Aiphone AXWAVTR Instructions User Manual
Have a look at the manual Aiphone AXWAVTR Instructions User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 161 Aiphone manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
- INSTRUCTIONS - The AXW-AVT and AXW-AVR are designed to allow connection of a standard AX-series audio video door station (or audio-only IE-series door station) via the AXW-AVT, conditioning the signal for use with 3rdparty transmission equipment (fiber optics, Ethernet, etc.) and converting it back via the AXW-AVR to a signal compatible with the AX-series exchange unit. External video input/output is provided at both adaptors to allow 3 rdparty camera input, output to recording devices, etc. A motion detector or other activation device can be connected to the Sensor input to trigger door / camera activation (AXW-AVT only). The units also feature a relay output to trigger an external device, such as a DVR or video switcher local to either the AXW- AVT or AXW-AVR whenever the audio and/or video is active. Alternatively, the AXW-AVT can be used to adapt an AX-series audio video door station to a standalone third party device (video server, network DVR, etc). AX Series Audio-Video Adaptor for 3rdParty Transmission Equipment Pg. 1 AXW-AVT TERMINAL DEFINITIONS: DOOR (RJ-45 Jack): RJ-45 connection from AX-series audio video door, or spliced audio only door (IE/ IF-series). AUDIO IN/OUT: Input / Output connections for audio transmission (line level, polarity indicated by ‘+’ and ‘-’). CALL IN/OUT: Transistor-switched input / output to be connected to relay input / output on transmission equipment. ‘Call In’ indicates call placed by door station, ‘Call Out’ indicates master-initiated activity (polarity indicated by ‘+’ and ‘-’). SENSOR NC, NC: Normally Closed contact input, activates ‘Call In’ function when tripped by external motion detector or other device with N/C contacts. RELAY NO, NO: Normally Open relay contact, activated whenever communication is active. VIDEO IN: Composite input signal from CCTV camera, if used in place of AX-series audio video door station. VIDEO OUT: Composite output to external transmission equipment. Source dependent upon CCTV / DOOR switch. CCTV / DOOR SWITCH: Determines whether AX-series audio/video door station video (‘DOOR’ setting) or external CCTV video (‘CCTV’ setting) will be present on ‘VIDEO OUT’ for connection to external transmission equipment. 24V +, - 24V DC input (use Aiphone PS-2420UL). AXW-AVT CCTV DOOR DOOR OUT IN VIDEO AXW-AVT AUDIO + - IN OUT + -+ - 24V OUT + - CALL SENSOR NC NCRELAY NO NO + - IN 0311
AXW-AVR Pg. 2 OFF ON CEU OUT IN VIDEO AXW-AVR AUDIO + - IN OUT + - RELAY NO NOOUT + - CALL + - IN 75 OHM COMPATIBLE DOOR STATIONS (AXW-AVT): AX-DV Surface mount, die cast zinc, vandal resistant, Audio-Video AX-DVF Flush mount, stainless steel, vandal resistant, Audio-Video AX-DM Mullion mount, black plastic, Audio Only IF-DA Surface mount, brown plastic, Audio Only IE-DC Surface mount, brown plastic w/aluminum, Audio Only IE-JA Flush mount, 2 gang, stainless steel faceplate, Audio Only IE-SS Flush mount, 2-gang, stainless steel, vandal resistant, Audio Only IE-SSR Flush mount, 2-gang, stainless steel, vandal resistant w/red mushroom call button, Audio Only AXW-AVR TERMINAL DEFINITIONS: RELAY NO, NO: Normally Open relay contact, activated whenever communication is active. CALL IN/OUT: Transistor-switched input / output to be connected to relay input / output on transmission equipment. ‘Call In’ indicates call placed by door station, ‘Call Out’ indicates master-initiated activity (polarity of input / output indicated by ‘+’ and ‘-’). AUDIO IN/OUT: Input / Output connections for audio transmission (line level, polarity indicated by ‘+’ and ‘-’). VIDEO IN: Composite input signal from CCTV camera, if used in place