Have a look at the manual Aimco Brakes Monitor ATM11 Tightening Monitor Operations Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 85 Aimco Brakes manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
30 I/O (19Pin Connector): PIN FUNCTIONWIRE COLOR ARX (RS232) Black BTX (RS232) White CGND Red DIN CYCLE (NPN OUT) Green EUNUSED Orange FBATCH RESET (OPTO IN) Blue GSUSPEND (OPTO IN) White/Black HPARAM B SELECT (OPTO IN) Red/Black JPARAM C SELECT (OPTO IN) Green/Black KPARAM D SELECT (OPTO IN) Orange/Black LCYCLE ACCEPT (RLY OUT) Blue/Black MBATCH ACCEPT (RLY OUT) Black/White NREJECT (RLY OUT) Red/White PRELAY COMMON (+24VDC OUT) Green/White ROPTO COMMON (GND) Blue/White SCYCLE ACCEPT (NPN OUT) Black/Red TBATCH ACCEPT (NPN OUT) White/Red UREJECT (NPN OUT) Orange/Red VUNUSED Blue/Red 2
I/O (19Pin Connector continued): JP3 and JP5 on this diagram can be found on the back board (CE2891) inside the AIM Tightening Monitor. Installing JP5 connects the 24VDC internal power sup ply from the relay common (PIN P). With JP5 discon nected, a user supplied voltage can be placed on PIN P and that voltage (instead of the internal 24VDC) will be returned on pins L, M and N when the relays close. Installing JP3 will make inputs FK common with the system ground. Removing JP3 lifts the ground refer ence for pins F, G, H, J, K and R. A user supplied ground reference can then be place on pin R in order to use the inputs on pins F, G, H, J, K. 3 31 31
32 DipSwitch: Inside the ATM there are two circuit boards. One of the circuit boards is attached to the front panel and the other to the back panel. Both circuit boards have eight position dipswitches on them. The dipswitch on the front board is reserved for factory use only. The dipswitch on the back board has a couple of user functions. Position 1 determines where parameters are being selected. If position 1 on the dipswitch is on, parameters are selected via the parameter switch. If position 1 is off, parameters may be selected through the 19pin connector. Position 7 on the back board controls the sonalert on the front of the unit. If this dipswitch is on, the beeper will work. If not, the beeper is silenced. 3
AIMCO CORPORATE HEADQUARTERS 10000 SE P ine Street Portland, Oregon 97216 Phone: (503) 254–66 00 Toll Free: 1-80 0-852-1368 AIMCO CHINA Room 607, No. 3998 Hongxin Rd Dibao Plaza Minhang District, Shanghai China Phone: 0086-21-34 3 19246 Fax: 0086-21-34 319245 AIMCO CORPORATION DE ME XICO SA DE CV Ave. Cristobal Colon 14529 Chihuahua, Chihuahua. 31125 Mexico Phone: (01-61 4) 380-10 10 Fax: (01-61 4) 380-10 19 AIMCO SPAIN Avenida Río Gallo, 431 19174 Galápagos - Guadalajara Spain Phone: + 34 673 34 99 25 LIT-MAN760 Rev. 03/2016 Printed in USA ©2016 AIMCO