Aimco Brakes Monitor ATM11 Tightening Monitor Operations Manual
Have a look at the manual Aimco Brakes Monitor ATM11 Tightening Monitor Operations Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 85 Aimco Brakes manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
ATM 1-1 Tightening Monitor Operation ManualPO Box 1\f4\f0, Portland OR 97\b9\b-04\f0 • 800-85\b-13\f8 • Fax 800-58\b-9015 www.aimco-global.com
TABLE OF CONTENTS Quick Start Guide ........................................................................\ ....1 Introduction ...........................................................\ ..........................3 Warnings ........................................................................\ .................4 Unit Overview ........................................................................\ ........5 Monitor Mode ........................................................................\ .........8 Programming ................................................................................10 AutoCal™ Batch Total Analog Values Programming Relays Timers Thresholds Firmware Versions Examples ...............................................................\ ........................22 Pneumatic Direct Drive Pneumatic Pulse Tools Inputs and Outputs ........................................................................\ .28 Dip-Switch ........................................................................\ ............31 2 4 5 6 \b 11 23 2\b 32
Step 1: Power up the unit and wait for the MAIN screen to appear. Once it is in view, turn the key from LOCK to PROG. Step2: The display will read PROG, MENU and then ACAL. Once the display reads ACAL, press the SET button Step 3: At this point, the display will read TOOL, OFF, PUSH, SET. Make sure the tool and transduc- er are plugged into the AIM Tightening Monitor and press SET. Step 4: After SET is pressed, the display will read RUN, TOOL, PUSH, SET. Run the tool on the target fastener allowing the clutch to turn the tool off. Once the clutch has fired, release the trig- ger on the tool and press the SET button. See page 10 for more detailed information on the AutoCal TM process. Quick Start Guide 2 A. 0 ACAL TOOL RUN WARNING: Be certain appropriate voltage is selected prior to applying power to theunit. 2
GOOD A.BAT Quick Start Guide (continued) Step 6: At the program menu, press the MODE button until the display reads X.BAT (the X will be a let- ter A-D that represents the cur- rent parameter). Press SET in order to program a new “batch” value. The key can be turned back to the locked position in order to exit the program mode without programming a new batch. 003 Step 7: The display will be showing the number of fasteners in a batch. Use the UP and DOWN buttons to set the flashing digit to the desired value. The SET key to accept the newly programmed value. TheMODE button can be used to exit this phase without pro- gramming a batch. See page 12 for more detailed information on programming the batch. Step 8: Turn the key back to the “locked” position. Step 5: If the calibration was successful, the screen will read ACAL, GOOD, PUSH, SET. Pressing SET at this point will return the ATM to the calibration menu. If calibration was unsuccessful the screen will read ACAL, BAD, PUSH, SET. Pressing SET at this point will return the ATM to the calibration menu. 3
Introduction: Thankyou for your purchase of the AIM Tightening Monitor (ATM)! We are proud to be included as part of your assembly process. This document is an operations guide for the AIM Tightening Monitor. The AIM Tightening Monitor can be outfitted to moni tor pneumatic tools. By analyzing the analog signature that these tools create, the AIM Tightening Monitor can aid in the manufac turing process by determining if a fastener has been installed properly, and also by counting the number of fasteners that have been installed. Before using the AIM Tightening Monitor, it is recommended that the user read this manual thoroughly. If this unit is mishandled a fatal accident, bodily injury, or damage to the AIM Tightening Monitor may occur. This manual is intended to be a general guide to the operations of the AIM Tightening Monitor. If any additional questions or con cerns arise, please contact an Aimco representative. Warnings: Do not disassemble the unit for repair or modifi cations. There is a high electrical voltage inside the unit that could cause electric shock. Do not allow any type of liquid to come into contact with any part of the unit. Immediately discontinue use of the unit if smoke, an abnormal odor, or an unusual sound is detected coming from the unit. 34