of AX-series audio video door station. VIDEO OUT: Composite output to external transmission equipment. Source dependent upon CCTV / DOOR switch. OFF/ON SWITCH: Determines whether AX-series audio video door station video (‘DOOR’ setting) or external CCTV video (‘CCTV’ setting) will be present on ‘VIDEO OUT’ for connection to external transmission equipment. CEU (RJ-45 Jack): RJ-45 connection from AXW-AVR to CEU, simulating a standard AX-series Audio/ Video door station. PROGRAMMING: 1. Follow standard AX programming procedures as described in the AX Installation & Operation manual (included on CD with the AX CEU). 2. When configuring door stations, be sure to set the station number corresponding to the AXW-AVT / - AVR to “Video” in the AX setup utility. Typical configuration selection
CT1AT2 AT1 DT2 DT1 CR2 CR1AR2 AR1 DR2 DR1VIDSYNRX C/ETX C/LDIAGPWR VIDEO OPTICALTX RX CT2 1 3 5 1 4 1 3 5 DATA C.C. AUDIO CONFIGURATION DIAGRAM: AXW-AVT / AXW-AVR with Meridian Technology Fiber (ST/SR-AiphoneAX1-XS), 1 of 2CCTV Camera 75 Ohm, 1V Peak-to-peak (Independently powered) Normally Closed input for remote activation (i.e. motion sensor, loop detector, etc.)Normally Open contact for remote device activation (i.e. video switcher, DVR, etc.) Configuration Notes (1 of 2): 1. AX-series video door station connects to ‘DOOR’ input of AXW-AVT. Ensure that the “CCTV / DOOR’ switch on the AXW-AVT is in the ‘DOOR’ position. *2. Alternatively, an IE/IF-series or AX-DM audio door may be used, along with 3 rdparty CCTV camera. Connect audio door station to ‘Door’ input (following the wiring method shown in the AX-series installation manual, pg. 12). Connect the camera to ‘Video In’ and put the ‘CCTV / DOOR’ switch in the ‘CCTV’ position. 3. Connect the Call In / Call Out and Audio In / Audio Out connections on the AXW-AVT to the Meridian fiber transmitter module (as detailed at right, Fig. 1). For complete pin definitions, consult the Meridian installation document. Pg. 3 AXW-AVT 24V + - RELAY NO NO SENSOR NC NC CALL IN + - CALL OUT + - AUDIO IN + - AUDIO OUT + - DOOR VIDEO IN VIDEO OUT AX-DVAX-DM or IE/IF-Series Audio Door Station CAT-5eCoax * Coaxial Video Cable Optic Fiber (to SR-AiphoneAX1-XS, Pg. 5) Connection details from AXW-AVT to ST-AiphoneAX1-XS ‘Audio’ Connector Detail: Pin 1 Audio In - Pin 2 Audio In + Pin 3 Audio Out - Pin 4 Audio Out + ‘C.C.’ Connector Detail: Pin 1 Call Out - Pin 2 Call Out + Pin 3 Call In + Pin 4 Call In - ‘DATA’ Connector Detail: Pin 1 & 2 Optional Door release contact output + - PS-2420UL Pg. 4 Meridian ST-AiphoneAX1-XS Configuration Notes (1 of 2, continued): 4. When the SENSOR input is used, the door station will be turned on whenever the sensor device is activated (Normally Closed contact from 3 rdparty supplied device). 5. The RELAY output provides an optional Normally Open dry contact output which is activated whenever the AX-series door station is in use. This can be used to activate any device local to the AXW-AVT (DVR trigger, video switcher activation, local call indication, etc.). 6. Configure AXW-AVT internal jumpers as necessary (see Pg. 21). Fig. 1 Please Note: Only information pertaining to the connection and operation of the AXW-AVT / AXW-AVR and listed 3 rdparty devices interfacing with it are included here. Aiphone is not responsible for attempts to connect the AXW-AVT / AXW-AVR to untested 3 rdparty transmission hardware. Consult the installation manual for the 3 rdparty device being utilized for further information regarding physical mounting, base functionality, power requirements, etc. For the most up-to-date compatibility information, please consult http:// www.aiphone.com or contact Aiphone Technical Support. For complete AX system installation, wiring, and programming information, please consult the AX Installation Manual (included on CD with AX Central Exchange Unit, or available at http://www.aiphone.com). To Door Release
