    							FK1721 A P0311 OQ
    GT-AC
    Access Control keypad Module
    Module clavier à codes rétro-éclairé
    GH / GT-Codeschlossmodul
    Módulo de teclado de control de acceso
    Codeklavier-module
    INSTALLATION & OPERATION MANUAL
    NOTICE D'INSTALLATION ET D'UTILISATION
    INSTALLATIONS- UND BEDIENUNGSANLEITUNG
    MANUAL DE INSTALACIÓN Y USO
    INSTALLATIE & GEBRUIKSHANDLEIDING
    GT-AC 
    						
    							2
    00
    01
    02
    03
    04
    05
    06
    07
    08
    09
    10
    11
    12
    13
    14
    15
    16
    17
    18
    19
    20
    21
    22
    23
    24
    25
    26
    27
    28
    2930
    31
    32
    33
    34
    35
    36
    37
    38
    39
    40
    41
    42
    43
    44
    45
    46
    47
    48
    49
    50
    51
    52
    53
    54
    55
    56
    57
    58
    5960
    61
    62
    63
    64
    65
    66
    67
    68
    69
    70
    71
    72
    73
    74
    75
    76
    77
    78
    79
    80
    81
    82
    83
    84
    85
    86
    87
    88
    8990
    91
    92
    93
    94
    95
    96
    97
    98
    99
    Registered User Code List / Liste des codes utilisateur programmés / Liste der registrierten Zugangscodes 
     Lista de códigos de los usuarios registrados / Lijst Codes Geregistreerde Gebruikers
    group 1 / groupe 1 / gruppe 1 / grupo 1 / groep 1group 2 / groupe 2 / gruppe 2 / grupo 2 / groep 2
    RECORD OF SETTINGS AND REGISTRATION DETAILS (Please make sure to write down your settings below.)
    AIDE MEMOIRE DES PROGRAMMATIONS ENREGISTREES (Faire en sorte de bien noter vos réglages ci-dessous.)
    VERZEICHNIS DER EINSTELLUNGEN UND REGISTRIERUNGSDETAILS (Bitte notieren Sie unten Ihre Einstellungen.)
    DATOS DE CONFIGURACIÓN Y DETALLES DE LOS REGISTROS (Asegúrese de apuntar los valores de ajuste abajo.)
    LIJST MET GEPROGRAMMEERDE INSTELLINGEN EN CODES (Zorg ervoor uw instellingen hieronder op te schrijven.)
    External output settingParamétrage de sortie externe
    Externer Ausgang
    Ajuste de la salida externa
    Activering Alarmuitgang
    Lockout
    Blocage
    Eingabe-Sperre
    Bloqueo
    Blokkering klavier
    Auto-relock
    Auto-reverrouillage
    Automatische Neuverriegelung
    Re-bloqueo automático
    Automatische hersluiting
    Timer-linked unlocking
    Déverrouillage lié à l'horloge
    Timergesteuerte Entriegelung
    Desbloqueo conectado al temporizadorTijdsgebonden ontgrendeling
    Operation toneBip de fonctionnementSignaltöneTono de operaciónZoemer klavier
    Master code
    Code maître 
    Mastercode
    Código maestro
    Hoofdcode
    Key illumination timeTemporisation d'éclairage
    Tastenbeleuchtungszeit
    Tiempo de encendido de las teclasVerlichtingsduur klaviersec/sek/seg
    Relay output timeTemporisation des relais
    Relais Ausgabezeit
    Tiempo de salida Relé
    Relais outputtijdRelay 1
    Relais 1
    Relais 1
    Relé 1
    Relais 1
    sec/sek/seg
    Relay 2
    Relais 2
    Relais 2
    Relé 2
    Relais 2
    sec/sek/seg
    ON
    EIN
    AANOFF
    AUS
    UIT
    ON
    EIN
    AANOFF
    AUS
    UIT
    ON
    EIN
    AANOFF
    AUS
    UIT
    ON
    EIN
    AANOFF
    AUS
    UIT
    121&2 
    						
    							3
    English
    English
    Nederlands
    Français
    Deutsch
    Español
    General Prohibitions  Prohibition to Dismantle the Unit
    General Precautions
    WARNING
    (Negligence could result in death or serious injury to 
    people)
    1.  Do not connect any non-specified power source to the 
    V, V terminals, and do not install two power supplies in 
    parallel to a single input. Fire, damage to the unit, or 
    system malfunction could result.
