Aimco Brakes Monitor ATM11 Tightening Monitor Operations Manual
Here you can view all the pages of manual Aimco Brakes Monitor ATM11 Tightening Monitor Operations Manual. The Aimco Brakes manuals for Monitors are available online for free. You can easily download all the documents as PDF.
Page 21
20 Programming (Thresholds): Three thresholds exist within the ATM. These thresh- olds govern when the unit starts and stops collecting data, when the unit is in cycle, and when the unit deter- mines that the signal is “clutched out”. Threshold 1 (THR1) acts as a cycle start level for all types of ATMs. When the analog signal on either chan- nel is above THR1, the unit collects that data and stores it in memory. This data is used during the AutoCal TM process or it can also be transmitted via the...
Page 22
21 21 Programming (Thresholds continued): All three thresholds can be adjusted through the program menu. However, there is a software application avail- able that makes this process much easier and much more visual. In order to adjust a threshold’s value, turn the key- switch to PROG and press the MODE button until thedesired threshold abbreviation is in view (THR1, THR2, or THR3). While the threshold abbreviation is on the display, press the SET button. After the SET button is pressed, the value for...
Page 23
22 Programming (Firmware Versions): The final two elements in the program menu are the firmware versions. There are two microcontrollers inside the AIM Tightening Monitor (on the front board and one on the back board). Over time, new code releases may be issued to add cus tomer requested functionality or to fix an occasional bug. If new firmware is released, it is given another version number.To determine the firmware versions that are running in any given AIM Tightening Monitor, turn the key to PROG...
Page 24
23 23 Examples: The following examples were captured using the AIM Tightening Monitor and the Cyber Q software. Direct Drive Pneumatic Tool: The pneumatic signature was downloaded from a AIM Tightening Monitor that was monitoring a pneumatic direct drive tool. The analog curve has two distinct phases; the rundown phase, and the clutch out phase. If either of the phases were to be missing (or too short as determined by a timer), the fastening cycle would be considered a reject. During the rundown...
Page 25
24 Examples(Pneumatic Direct Drive continued): In order to properly qualify this process, THR1 is set around 7 psi. So, once the pressure rises above 7 psi, the ATM starts collecting data. Once the pressure drops back down below 7 psi, the ATM stops collecting data. THR2 in this example is set to 25 psi. Once the pres sure rises above 25 psi, the ATM considers the tool to be running and will either give an accept or some form of reject at the end of the cycle. THR3 is set to approximately 65 psi in...
Page 26
25 25 Example (Direct Drive Double Hit): In the example above, a direct drive pneumatic tool was used to retighten a fastener that had previously been tightened. In this curve no rundown phase exists. The clutch immediately turns the tool off and therefore TMIN is violated. A reject occurs upon the completion of a run like this one. Example (Direct Drive No Clutch): In the example above, a direct drive pneumatic tool was not allowed to tighten its fastener completely. The process was stopped prior to...
Page 27
Examples (Pneumatic Pulse Tool):The example above is a curve from a pneumatic pulse type tool. This curve has three phases. The first phase is the run down of the fastener prior to the head of the fastener seating. This initial phase occurs around 40 psi. The second phase of this fastening process is the pulsing phase. The pulsing phase occurs around 53 psi. During this phase, the tool is incrementally adjusting the fasten- er’s torque slightly upward. The final phase occurs when the clutch shuts...
Page 28
In this example, THR2 is set between the run-down phase and the pulsing phase. THR2 could be set below the run-down phase, however, a reject will be generated each time the trigger on the tool is pulled. If THR2 is set between the run down phase and the pulsing phase, the tool will have to pulse before any sta- tus (such as an accept or reject) is generated. THR3 is set between the upper peaks of the pulsing phase and the shut-off pressure. Once the pressure rises above this level, the tools is...
Page 29
Example (Pulse Tool No Clutch): In the example above a pneumatic pulse tool was not allowed to tighten its fastener completely. The process was stopped prior to the tool clutching out and therefore the pressure never rose above THR3. TCLU was violat ed and a reject occurred Example (Pulse Tool Double Hit): In the example above a pneumatic pulse tool was used to retighten a fastener that had previously been tight ened. This curve spends a very brief period between THR2 and THR3 (the rundown phase)....
Page 30
I/O (RS232): Below the parameter selection knob is a 9pin D sub miniature connector. Through the use of this connector and a NULL MODEM cable (see diagram below), a computer or another serial device can communicate with the AIM Tightening Monitor. Pin 2 on this connector is the RX or receive pin. Pin 3 is the TX or transmit pin. Pin 5 is at ground potential. The ATM communicates asynchronously through this port at 9600 baud using an 8 bit, no parity, one stop bit structure. A windows based program is...