CEU AUDIO IN + - AUDIO OUT + - CALL IN + - CALL OUT + - RELAY NO NO VIDEO IN VIDEO OUT AXW-AVR To AX-CEU (Door Input) CONFIGURATION DIAGRAM: AXW-AVT / AXW-AVR with Meridian Technology Fiber (ST/SR-AiphoneAX1-XS), 2 of 2Pg. 5Pg. 6 Optic Fiber (to ST-AiphoneAX1-XS, Pg. 4) Coaxial Video Cable Normally Open contact for remote device activation (i.e. video switcher, DVR, etc.) Composite Video Output* (for CCTV monitor, DVR, etc.) Configuration Notes (2 of 2): 1. Connect the AXW-AVR ‘CEU’ connection to an unused Door station input on the AX-CEU and ensure that the AX-CEU has been programmed to accept a video door station on that input (see Pg. 2). 2. Connect the Call In / Call Out and Audio In / Audio Out connections on the AXW-AVR to the Meridian fiber receiver module (as detailed below, Fig. 2). For complete pin definitions, consult the Meridian installation document. 3. The RELAY output on the AXW-AVR provides a Normally Open dry contact output whenever the door station connection is active. This can be used to activate any device local to the AXW-AVT (DVR trigger, video switcher activation, local call indication, etc.). Application Considerations: The Meridian fiber modules shown include extra contact closures which may be used for door release output local to the door station (using dry contact output of the AX-CEU as a trigger)Power supply connections to the Meridian fiber modules are not shown, and are dictated by the mounting method chosen (standalone, rack mount, etc). Contact Meridian Technologies for available options.AXW-AVT / AXW-AVR should be mounted as close as possible to their corresponding Meridian fiber modules. Avoid mounting units near high voltage AC devices, or other sources of inductive noise. Fig. 2 Please Note: Only information pertaining to the connection and operation of the AXW-AVT / AXW-AVR and listed 3 rdparty devices interfacing with it are included here. Aiphone is not responsible for attempts to connect the AXW-AVT / AXW-AVR to untested 3 rdparty transmission hardware. Consult the installation manual for the 3 rdparty device being utilized for further information regarding physical mounting, base functionality, power requirements, etc. For the most up-to-date compatibility information, please consult http:// www.aiphone.com or contact Aiphone Technical Support. For complete AX system installation, wiring, and programming information, please consult the AX Installation Manual (included on CD with AX Central Exchange Unit, or available at http://www.aiphone.com). Meridian SR-AiphoneAX1-XSCT1AT2 AT1 DT2 DT1 CR2 CR1AR2 AR1 DR2 DR1VIDSYNRX C/ETX C/LDIAGPWR VIDEO OPTICALTX RX CT2 1 3 5 1 4 1 3 5 DATA C.C. AUDIO AXW-AVT to SR-AiphoneAX1-XS ‘Audio’ Connector Detail: Pin 1 Audio In - Pin 2 Audio In + Pin 3 Audio Out - Pin 4 Audio Out + ‘C.C.’ Connector Detail: Pin 1 Call Out - Pin 2 Call Out + Pin 3 Call In + Pin 4 Call In - ‘DATA’ Connector Detail: Pin 3 & 4 Optional Door release contact input (from CEU) From AX CEU Door Release Output
CONFIGURATION DIAGRAM: AXW-AVT / AXW-AVR with Infinova Fiber (N3732TA-M/-R, N3732RA-M/-R), 1 of 2Pg. 7Pg. 8CCTV Camera 75 Ohm, 1V Peak-to-peak (Independently powered) Normally Closed input for remote activation (i.e. motion sensor, loop detector, etc.)Normally Open contact for remote device activation (i.e. video switcher, DVR, etc.) AXW-AVT 24V + - RELAY NO NO SENSOR NC NC CALL IN + - CALL OUT + - AUDIO IN + - AUDIO OUT + - DOOR VIDEO IN VIDEO OUT AX-DVAX-DM or IE/IF-Series Audio Door Station CAT-5eCoax * + - PS-2420UL Infinova N3732TA-M Please Note: Only information pertaining to the connection and operation of the AXW-AVT / AXW-AVR and listed 3 rdparty devices interfacing with it are included here. Aiphone is not