    2.  The unit is not explosion-proof. Do not install or use 
    near gases or flammable materials. Fire or explosion 
    could result.
    3.  Do not dismantle or alter the unit. Fire or electric shock 
    could result.
    4.  Do not allow the wires or DC output terminals to be 
    shorted. Fire or electric shock could result.
    5.  The unit must be installed and wired by a qualified 
    technician.
    CAUTION
    (Negligence could result in injury to people or damage 
    to property)
    1.  When mounting the unit on a wall, install the unit in a 
    convenient location, but not where it could be jarred or 
    bumped. Injury could result.
    2.  Do not install or make any wire terminations while 
    power supply is plugged in. It can cause electrical 
    shock or damage to the unit.
    3.  Before turning on power, make sure wires are not 
    crossed or shorted. Fire or electric shock could result.
    4.  Do not install the unit in any of the following locations. 
    Fire, electric shock, or unit trouble could result.
      *  Places subject to dust, oil, chemicals, hydrogen sulfide 
    (hot spring).
      *  Places subject to moisture and humidity extremes, 
    such as bathroom, cellar, greenhouse, etc.
      *  Places where the temperature is quite low, such as 
    inside a refrigerated area or in front of air-conditioner.
      *  Places subject to steam or smoke (near heating or 
    cooking surfaces).
      *  Where noise generating devices such as dimmer 
    switches, invertor electrical appliances, are closeby.
    GENERAL PRECAUTIONS
    1.  This product, being a control unit of door release, 
    should not be used as a crime-prevention device.
    2.  This product is weather-resistant, but do not spray 
    high-pressure water on it. Unit trouble could result.
    3.  The product becomes inoperative during power failure.
    4.  As to other manufacturer's devices, such as sensor, 
    door releases, timer, used with this system, comply 
    with the Specifications and Warranty conditions 
    manufacturers or venders present.
    5.  Keep the intercom wires more than 30 cm (12 inches) 
    away from AC 100-240 V lines, particularly AC lines for 
    invertor electrical appliances. Noise and malfunction 
    could result.
    PRECAUTIONS
    RECORD OF SETTINGS AND REGISTRATION DETAILS …2
    PRECAUTIONS …………………………………………… 3
    PACKAGE CONTENTS  …………………………………… 3
    NAMES ……………………………………………………… 3
    MOUNTING ………………………………………………… 4
    MOUNTING/WIRING METHOD, WIRING DISTANCE …… 4FUNCTIONS
    SETTING UP  ……………………………… 6
    OPERATIONS …………………………………………… 10
    TECHNICAL PRECAUTIONS  ………………………… 10
    SPECIFICATIONS ……………………………………… 10
    WARRANTY ……………………………………………… 10
    CONTENTS
    UnitInstallation &  
    operation manual
    PACKAGE CONTENTSNAMES
    1
    2
    31   LED indicator 
    (Orange)
    2   LED indicator 
    (Green)
    3   Keys (Yellow) 
    						
    							4
    English
    Nederlands
    Français
    Deutsch
    Español
    MOUNTING
    1.  Fix the mounting bracket to the back (or surface-mount) 
    box.
    2.  Connect the wires to the unit.
    3.  Mount GT-AC to the front frame.
      • Mount GT-AC from behind the front frame.
     •  Insert the notch into the slots on both sides.
    4. Options
    a.Rain hood
    b.Hooded surface-mount box
    c.Surface-mount box
    * For details on mounting panels and modules other than 
    the GT-AC, refer to the GF, GH or GT Installation and 
    Operation Manual.
    32
    1
    4
    to GT-AC
    to GT-AC
    MOUNTING/WIRING METHOD, WIRING DISTANCE
    Electric
    door strike Electromagnetic
    door lockAutomatic gate
    Request to exit/entry 
    button Relay
    Relay
    Request to exit/entry 
    button
    Timer Power supply
    or
    C B A D
    2
    22
    2
    2 2
    Power supplydiameter 0.65 - 1.0 mm (22-18AWG)
    A
    AC/DC12 ~ 18V(Less than)100m (330')
    AC/DC18 ~ 24V
    300m (980')
    B-300m (980')
    C- 300m (980')
    D
    The connection distance will depend on 
    the specifications of the electric door strike, 
    relays or Electromagnetic door lock to be 
    connected. To determine the operating range, 
    please refer to the specifications of each 
    terminal.