Warnings (continued): Insert all pneumatic fittings fully into their mat ing receptacles. Failure to do so could result in injury. Do not fold, bend or apply excessive force to any cable, hose or fitting. Cautions: Please use caution when handling this or any other electrical appliance. The AC power entry can be set to accept 110VAC or 220VAC. Before powering up the unit for the first time, be certain that the voltage selection is appropriate for the power being supplied to the unit. Avoid placing or storing this unit in a location where it may become wet or dust covered. Do not place or mount this unit in an unstable area. Dropping this unit may result in personal injury or damage to the unit. Before performing any maintenance on the unit, make sure to turn it off and remove the power plugs. There are no user serviceable parts inside the main enclo sure of the unit. I 5
Unit Overview The face of the AIM Tightening Monitor is equipped with buttons labeled DOWN, UP, SET, MODE and SUSPEND. These buttons are used during programming. The MODE button may also be pressed during operation to view different user accessible fea- tures. The SUSPEND button can be used to stop and re-start the ATM from monitoring the tool. Several LEDs (Light Emitting Diodes) also show through the face of the unit. The LEDs give unit statuses. The LEDs functions are asfollows: The RUN LED will illuminate when the tool is “in cycle”. The SETUP LED will be illuminated when the AIM Tightening Monitor is in program mode. The PSET LED will be lit when the parameter selection dip-switch is set to select parameters from the rotary knob. The ACCEPT and REJECT LEDs illuminate to indicate the status from the last fastener tightening cycle. 6
Unit Overview (continued):The SUSPEND LED will be lit any time the unit is suspended. A four character display resides in the center of the AIM Tightening Monitor’s face. This display gives feedback to the user informing the user of batch counts, totals, and also provides information dur- ing the programming phases. Also located on the front of the unit are a keyswitch and a sonalert beeper. The keyswitch can be used to place the ATM into its programming mode. The sonalert will beep each time a reject occurs. A double-beep can also be programmed to occur upon a batch accept. The left side of the unit contains a parameter selection switch, a 9 pin D- SUB connector, and a 19 pin circular I/O connector. The parameter selection switch can be rotated in order to select one of four different parameter sets. Each param- eter set can have its own Tmin, Tmax, Tclutch, threshold, and batch settings. The 9-PIN DSUB connector is used as an RS-232 port for communicating with serial devices. Pin two is the RX pin, pin three is the TX pin, and pin 5 is ground. U A. 0 \b
8 Unit Overview (continued): A 19pin circular connector is also located on the left hand side of the unit. This connector has several differ ent inputs and outputs and may be used to communicate with other devices like PLCs (Programmable Logic Controllers). The right hand side of the unit contains the power entry section and the tool port. The power entry module has a removable fuse and a means for selecting the voltage entering the box.The power entry module can be set to accept either 110VAC or 220VAC for its power. This setting is visible through a small window on the power entry module. Be certain that the appropriate voltage is selected prior to applying power to the unit! The power switch turns the unit on and off. The remote pressure transducer connector (RJ12 6 con ductor phone) is located on the right side of the box. This connector is designed to provide power to and carry an analog signal back from the remote pressure transducer. Transducer Connector Power Entry Module Power Switch
9 Monitor Mode: The ATM has two different modes of operation. These modes are the Monitor mode and the Programming mode. The Monitor mode is the state in which the AIM Tightening Monitor is set to when the keyswitch is in the locked position Monitor Mode (Individual Count): By pressing the MODE button the user can select one of several different views within the Monitor mode. Afterpower up the unit will be set to view the count of individual fasteners. Within this view, the display shows the parame ter that is in use (AD) and the number of fasteners that have been completed towards a batch. Monitor Mode (Batch): If the MODE button is pressed while viewing the Individual Count, the display will read X.BAT where X is the current parameter set (AD). Once the MODE but ton is released, the display will show the number of fasteners in the batch. The batch can be set to any number from 1 to 255 in the program mode. 8 A. 2 / 5