responsible for attempts to connect the AXW-AVT / AXW-AVR to untested 3 rdparty transmission hardware. Consult the installation manual for the 3 rdparty device being utilized for further information regarding physical mounting, base functionality, power requirements, etc. For the most up-to-date compatibility information, please consult http:// www.aiphone.com or contact Aiphone Technical Support. For complete AX system installation, wiring, and programming information, please consult the AX Installation Manual (included on CD with AX Central Exchange Unit, or available at http://www.aiphone.com). PWRVOP1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Optic Fiber (to N3732TA-M, Pg. 9) Configuration Notes (1 of 2): 1. AX-series video door station connects to ‘DOOR’ input of AXW-AVT. Ensure that the “CCTV / DOOR’ switch on the AXW-AVT is in the ‘DOOR’ position. *2. Alternatively, an IE/IF-series or AX-DM audio door may be used, along with 3 rdparty CCTV camera. Connect audio door station to ‘Door’ input (following the wiring method shown in the AX-series installation manual, pg. 12). Connect the camera to ‘Video In’ and put the ‘CCTV / DOOR’ switch in the ‘CCTV’ position. 3. Connect the Call In / Call Out and Audio In / Audio Out connections on the AXW-AVR to the terminal block of the Infinova N3732TA-M, as shown. For detailed terminal definitions, consult the Infinova installation document.Configuration Notes (1 of 2, continued): 4. When the SENSOR input is used, the door station will be turned on whenever the sensor device is activated (Normally Closed contact from 3 rdparty supplied device). 5. The RELAY output provides an optional Normally Open dry contact output which is activated whenever the AX-series door station is in use. This can be used to activate any device local to the AXW-AVT (DVR trigger, video switcher activation, local call indication, etc.). 6. Configure AXW-AVT internal jumpers as necessary (see Pg. 21). Coaxial Video Cable **The Infinova N3732TA provides only a single relay output, which may be used to control the door station’s standby mode (when connected to the ‘Call Out’ terminals on the AXW-AVT), or for door release. If utilized for door release, ensure that the ‘Call Out’ terminals on the AXW-AVT are shorted together. Note: This will cause the door station to be in a constant-on state, which may reduce the lifespan of the AX-series door station. ** **
CONFIGURATION DIAGRAM: AXW-AVT / AXW-AVR with Infinova Fiber (N3732TA-M/-R, N3732RA-M/-R), 2 of 2Pg. 9Pg. 10 CEU AUDIO IN + - AUDIO OUT + - CALL IN + - CALL OUT + - RELAY NO NO VIDEO IN VIDEO OUT AXW-AVR To AX-CEU (Door Input) Coaxial Video Cable Normally Open contact for remote device activation (i.e. video switcher, DVR, etc.) Composite Video Output (for CCTV monitor, DVR, etc.) Configuration Notes (2 of 2): 1. Connect the AXW-AVR ‘CEU’ connection to an unused Door station input on the AX-CEU and ensure that the AX-CEU has been programmed to accept a video door station on that input (see Pg. 2). 2. Connect the Call In / Call Out and Audio In / Audio Out connections on the AXW-AVR to the terminal block of the Infinova N3732RA-M, as shown. For detailed terminal definitions, consult the Infinova installation document. 3. Per the Infinova installation manual, set JP11 and JP21 for “600-Ohm, Balanced” audio connection. Application Consideratison: **If the Infinova fiber modules relay is to be used for door release, the ‘Call Out’ connection on the AXW-AVR will not be used. Instead, connect pins 15/16 from the fiber module to the appropriate door release output on the AX-CEU. Be sure to short together the ‘Call Out’ terminations on the AXW-AVT, as noted on Pg. 8-9.Power supply connections to the Infinova fiber modules are not shown, and are dictated by the mounting method chosen (standalone, rack