    (*1)  Use a separate power supply for the GT-AC, not 
    the ones used to power the system.
    (*2)  Two relays can be activated from GT-AC. 
    However, only one relay can be activated from a  
    residential station.
    (Wiring distance) The illustrations below use the GH system. 
    						
    							5
    English
    Nederlands
    Français
    Deutsch
    Español
    TCNO1C1NC1NO2C2NC2PB2PB1V V
    TCNO1C1NC1PB2PB1
    R1 R2ELB ELC ELMRY RY R1 R2EL EL +RY RY
    V VNO2C2NC2
    R1 R2ELB ELC ELMRY RY
    R1 R2
    ELB ELC ELMRY RY R1 R2EL EL +RY
    Alarm, Security Only connecting to the terminal 
    of relay 2 is possible. External output
    C2
    NO2
    Power supply
    (For GT-AC only)
    Rating
    Between 12 and 24V AC
    Between 12 and 24V DC
    Automatic gate
    TimerFor relay 2 
    Request to 
    exit/entry button For relay 1 
    Request to 
    exit/entry button
    2
    NP
    2
    NP
    2
    NP
    2
    NP2
    NP
    Electric door strike
    2
    NP
    AC transformer
    Power supply
    (For GT-AC only)Request to exit/entry button
    (push button, etc.)
    2
    NP2
    NP2
    NP
    Back view of GT-AC
    (*1) The relay operating time of GT-DA(-L), GH-DA/A, GF-
    DA/B is different from that of GT-AC.
    Electromagnetic door lock
    Power supply
    Power supply
    (For GT-AC only)Request to exit/entry button
    (push button, etc.)
    N.C
    C
    PB2
    ・
    To setVJG "auto-relock" / "External output by forced entry" function a 
    sensor (locally avallable) is required.
    ・
    The request to exit/entry button for relay 2 cannot be used when the 
    "auto-relock" / "External out put by forced entry" function are set. 
    Auto-relock/External out put by forced entry  
    (sensor connection is required)
    Electric door strike
    AC transformer
    Terminal names
    Relay 1: Automatic gate (N/O contact), Relay 
    2: Electric door strike (N/O contact) Connection of Relay 
    1 (N/O contact) only
    Connection of Relay 
    1 (N/C contact) only
    GH-DA/A GF-DA/BGH-DA/A GT-DA(-L),
    GT-DA(-L), GT-DA(-L),
    GH-DA/A GF-DA/B
    TCNO1C1NC1PB2PB1V VNO2C2NC2
    PS
    2
    NP2
    NP2
    NP
    GT-AC
    GT-AC
    GT-AC
    * The connection with N/C contacts 
    is not available for GF-DA/B.
    or
    or
    *1
    TCNO1C1NC1NO2C2NC2PB2PB1V V
    N/C contact
    Power supplyUser group1 relay 1 User group2 relay 2
    Request to 
    exit/entry
    button 1Request to
    exit/entry
    button 2Common TimerN/C contact
    N/O contact N/O contact
    Power supply
    Between 12 and 24V AC
    Between 12 and 24V DC
    Request to exit/entry button ・
    Timer
    ・
    Minimum overload :100mV DC, 0.1mA or below・
    Contact capacity: 30V DC, 0.1A or aboveRelay
    24V DC, 3A or below (resistive load) 
      1A or below (inductive load)
    24V AC, 3A or below (resistive load) 
      1A or below (inductive load)
    ・
    Minimum overload :5V DC, 100mA or above
    *1 
    						
    							6
    English
    Nederlands
    Français
    Deutsch
    Español
    FUNCTIONSSETTING UP
    This section explains the settings of each function, including the master code for management, the user code for unlocking, the 
    buzzer and the LEDs. 
    About the setting mode:
    Enter master code twice to switch to the setting mode, and enter the following setting code to perform the settings 
    for the desired function. After settings have been made, enter the following setting codes to continue the setting 
    operation. Press 
     to exit the setting mode.
    Setting items Allowable setting range  Default valueSetting code
      Setting the code length
    Change the length of the master code and the user code. )They both must be the same length.
