Aimco Brakes Auditor Torque Data Analyzer User Guide
Here you can view all the pages of manual Aimco Brakes Auditor Torque Data Analyzer User Guide. The Aimco Brakes manuals for Torque Measurement are available online for free. You can easily download all the documents as PDF.
Page 11
11 Reviewing Statistical Information Once rundown torque values have been stored to memory, it is possible to view statistical values based on those rundowns. To view statistical information: 1. From either MEMORY MODE or RUN MODE press the AUDIT button. A screen will display showing the following statistical values: n = number of rundowns stored into memory = the mean torque value of all stored rundowns Min = the lowest stored torque value Max = the highest stored torque...
Page 12
12 ATDA MENU FUNCTIONS The basic set-up features of the ATDA are accessed through the MENU function. Data management, system set-up, display characteristics and power management can all be configured from this area to match the users’ needs. Accessing the MENU Functions 1. Turn the ATDA On 2. The MENU structure can then be accessed in two separate ways 1) Press the Left Selection button or 2) Press the MENU button (Figure 1) Either method will result in the following screen...
Page 13
13 Setting Auto Clear 1. From the main display press MENU 2. Press the Right Selection button to select PEAK OPTIONS MENU 3. Auto Clear will be displayed 4. Use the Left Selection button to decrease the Auto Clear time from 9 seconds to OFF. Use the Right Selection button to increase the Auto Clear time from OFF to 9 seconds. Either button, when continuously pressed, will advance the value in a loop. 5. When the desired value is selected, press ENTER to save and exit. Clearing a...
Page 14
14 Setting the Filter Value 1. From the main display press MENU 2. Press the Right Selection button to select PEAK OPTIONS MENU 3. Use the SELECTION ARROW buttons to select FILTER 4. Use the Left Selection button to decrease the FILTER value. Use the Right Selection button to increase the Filter value. Either button, when continuously pressed, will advance the value in a loop. 5. When the desired value is selected, press ENTER to save and exit. Peak Blanking (1-3) PEAK BLANKING...
Page 15
15 Edit Limits (1-5) By using the EDIT LIMITS feature to set high and low limits for torque readings, the user can receive visual feedback regarding the rundown results. Setting the high and low limits appropriately will result in the following display signals: Reading outside of set limits: A red LED being lit on the ATDA keypad (Figure 1f A symbol for low readings and a symbol for high readings being displayed on the screen (Figure 1) Reading within set limits: A green...
Page 16
16 System Menu (2) Accessing the System Menu To access the SYSTEM menu: 1. From the Main Display screen, press MENU 2. Use the Selection Arrow buttons to scroll to System Menu 3. Press the Right Selection button for SELECT (SEL) 4. The user can then use the SELECTION ARROW buttons to scroll through the following options in the order shown: Sleep (2-1) To conserve battery life, the ATDA is equipped with a SLEEP mode. If a selected amount of time, from OFF to 20 minutes, has...
Page 17
17 Contrast (2-3) 1. From the main display press MENU 2. Use the Selection Arrow buttons to select SYSTEM MENU 3. Press the Right Selection button to select SYSTEM MENU 4. Use the Selection Arrow buttons to select CONTRAST 5. Use the Left and Right Selection buttons to adjust the contrast of the screen Information (2-4) Important information regarding the ATDA and the connected transducer can be viewed in the INFORMATION section of the SYSTEM MENU. This information may be valuable...
Page 18
18 Data Stream Format mmmbsdddddbuuuuucl m memory location c carriage return s sign (space or -) l line feed d data w/decimal point b blank u units Pinout Diagram Pin # Description Pin # Description 1 Unused 6 Unused 2 Transmit 7 Unused 3 Receive 8 Unused 4 Unused 9 Unused 5 Ground Print Memory (3-1) Connect the ATDA to a serial printer or computer using the appropriate cable (AIMCO part # RS232C) From the Main Display screen, press MENU Use the Selection...
Page 19
19 NOTES: ______________________________________________________________________ ______________________________________________________________________ ______________________________________________________________________ ______________________________________________________________________ ______________________________________________________________________ ______________________________________________________________________...
Page 20
Corporate Headquarters 10000 SE Pine Street Ave. Cristóbal Colon 14529 Portland, OR 97216 Chihuahua, Chihuahua. 31125 800-852-1368 Mexico FAX 800-582-9015 011-52-(614) 380-1010 www.aimco-global.com FAX 011-52-(614) 380-1019 LIT-MAN870 Rev. 03/2016 Printed in USA ©2016 AIMCO