mount, etc.). Contact Infinova for available options.AXW-AVT / AXW-AVR should be mounted as close as possibleto their corresponding Infinova fiber modules. Avoid mounting units near high voltage AC devices, or other sources of inductive noise. Infinova N3732RA-MPWRVOP1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Please Note: Only information pertaining to the connection and operation of the AXW-AVT / AXW-AVR and listed 3 rdparty devices interfacing with it are included here. Aiphone is not responsible for attempts to connect the AXW-AVT / AXW-AVR to untested 3 rdparty transmission hardware. Consult the installation manual for the 3 rdparty device being utilized for further information regarding physical mounting, base functionality, power requirements, etc. For the most up-to-date compatibility information, please consult http:// www.aiphone.com or contact Aiphone Technical Support. For complete AX system installation, wiring, and programming information, please consult the AX Installation Manual (included on CD with AX Central Exchange Unit, or available at http://www.aiphone.com). Optic Fiber (to N3732TA-M, Pg. 8) 4. The RELAY output on the AXW-AVR provides a Normally Open dry contact output whenever the door station connection is active. This can be used to activate any device local to the AXW-AVT (DVR trigger, video switcher activation, local call indication, etc.). **
CONFIGURATION DIAGRAM: AXW-AVT / AXW-AVR with AFI (American Fibertek) Fiber (MT/MR-89A-AX), 1 of 2Pg. 11Pg. 12CCTV Camera 75 Ohm, 1V Peak-to-peak (Independently powered) Normally Closed input for remote activation (i.e. motion sensor, loop detector, etc.)Normally Open contact for remote device activation (i.e. video switcher, DVR, etc.) AXW-AVT 24V + - RELAY NO NO SENSOR NC NC CALL IN + - CALL OUT + - AUDIO IN + - AUDIO OUT + - DOOR VIDEO IN VIDEO OUT AX-DVAX-DM or IE/IF-Series Audio Door Station CAT-5eCoax * + - PS-2420UL Please Note: Only information pertaining to the connection and operation of the AXW-AVT / AXW-AVR and listed 3 rdparty devices interfacing with it are included here. Aiphone is not responsible for attempts to connect the AXW-AVT / AXW-AVR to untested 3 rdparty transmission hardware. Consult the installation manual for the 3 rdparty device being utilized for further information regarding physical mounting, base functionality, power requirements, etc. For the most up-to-date compatibility information, please consult http:// www.aiphone.com or contact Aiphone Technical Support. For complete AX system installation, wiring, and programming information, please consult the AX Installation Manual (included on CD with AX Central Exchange Unit, or available at http://www.aiphone.com). Optic Fiber (to MR-89A-AX, Pg. 13) Configuration Notes (1 of 2): 1. AX-series video door station connects to ‘DOOR’ input of AXW-AVT. Ensure that the “CCTV / DOOR’ switch on the AXW-AVT is in the ‘DOOR’ position. *2. Alternatively, an IE/IF-series or AX-DM audio door may be used, along with 3 rdparty CCTV camera. Connect audio door station to ‘Door’ input (following the wiring method shown in the AX-series installation manual, pg. 12). Connect the camera to ‘Video In’ and put the ‘CCTV / DOOR’ switch in the ‘CCTV’ position. 3. Connect the Call In / Call Out and Audio In / Audio Out connections on the AXW-AVT to the terminal block of the AFI MT-89A-AX, as shown. For detailed terminal definitions, consult the AFI MT-89A-AX installation sheet.Configuration Notes (1 of 2, continued): 4. When the SENSOR input is used, the door station will be turned on whenever the sensor device is activated (Normally Closed contact from 3 rdparty supplied device). 5. The RELAY output provides an optional Normally Open dry contact output which is activated whenever the AX-series door station is in use. This can be used to activate any device local to the AXW-AVT (DVR trigger, video switcher activation, local call indication, etc.). 6. Configure AXW-AVT internal jumpers as necessary (see Pg. 21). Coaxial Video Cable AFI MT-89A-AXTo AFI specified/supplied power source 12VDC + - + - + - + - Door Release/ Contact Out (optional) Audio Contact ContactVideo INOptical I/O