    4, 5, or 6 digits 4 digits
      Setting the master code
    Enter a master code using between 4 and 6 digits (alpha or numeric) to 
    switch to the setting mode. 
    ) The number of digits in the code can be set by setting the code length.
    1
    Valid keys: 0 - 9, A, B1234
      Setting the code for user group 1
    Set the unlocking code for user group 1. ) The number of digits in the code can be set by setting the code length.
    Number of codes: 60
    Valid keys: 0 - 9, A, B- - 
      Setting the code for user group 2
    Set the unlocking code for user group 2. ) The number of digits in the code can be set by setting the code length.
    Number of codes: 40
    Valid keys: 0 - 9, A, B- - 
      Setting the key illumination time
    Set the length of time that the keys will be lit up after they are pressed. 
    Illumination time: 10 to 99 
    seconds, or continually lit10 Sec.
      Setting the relay 1 output time
    Set the output time of relay 1.
    Output time: 1 to 99 
    seconds, or latched3 Sec.
      Setting the relay 2 output time
    Set the output time of relay 2.
    Output time: 1 to 99 
    seconds, or latched3 Sec.
     Reset Settings
    Return all the settings to their default values.
    --
      External output setting
    The alarm or security system connected to the terminal of relay 2 will be 
    activated when the "Lockout" * or the forced entry* is carried out.   
    * "Lockout": Refer to VIII below. *Forced entry: This function is linked with 
    the door open/close sensor (N.C.) which is connected to PB2 and C, and 
    carried out when opening the door without activating this unit. (For example, 
    entry in an improper manner, manual unlock, etc.)
    ) If there is a way to open the door without activating this unit, such as 
    manual unlock, do not make the external output setting for the forced entry.  
    · OFF
    ·  During Lockout 
    ·  During forced entry output
    ·  
    During lockout and forced 
    entry output
    OFF
     Lockout
    If several incorrect access codes are attempted, the code input function is 
    disabled for a programmed period of time.
    ·   When "Lockout" is activated, the LED (Orange) indicator and the keypad 
    blink, and the buzzer sounds for 3 seconds. This is just a sound to inform 
    you that the function has been activated. It is not a warning sound. If you 
    want a warning to be sounded, please use the external output function to 
    activate a commercially-available alarm device.
    ·  The unlock function will work when the request to exit/entry button is 
    pushed, even while the "Lockout" function is operating.
    ON/OFF
    Invalid number of times:  
    10 to 99 times
    Invalid time:  
    10 to 99 secondsOFF
     Auto-relock (Anti-tailgate)
    After the door has been linked to the door open/close sensor (N/C), and 
    unlocked, it will relock itself one second after being closed, thus preventing 
    the entry of an unauthorized third party. 
    )1
    ON/OFF OFF
      Timer-linked unlocking setting
    The system can be set to unlock the door by pressing the  key within 
    the set time and linking it to the external timer (N/O). The operations for the 
    LEDs and the buzzer after unlocking are the same as those used to perform 
    user code unlocking. When the door is linked to the timer, unlocking can be 
    performed using the user code and the request to exit/entry button. When 
    latch output is performed for the relay settings, the relay turns ON/OFF 
    every time the 
     key is pressed.
    Linked relay: relay 1
    relay 2
    relay 1 and 2
    0 key illumination: ON/OFFLinked relay: relay 1
    0 key illumination: OFF
      Operation tone settings
    Set the tone heard when the keypad is being used to ON/OFF.
    ON/OFF ON
    •  The setting can be saved even when the power is off. 
    •  The system cannot be switched to the setting mode while the relay is unlocked.
    •  When the setting mode has been activated and no operations are performed for approximately 120 seconds, the system 
    will exit the setting mode. (If a key is pressed during that time, the timer will start over.)
    •  Neither the request to exit/entry button nor the timer-linked unlocking 
     key can be operated, and unlocking using the 
    user code cannot be performed while the setting mode is activated.
    •  The volume (the check tone, operation tone, etc.) from the main unit may become lower according to the mounting status.
    1 : When the auto-relock is used, the request to exit/entry button for relay 2 cannot be used. The output of relay 2 is 
    only possible when user code unlocking is performed. 
    						
    							7
    English
    Nederlands
    Français
    Deutsch
    Español
    Input the master code twice.
