    Have a look at the manual Aimco Brakes Cordless Tool Signature Series SPC2PGM Tool Speed Programmer User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 85 Aimco Brakes manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							1
    SPC-2PGM  
    Tool Speed Programmer 
    PO Box 16460, Portland OR 97292-0460  • 800-852-1368 • Fax 800-582-9015
    www.aimco-global.com
    INSTRUCTION MANUAL 
    						
    							3
    TABLE OF CONTENTS
    General Safety Rules  . . . . . . .3
    Functional Description . . . . . .4
    Operation Diagram  . . . . . . . .4
    Programmer Operation  . . . . .5–13
    Information Menu Page . . . . .14
    WARNING! READ ALL INSTRUCTIONS COMPLETELY BEFORE OPERATION. Comply with 
    all the instructions and rules in this manuaL . Keep these instructions in a safe place .
    SAVE THESE  INSTRUCTIONS.
    Please read this manual carefully before operation and follow the instructions  .
    1 . Avoid exposing programmer to water or humid environment .
    2 . Avoid placing programmer on unstable objects  .
    3 . Avoid pressing or impacting programmer LED display  . 
    4 .  Do not expose to direct sunlight to ensure optimum visibility of LED display  . 
    GENERAL SAFETY RULES
    Thank you for your purchase of the SPC-2PGM Programmer used in conjuncti\
    on with 
    Signature Series Precision Clutch tools from AIMCO. The Signature Series is line of 
    Cordless Tools that produce Industrial Grade accuracy when used correctly on a wid\
    e 
    range of applications. Should you have any questions regarding the Signa\
    ture Series 
    Programmer detailed in this manual or any other threaded fastening needs, please con-
    tact  your Authorized AIMCO  Representative. 
    						
    							4
    FUNCTIONAL DESCRIPTION
    Notes:
    1 . Please install a fully charged battery pack onto the tool before using the programmer to 
    make adjustments to the tool .  The tool battery is the power source for the programmer  .
    2 . Only Forward rotation (CW) rpm is adjustable . The Reverse rotation (CCW) rpm is 
    locked in at the maximum rpm capability of the tool .
    3 . Only clutch trip count (CNT) is resettable; total tool clutch trip count is not resettable  .
    4 . After changing settings with the SPC-2PGM Programmer, please remove and reinstall 
    the battery pack onto the tool .
    Setup Menu
    Information Menu
    Speed
    Buzzer Volume
    Product ID
    Total  Used Time
    Clutch Trip  CNT
    Total Tool  Clutch Trip  CNT
      Operation Diagram 
    						
    							5
    PROGRAMMER OPERATION
    Tool Speed (RPM) Setting
    Note: Tool speed is preset to maximum from the factory
    Step 1: Plug USB connector into 
    Programmer using supplied USB to 
    USB Mini cable
    Plug USB connector into Programmer as shown.
    Step 2: Plug mini USB connector into 
    the tool as shown using supplied USB 
    to USB mini cable . Press tool trigger 
    momentarily to switch Programmer on 
    and the Setup Menu, RPM EDIT screen 
    displays automatically  .
    Plug mini USB into the tool as shown. Angle Nutrunners will have connector on the tool body.
    Step 3: Current RPM setting for tool is 
    displayed .
    Step 4: Press “EDIT” to start the speed 
    adjustment .
    Press EDIT for speed adjustment. 
    						
    							6
    Step 5: Press “+” or “–” to increase or 
    decrease RPM of tool CW rotation in 
    50 RPM increments . The display shows 
    the RPM range of the tool connected 
    to the programmer (250–600 is 
    shown as an example) .
    Increase rpm.
    Decrease rpm.
    Step 6: Press “SAVE” and the value 
    will be stored into the tool that is 
    connected to the programmer  .
    Press to save value.
    Step 7: Press “EXIT” to leave the RPM 
    setting and go to Setup Menu .
    Press EXIT to return to Setup Menu.
    Step 8: When at “Setup Menu,” press 
    “>>” or “
    						
    							7
    FR Mode Setting
    For forward and reverse selection options
    Step1: Press “Enter” for mode 
    selection .
    Press ENTER for mode selection.
    Step 2: Press “” to find the 
    “FR Mode” then press “EDIT” to enable 
    changes .
    Press EDIT to get into FR Mode.
    Step 3: Press “ +” or “– “ to choose the 
    FR mode you prefer:
    (1) “0” enables the Forward (CW) 
    and Reverse (CCW) selections on 
    the tool to operate manually  . 
    (2)  “1” enables the Forward 
    (CW) operation to resume 
    automatically after the tool runs 
    in Reverse (CCW) operation once  . 
    (3)  “2” enables the tool to operate 
    in Forward (CW) operation only  .  
    Reverse (CCW) is locked out .
    Increase number.
    Decrease number.
    Step 4: Press “SAVE” and the value 
    will be stored into the tool that is 
    connected to the programmer  . The 
    set up of Forward (CW) and Reverse 
    (CCW) selection mode on the tool is 
    complete  . 
    Press SAVE to complete the setting.
    PROGRAMMER OPERATION 
    						
    							8
    Buzzer Volume Adjustment
    Step 1: Press “ENTER” for mode 
    selection .
    Press ENTER for mode selection.
    Step 2: Press “” to find the 
    Buz Volume mode and press “EDIT” to 
    enable changes .
    Press button to find Buz Volume Mode.
    Press EDIT to start setting buzzer volume.
    Step 3: Press “+” or “–” to increase or 
    decrease the tool buzzer volume  . 
    0 = Mute (no sound)
    1 = Low buzzer volume
    2 = Medium buzzer volume
    3 = Loudest buzzer volume
      Increase volume 
    Decrease  volume 
    Step 4: Press “SAVE” and the value 
    will be stored into the tool that is 
    connected to the programmer  . The 
    setting of tool buzzer volume is 
    complete  .
     
    Press “SAVE” to complet e the setting  
    PROGRAMMER OPERATION 
    						
    							9
    Start Mode Setting
    For trigger starting options
    Step 1: Press “ENTER” for mode 
    selection .
    Press ENTER for mode selection.
    Step 2: Press “” to find the 
    “Start_Mode” then press “EDIT” to 
    enable changes .
    Press EDIT to enter Start Mode.
    Step 3: Press “+ “or “– “ to select the 
    Start Mode you prefer  .
    (1) “0” Setting: 
    - First stage of trigger pull is to 
    switch on the LED light .
    - Second stage of trigger pull will 
    start full speed run down .  If the 
    clutch fails to trip (NG), the tool 
    LED will show RED .  Successful 
    clutch trip will show GREEN .  
    Increase number.
    Decrease number.
    (2) “1 – 99” Setting:
    - First stage of trigger pull is to switch on the LED light .
    - Second stage of trigger pull begins Soft Start .   The tool will run a slow RPM for 
    a chosen number of revolutions to assist in thread engagement .  The number of 
    rotations equals the number selected x 1 .25 .  
    After completion of the preset revolutions of the tool at low RPM, the tool will 
    ramp up to full RPM . If the clutch fails to trip (NG), the tool LED will show RED  .  
    Successful clutch trip will show GREEN .
    (3) “100” Setting:
    - First stage of trigger pull activates LED light and slow start RPM unlimited rotations  .
    - Second stage of trigger pull activates full speed run down . If the clutch fails to trip 
    (NG), the tool LED will show RED .  Successful clutch trip will show GREEN .
    PROGRAMMER OPERATION 
    						
    							10
    Step 4: Press “SAVE” and the value 
    will be stored into the tool that is 
    connected to the programmer .
    Press SAVE to complete the setting.