CONFIGURATION DIAGRAM: AXW-AVT / AXW-AVR with AFI (American Fibertek) Fiber (MT/MR-89A-AX), 2 of 2Pg. 13Pg. 14 CEU AUDIO IN + - AUDIO OUT + - CALL IN + - CALL OUT + - RELAY NO NO VIDEO IN VIDEO OUT AXW-AVR To AX-CEU (Door Input) Coaxial Video Cable Normally Open contact for remote device activation (i.e. video switcher, DVR, etc.) Composite Video Output (for CCTV monitor, DVR, etc.) Configuration Notes (2 of 2): 1. Connect the Call In / Call Out and Audio In / Audio Out connections on the AXW-AVR to the terminal block of the AFI MR-89A-AX, as shown. For detailed terminal definitions, consult the AFI MR-89A-AX installation sheet. 2. Connect the AXW-AVR ‘CEU’ connection to an unused Door station input on the AX-CEU and ensure that the AX-CEU has been programmed to accept a video door station on that input (see Pg. 2). 3. The RELAY output on the AXW-AVR provides a Normally Open dry contact output whenever the door station connection is active. This can be used to activate any device local to the AXW-AVT (DVR trigger, video switcher activation, local call indication, etc.) Application Considerations: AXW-AVT / AXW-AVR should be mounted as close as possibleto their corresponding AFI fiber modules. Avoid mounting units near high voltage AC devices, or other sources of inductive noise. Please Note: Only information pertaining to the connection and operation of the AXW-AVT / AXW-AVR and listed 3 rdparty devices interfacing with it are included here. Aiphone is not responsible for attempts to connect the AXW-AVT / AXW-AVR to untested 3 rdparty transmission hardware. Consult the installation manual for the 3 rdparty device being utilized for further information regarding physical mounting, base functionality, power requirements, etc. For the most up-to-date compatibility information, please consult http:// www.aiphone.com or contact Aiphone Technical Support. For complete AX system installation, wiring, and programming information, please consult the AX Installation Manual (included on CD with AX Central Exchange Unit, or available at http://www.aiphone.com). Optic Fiber (to MT-89A-AX, Pg. 12) AFI MR-89A-AXTo AFI-specified /supplied power source 12VDC + - + - + - + -Audio Contact ContactVideo OUTOptical I/O Door Release/ Contact In (Optional)
V1 A+ A- GND A+ A- GNDAUDIO 1 AUDIO 2 C1 C2 C3 C4 CONFIGURATION DIAGRAM: AXW-AVT / AXW-AVR with KBC Networks (FPVB1-AB1-IB2-ST, FPVB1-AB1-IB2-SR), 1 of 2Pg. 15Pg. 16 Please Note: Only information pertaining to the connection and operation of the AXW-AVT / AXW-AVR and listed 3 rdparty devices interfacing with it are included here. Aiphone is not responsible for attempts to connect the AXW-AVT / AXW-AVR to untested 3 rdparty transmission hardware. Consult the installation manual for the 3 rdparty device being utilized for further information regarding physical mounting, base functionality, power requirements, etc. For the most up-to-date compatibility information, please consult http:// www.aiphone.com or contact Aiphone Technical Support. For complete AX system installation, wiring, and programming information, please consult the AX Installation Manual (included on CD with AX Central Exchange Unit, or available at http://www.aiphone.com). CCTV Camera 75 Ohm, 1V Peak-to-peak (Independently powered) Normally Closed input for remote activation (i.e. motion sensor, loop detector, etc.)Normally Open contact for remote device activation (i.e. video switcher, DVR, etc.) AX-DVAX-DM or IE/IF-Series Audio Door Station CAT-5e Coax* Coaxial Video Cable + - PS-2420UL To Door Release Configuration Notes (1 of 2): 1. AX-series video door station connects to ‘DOOR’ input of AXW-AVT. Ensure that the “CCTV / DOOR’ switch on the AXW-AVT is in the ‘DOOR’ position. *2. Alternatively, an IE/IF-series or AX-DM audio door may be used, along with 3 rdparty CCTV camera. Connect audio door station to ‘Door’ input (following the wiring method shown in the AX-series installation manual, pg. 12). Connect the camera to ‘Video In’ and put the ‘CCTV / DOOR’ switch in the ‘CCTV’ position. 