    (Default:                                                                )
    The result of each operation is indicated by the 
    lighting up of the LED indicators on the upper section 
    of the unit, and by the sounding of the buzzer.
    - 
    When the         key is pressed, the green LED lights up, the buzzer beeps twice, and the system exits the setting mode. 
    (If the         key is included in the user code and the master code, the system does not exit the setting mode.) 
    - You can continue the setting up operation by entering an arbitrary setting code.
    (orange)
    Illumination(green)
    Blinking
    Orange (L)Green (R)
    Bleep, Bleep
    Indicator 
    goes outBlinking
    Bleep,
    Bleep
    Inputting of user number (ex.:  01)
    Inputting of code (ex.: 1006)
    * Numbers 0 - 9 and the 
    letters A and B can be used
    Inputting of user number (ex.:  60)
    Inputting of code (ex.: 04B2)
    * Numbers 0 - 9 and the 
    letters A and B can be used
    ·  To make the set user code invalid, press 0000 (when 4 digits are 
    used), 00000 (when 5 digits are used), or 000000 (when 6 digits are 
    used). Code numbers which contain only "0" cannot be set as user 
    codes.
    ·  As the factory pre-setting master code is 1234, 1234 (when 4 digits 
    are used), 12345 (when 5 digits are used), and 123456 (when 6 
    digits are used) cannot be set as user codes.
    ·  Do not set simple codes, such as 1111.
    * The same code cannot be set for both the user code and the 
    master code. The previously set code has priority.
       Setting the code
    00 - 59 60 - 99
    group 2
    Blinks 
    twiceBlinking Illumination
    Illumination
    IlluminationBlinks 
    twice Blinking Illumination Illumination
    When a user code 
    that has already 
    been set is selectedWhen a user code 
    that has already 
    been set is selected
    Blinking Illumination Blinking
    group 1
    Bleep,
    BleepBleepBleep,
    Bleep Bleep
    BeepBeep
    Illumination Blinking
       Setting the master code
    (Default
    9æ1234)
    Inputting of new master code 
    (ex.:  4321)
    Input the setting code. 
    ·  Please note that the shift to the 
    setting mode can be performed 
    during timer-linked unlocking. 
    However, if "      " is included in 
    the master code, the door will 
    be unlocked, and the shift to 
    the setting mode will not be 
    able to be performed.
    ·  The same code cannot be set 
    for both the user code and the 
    master code (the previously set 
    code has priority).
    ·  Do not set simple codes, such 
    as 1111.
    ·  We recommend that you 
    change the default master 
    code.
    Illumination Blinking
    Beep
    Bleep
    Illumination Blinking
    ·  The set code will be saved in 
    m em or y , ev en i f the c ode l ength 
    i s  c hanged. H ow ev er , c odes  of 
    di ffer ent l engths  c annot be us ed.
    ·  W hen the c ode l ength has  been 
    c hanged, the m as ter  c ode r etur ns  
    to the defaul t v al ue ( i f the num ber  
    of di gi ts  i n the c ode i s  4, 5, or  6, 
    the m as ter  c ode i s  1234, 12345, 
    or  123456 r es pec ti v el y ) .
    Inputting of code length (ex.:  5 digits)4, 5, or 6 digits
    Input the setting code. 
       Setting the code length
    (Default: 4 digits)
    Illumination Blinking
    Beep
    Bleep 
    						
    							8
    English
    Nederlands
    Français
    Deutsch
    Español
       External output setting
    (Default: OFF)
    Input the setting code. 
    Illumination IlluminationBlinks three times Blinking
    OFFOFFDuring lockoutand forcedentry outputDuringLockout During forcedentry outputDuring lockout
    and forced
    entry output
    ·   If the pow er  i s  tur ned off and 
    the       ,       , and        k ey s  ar e 
    pr es s ed s i m ul taneous l y  w hi l e the 
    unl oc k  1 i nput s tatus  i s  ac ti v e 
    ( s hor t c i r c ui t betw een ter m i nal s  
    PB1 and C ) , the s etti ngs  c an be 
    r etur ned to thei r  defaul t v al ues  by  
    tur ni ng the pow er  bac k  on and 
    pr es s i ng the       ,       , and        
    k ey s  s i m ul taneous l y  for  3 
    seconds.·  W hen s etti ng the ex ter nal  output, 
    do not s et the r el ay  2 output to be 
    l atc hed. 
