up at all times: 00 Illumination Blinking Illumination Blinking Beep Bleep - When the key is pressed, the green LED lights up, the buzzer beeps twice, and the system exits the setting mode. (If the key is included in the user code and the master code, the system does not exit the setting mode.) - You can continue the setting up operation by entering an arbitrary setting code. Indicator goes outBlinking Bleep, Bleep
9 English Nederlands Français Deutsch Español · When the relay 1 output time is set to latched output, the auto-relock function is disabled. · When the auto-relock function is turned on, the unlock function of the request to exit/entry button of relay 2 is disabled.· If the 0 key illumination function is turned on while the timer is on, only the 0 key illumination will light up, even if the "key illumination time setting" is set to "Indicator is continually lit". OFFONOFF ON OFFOFF ONONOperation tone OFFOperation tone ONOperation tone OFFOperation tone ONRelays 1 and 2 are both linkedRelays 1 and 2 are both linkedOnly relay 1 is linked Input the setting code. Input the setting code. Input the setting code. Input the setting code. Lockout (Default: OFF) Auto-relock (Anti-tailgate) (Default: OFF) Timer-linked unlocking setting (Default: relay 1, OFF) Operation sound settings (Default: ON) 0 key illumination ONwhile timer is on0 key illumination OFFwhile timer is on0 key illumination ON while timer is on 0 key illumination OFF while timer is on Inputting the number of operations (ex. 9æ10 times) 10 -99 Inputting length of time in "Lockout" mode (Ex.: 10 seconds) 10 - 99 Input the master code twice. (Default : ) Only relay 1 is linkedOnly relay 2 is linkedOnly relay 2 is linked Beep (orange) Illumination(green) Blinking Bleep, Bleep Illumination Blinking Illumination Blinking Illumination BlinkingIllumination Blinking Bleep Bleep BleepBleep Illumination Blinking Illumination Blinking Illumination Blinking Bleep BeepBeep Illumination Blinking Illumination Blinking Bleep Illumination Blinking BleepIllumination Blinking Beep Illumination Blinking Beep - When the key is pressed, the green LED lights up, the buzzer beeps twice, and the system exits the setting mode. (If the key is included in the user code and the master code, the system does not exit the setting mode.) - You can continue the setting up operation by entering an arbitrary setting code. Indicator goes outBlinking Bleep, Bleep
10 English Nederlands Français Deutsch Español OPERATIONS A. Unlocking of user code When the registered user code has been input using the keypad (between 4 and 6 digits), the LED indicator (group 1: orange, group 2: green) lights up, the buzzer sounds, and the electric door strike is unlocked. Orange LED lights up (during relay1 operation)Green LED lights up (during relay2 operation) ex.): group 1 1006group 2 04B2 BeepBeep • The time interval during which the button must be pressed is approximately 10 seconds. If the time interval exceeds approximately 10 seconds, the input value will be cleared. • If you make a mistake when inputting the user code, input the user code again. • When the "Lockout" function has been set, the release function is locked and the input operation is disabled for the specified time (10 ~ 99 seconds) if invalid codes are input a set number of times (10 ~ 99 times). (Reference: "Lockout".) During this time, the key illumination will blink 4 times, the LED (orange) indicator will blink for the set deactivation time, and the buzzer will sound for approximately 3 seconds. B. Timer-linked unlocking When the timer-linked unlocking function is active, the door can be unlocked by pressing the key during the set time, while the timer is linked. The key illumination lights up when the timer is activated by performing the setting. C. Unlocking using the request to exit/entry button When leaving the premises, you can activate the electric door strike by pressing the request to exit/entry button connected to the unit. Pressing request to exit/entry button 1 releases relay 1, and pressing request to exit/ entry button 2 releases relay 2. • When the door is unlocked using the request to exit/ entry button, the LED will not light up and the buzzer will not sound. TECHNICAL PRECAUTIONS • Operating temperature: Between -10°C and 60°C (14˚F to 140˚F) • Cleaning: Clean the unit with a soft cloth dampened with a neutral household cleanser. Do not use any abrasive cleanser or cloths. • The unit is weather resistant. However do not spray high pressure water on access control keypad directly. Excessive moisture may cause problems with the unit. • Press and release the ,,, and keys simultaneously when this unit does not work. )The LEDs (orange and green) will blink and the buzzer will sound, and then resetting will take place. (The settings do not return to their default values.) • If resetting does not work, contact the service technician who installed the unit. SPECIFICATIONS • Power supply: 12 ~ 24V AC 12 ~ 24V DC • Power consumption: DC: Max. 70mA AC: Max. 100mA • Dimensions: 95.2(H) × 110(W) × 29.3(D)mm H 3-2/3” x W 4-5/16” x D 1-1/8” • Weight: approx. 330g (0.72lbs) • Number of relay circuits: 2 • Relay contact: N/O, N/C • Relay contact capacity: 24V DC, 3A (resistive load) 1A (inductive load) 24V AC, 3A (resistive load) 1A (inductive load) WARRANTY Aiphone warrants its products to be free from defects of material and workmanship under normal use and service for a period of one year after delivery to the ultimate user and will repair free of charge or replace at no charge, should it become defective upon which examination shall disclose to be defective and under warranty. Aiphone reserves unto itself the sole right to make the final decision whether there is a defect in materials and/or workmanship; and whether or not the product is within the warranty. This warranty shall not apply to any Aiphone product which has been subject to misuse, neglect, accident, or to use in violation of instructions furnished, nor extended to units which have been repaired or altered outside of the factory. This warranty does not cover batteries or damage caused by batteries used in connection with the unit. This warranty covers bench repairs only, and any repairs must be made at the shop or place designated in writing by Aiphone. Aiphone will not be responsible for any costs incurred involving on site service calls. Aiphone will not provide compensation for any loss or damage incurred by the breakdown or malfunction of its products during use, or for any consequent inconvenience or losses that may result. FCC This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.