3. Connect the Call In / Call Out and Audio In / Audio Out connections on the AXW-AVT to the Meridian fiber transmitter module (as detailed at right, Fig. 1). For complete pin definitions, consult the Meridian installation document.Configuration Notes (1 of 2, continued): 4. When the SENSOR input is used, the door station will be turned on whenever the sensor device is activated (Normally Closed contact from 3 rdparty supplied device). 5. The RELAY output provides an optional Normally Open dry contact output which is activated whenever the AX-series door station is in use. This can be used to activate any device local to the AXW-AVT (DVR trigger, video switcher activation, local call indication, etc.). 6. Configure AXW-AVT internal jumpers as necessary (see Pg. 21). AXW-AVT 24V + - RELAY NO NO SENSOR NC NC CALL IN + - CALL OUT + - AUDIO IN + - AUDIO OUT + - DOOR VIDEO IN VIDEO OUT KBC: FPVB1-AB1-IB2-ST
V1 A+ A- GND A+ A- GNDAUDIO 1 AUDIO 2 C1 C2 C3 C4 CONFIGURATION DIAGRAM: AXW-AVT / AXW-AVR with KBC Networks (FPVB1-AB1-IB2-ST, FPVB1-AB1-IB2-SR), 1 of 2Pg. 17Pg. 18 To AX-CEU (Door Release Output) Normally Open contact for remote device activation (i.e. video switcher, DVR, etc.) Composite Video Output (for CCTV monitor, DVR, etc.) Configuration Notes (2 of 2): 1. Connect the Call In / Call Out and Audio In / Audio Out connections on the AXW-AVR to the terminal block of the AFI MR-1890, as shown. For detailed terminal definitions, consult the AFI MR-1890 installation sheet. 2. Connect the AXW-AVR ‘CEU’ connection to an unused Door station input on the AX-CEU and ensure that the AX-CEU has been programmed to accept a video door station on that input (see Pg. 2). 3. The RELAY output on the AXW-AVR provides a Normally Open dry contact output whenever the door station connection is active. This can be used to activate any device local to the AXW- AVT (DVR trigger, video switcher activation, local call indication, etc.). Application Considerations: Power supply connections to the KBC fiber modules are not shown, and are dictated by the mounting method chosen (standalone, rack mount, etc.). Contact KBC for available options.AXW-AVT / AXW-AVR should be mounted as close as possibleto their corresponding KBC fiber modules. Avoid mounting units near high voltage AC devices, or other sources of inductive noise. Please Note: Only information pertaining to the connection and operation of the AXW-AVT / AXW-AVR and listed 3 rdparty devices interfacing with it are included here. Aiphone is not responsible for attempts to connect the AXW-AVT / AXW-AVR to untested 3 rdparty transmission hardware. Consult the installation manual for the 3 rdparty device being utilized for further information regarding physical mounting, base functionality, power requirements, etc. For the most up-to-date compatibility information, please consult http:// www.aiphone.com or contact Aiphone Technical Support. For complete AX system installation, wiring, and programming information, please consult the AX Installation Manual (included on CD with AX Central Exchange Unit, or available at http://www.aiphone.com). CEU AUDIO IN + - AUDIO OUT + - CALL IN + - CALL OUT + - RELAY NO NO VIDEO IN VIDEO OUT AXW-AVR To AX-CEU (Door Input) KBC: FPVB1-AB1-IB2-SR