    Input the setting code. 
       Reset Settings
    Illumination Blinking Illumination Blinking(orange)
    Illumination(green)
    Blinking
    Input the master code twice.
    (Default :                                                                )
    During
    Lockout During forced
    entry output
    Bleep, Bleep, BeepBeep
    Bleep, Bleep
    BleepBleep
    Inputting of relay output time 
    (ex.: 99 seconds)
    01 - 99
    Latched (
    *) : 00
    ·  (
    *) If the latched status has 
    been set and the door is 
    unlocked, it will not be locked 
    again until the user code is 
    entered (or the request to 
    exit/entry button is pressed, or 
    the       key is pressed while 
    timer-linked unlocking is set).
    ·  When the door is unlocked 
    during relay outputting 
    (including when latched), the 
    system cannot be switched to 
    the setting mode.
    When setting relay 1When setting relay 1 When setting relay 2When setting relay 2
        Setting the relay output time
    (Default: 3 Sec.)
    Input the setting code.  Input the setting code. 
    Illumination Blinking Illumination Blinking
    Beep
    Bleep
       Setting the key illumination time
    (Default: 10 Sec.)
    Input the setting code. 
    Inputting of illumination time 
    (ex.: 20 seconds)
    10 - 99
    Indicator is lit up at all times: 00
    Illumination Blinking Illumination Blinking
    Beep
    Bleep
    - When the         key is pressed, the green LED lights up, the buzzer beeps twice, and the system exits the setting mode. 
    (If the         key is included in the user code and the master code, the system does not exit the setting mode.) 
    - You can continue the setting up operation by entering an arbitrary setting code.
    Indicator 
    goes outBlinking
    Bleep,
    Bleep 
    						
    							9
    English
    Nederlands
    Français
    Deutsch
    Español
    ·  When the relay 1 output time is 
    set to latched output, the 
    auto-relock function is 
    disabled.
    ·  When the auto-relock function 
    is turned on, the unlock 
    function of the request to 
    exit/entry button of relay 2 is 
    disabled.·  If the 0 key illumination function 
    is turned on while the timer is 
    on, only the 0 key illumination 
    will light up, even if the "key 
    illumination time setting" is set 
    to "Indicator is continually lit".
    OFFONOFF
    ON OFFOFF ONONOperation tone OFFOperation tone ONOperation 
    tone OFFOperation 
    tone ONRelays 1 and 2 are both linkedRelays 1 and 2 
    are both linkedOnly relay 1 is linked
    Input the setting code. Input the setting code. Input the setting code.  Input the setting code. 
       Lockout
    (Default: OFF)   Auto-relock 
    (Anti-tailgate)
    (Default: OFF)   Timer-linked unlocking setting
    (Default: relay 1, OFF)
                 Operation sound settings
    (Default: ON)
    0 key illumination ONwhile timer is on0 key illumination OFFwhile timer is on0 key illumination ON
    while timer is on 0 key illumination OFF
    while timer is on
    Inputting the number of operations 
    (ex.
    9æ10 times)
    10 -99
    Inputting length of time in "Lockout" mode 
    (Ex.: 10 seconds)
    10 - 99 Input the master code twice.
    (Default :                                                                )
    Only relay 1 
    is linkedOnly relay 2 is linkedOnly relay 2 
    is linked
    Beep
    (orange)
    Illumination(green)
    Blinking
    Bleep, Bleep
    Illumination Blinking Illumination Blinking Illumination BlinkingIllumination Blinking
    Bleep Bleep BleepBleep
    Illumination Blinking Illumination Blinking Illumination Blinking
    Bleep BeepBeep
    Illumination Blinking Illumination Blinking
    Bleep
    Illumination Blinking
    BleepIllumination Blinking
    Beep
    Illumination Blinking
    Beep
    - When the         key is pressed, the green LED lights up, the buzzer beeps twice, and the system exits the setting mode. 
    (If the         key is included in the user code and the master code, the system does not exit the setting mode.) 
    - You can continue the setting up operation by entering an arbitrary setting code.
    Indicator 
    goes outBlinking
    Bleep,
    Bleep 
    						
    							10
    English
    Nederlands
    Français
    Deutsch
    Español
    OPERATIONS
    A.  Unlocking of user code
    When the registered user code has been input using the 
    keypad (between 4 and 6 digits), the LED indicator (group 
    1: orange, group 2: green) lights up, the buzzer sounds, 
    and the electric door strike is unlocked.
    Orange LED lights up (during relay1 operation)Green LED lights up (during relay2 operation)
    ex.): group 1
    1006group 2
    04B2
    BeepBeep
    •  The time interval during which the button must be 
    pressed is approximately 10 seconds. If the time 
    interval exceeds approximately 10 seconds, the input 
    value will be cleared.
    •  If you make a mistake when inputting the user code, 
    input the user code again.
    •  When the "Lockout" function has been set, the release 
    function is locked and the input operation is disabled for 
    the specified time (10 ~ 99 seconds) if invalid codes are 
    input a set number of times (10 ~ 99 times). (Reference: 
    "Lockout".) During this time, the key illumination will 
    blink 4 times, the LED (orange) indicator will blink for 
    the set deactivation time, and the buzzer will sound for 
    approximately 3 seconds. 
    B. Timer-linked unlocking
    When the timer-linked unlocking function is active, the 
    door can be unlocked by pressing the 
     key during the 
    set time, while the timer is linked.
    The 
     key illumination lights up when the timer is 
    activated by performing the setting.
    C.  Unlocking using the request to exit/entry button
    When leaving the premises, you can activate the electric 
    door strike by pressing the request to exit/entry button 
    connected to the unit. Pressing request to exit/entry 
    button 1 releases relay 1, and pressing request to exit/
    entry button 2 releases relay 2.
    •  When the door is unlocked using the request to exit/
    entry button, the LED will not light up and the buzzer 
    will not sound.
    TECHNICAL PRECAUTIONS
    •  Operating temperature: Between -10°C and 60°C
     (14˚F to 
    140˚F)
    •  Cleaning: Clean the unit with a soft cloth dampened with 
    a neutral household cleanser.  Do not use any 
    abrasive cleanser or cloths.
    •  The unit is weather resistant. However do not spray 
    high pressure water on access control keypad directly. 
    Excessive moisture may cause problems with the unit. 
    •  Press and release the 
    ,,, and  keys 
    simultaneously when this unit does not work. 
    )The LEDs (orange and green) will blink and the buzzer 
    will sound, and then resetting will take place. (The settings 
    do not return to their default values.) 
    •  If resetting does not work, contact the service technician 
    who installed the unit.
    SPECIFICATIONS
    •  Power supply:  12 ~ 24V AC
          12 ~ 24V DC
    •  Power consumption: DC: Max. 70mA
    AC: Max. 100mA
    •  Dimensions: 95.2(H) × 110(W) × 29.3(D)mm 
        H 3-2/3” x W 4-5/16” x D 1-1/8”
    •  Weight: approx. 330g (0.72lbs) 
    •  Number of relay circuits: 2
    •  Relay contact: N/O, N/C
    •  Relay contact capacity:  24V DC, 3A (resistive load)
            1A (inductive load)
            24V AC, 3A (resistive load)
            1A (inductive load)
    WARRANTY
    Aiphone warrants its products to be free from defects of material 
    and workmanship under normal use and service for a period of 
    one year after delivery to the ultimate user and will repair free 
    of charge or replace at no charge, should it become defective 
    upon which examination shall disclose to be defective and under 
    warranty. Aiphone reserves unto itself the sole right to make 
    the final decision whether there is a defect in materials and/or 
    workmanship; and whether or not the product is within the 
    warranty. This warranty shall not apply to any Aiphone product 
    which has been subject to misuse, neglect, accident, or to 
    use in violation of instructions furnished, nor extended to units 
    which have been repaired or altered outside of the factory. This 
    warranty does not cover batteries or damage caused by batteries 
    used in connection with the unit. This warranty covers bench 
    repairs only, and any repairs must be made at the shop or place 
    designated in writing by Aiphone. Aiphone will not be responsible 
    for any costs incurred involving on site service calls. Aiphone will 
    not provide compensation for any loss or damage incurred by the 
    breakdown or malfunction of its products during use, or for any 
    consequent inconvenience or losses that may result.
    FCC
    This device complies with Part 15 of the FCC Rules. 
    Operation is subject to the following two conditions: 
    (1) this device may not cause harmful interference, and 
    (2) this device must accept any interference received, 
    including interference that may cause undesired operation. 
    						