AEM Series 2 Plug Play EMS 306611 User Manual
Have a look at the manual AEM Series 2 Plug Play EMS 306611 User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 223 AEM manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Page 11 of 13 Connection Diagram for EMS P/N 30-6611 1996-1998 Nissan 240SX S14 KA24DE (OBDII) 1997-1999 Nissan Sentra B14 SR20DE & GA16DE (Except 97 2.0L) 1997-1998 Nissan 200SX B14 SR20DE & GA16DE (Except 97 2.0L) 1996-1999 Nissan Altima U13 KA24DE (Except 96 Non CA models) Pin 1999 Infiniti G20 P10 SR20DE AEM EMS 30-6611 I/O Notes 38 Ignition Switch Main Relay Input Dedicated, +12V activates main relay circuit 39 ECCS Ground Power Ground Input Dedicated, ground for EMS 40 Camshaft Position Reference Signal Cam (T2) Signal Input Dedicated, camshaft position sensor, connected to pin 44 41 Camshaft Position Signal Crank Signal Input Dedicated, crankshaft position sensor 42 IACV-AAC Close Valve (97-99 1.6L) --- --- Not Used 43 ECCS Ground Power Ground Input Dedicated, ground for EMS 44 Camshaft Position Reference Signal Cam (T2) Signal Input Dedicated, camshaft position sensor, connected to pin 40 45 Camshaft Position Signal (97 Sentra & 200SX Only) --- --- Not Used 46 Front Heated Oxygen Sensor O2 #1 Input Dedicated, 0-5V input signal 47 Mass Air Flow Sensor MAF Input PnP for MAF sensor 48 Mass Air Flow Ground Power Ground Input Dedicated, ground for EMS 49 Sensor Power Supply +5V Sensor Output Dedicated, +5V sensor power 50 Sensor Ground Sensor Ground Output Dedicated, sensor ground 51 Engine Coolant Temperature Sensor Coolant Input Dedicated, coolant temperature sensor 52 Rear Heated Oxygen Sensor O2 #2 Input Available, O2 sensor input 53 Crankshaft Position OBD Sensor --- --- Not Used 54 Knock Sensor Knock 1 Input PnP for knock sensor 55 Rear Defogger Switch (Except 2.0L) --- --- Not Used 56 Power Supply for ECM +12V Switched Input Dedicated, +12V power for EMS 57 Ambient Temp Switch (95-96 240SX Only) Low Side 2 Output Available, switched ground, 1.5A max (connected to pin 37) 58 Data Link Connector for GST Coil 2 Output Available, switched ground, 1.5A max 59 Blower Fan Switch (99 Altima Only) --- --- Not Used 60 Headlamp Switch (except 2.0L & 95-96 240SX) Switch 3 Input Available, switched input 61 Power Supply for ECM +12V Switched Input Dedicated 62 EGR Temperature Sensor EGT 1 Input Available, jumper set to 0-5V input 63 Tank Fuel Temperature Sensor --- --- Not Used 64 Data Link Connector for CONSULT Coil 3 Output Available, switched ground 1.5A max 65 Data Link Connector for CONSULT EGT 2 Input Available, jumper set to 0-5V Input 66 Absolute Pressure MAP Input Available, manifold absolute pressure sensor 67 EVAP Pressure EGT 4 Input Available, jumper set to 0-5V input 68 Data Link Connector for CONSULT Knock 2 Input Available, 0-5V input 69 MAP/Baro Switch CAN1H Output Dedicated, CAN1 high side 70 Back-Up Power Supply Permanent +12V Input Dedicated, +12V power for EMS Wire View of AEM EMS
Page 12 of 13 Connection Diagram for EMS P/N 30-6611 1996-1998 Nissan 240SX S14 KA24DE (OBDII) 1997-1999 Nissan Sentra B14 SR20DE & GA16DE (Except 97 2.0L) 1997-1998 Nissan 200SX B14 SR20DE & GA16DE (Except 97 2.0L) 1996-1999 Nissan Altima U13 KA24DE (Except 96 Non CA models) Pin 1999 Infiniti G20 P10 SR20DE AEM EMS 30-6611 I/O Notes 101 IACV-AAC Open Valve PW1 Output PnP for idle air control 102 Injector 1 Injector 1 Output PnP for injector 1 103 EGRC-Solenoid Valve Idle 5 Output Available, switched +12V, 1.5A max 104 Injector 3 Injector 3 Output PnP for injector 3 105 EVAP Canister Purge Control Solenoid Valve Low Side 12 Output Available, switched ground, 1.5A max 106 ECCS Ground Power Ground Input Dedicated, ground for EMS 107 Injector 2 Injector 2 Output PnP for injector 2 108 EVAP Vent / Rear O2 Sensor Heater (95-96 240SX Only) Low Side 4 Output Available, switched ground, 1.5A max 109 Injector 4 Injector 4 Output PnP for injector 4 110 Rear O2 Heater (Except 95-96 240SX) Low Side 9 Output Available, switched ground, 1.5A max 111 Rear O2 Sensor Heater Ground (95-96 240SX Only) Power Ground Input Dedicated, ground for EMS 112 ECCS Ground Power Ground Input Dedicated, ground for EMS 113 Current Return Permanent +12V Input Dedicated, +12V power for EMS 114 REC Relay (240SX) / Intake VTC Solenoid (1.6L) Low Side 8 Output Available, switched ground, 1.5A max 115 Front O2 Sensor Heater Low Side 11 Output Available, switched ground, 1.5A max 116 EVAP Vent (95-96 240SX Only) Injector 9 Output Available, switched ground, 1.5A max 117 Vacuum Cut Bypass Valve (240SX Only) Injector 10 Output Available, switched ground, 1.5A max 118 ECCS Ground Power Ground Input Dedicated, ground for EMS Wire View of AEM EMS
Page 13 of 13 AEM Electronics Warranty Advanced Engine Management Inc. warrants to the consumer that all AEM Electronics products will be free from defects in material and workmanship for a period of twelve months from date of the original purchase. Products that fail within this 12-month warranty period will be repaired or replaced when determined by AEM that the product failed due to defects in material or workmanship. This warranty is limited to the repair or replacement of the AEM part. In no event shall this warranty exceed the original purchase price of the AEM part nor shall AEM be responsible for special, incidental or consequential damages or cost incurred due to the failure of this product. Warranty claims to AEM must be transportation prepaid and accompanied with dated proof of purchase. This warranty applies only to the original purchaser of product and is non-transferable. All implied warranties shall be limited in duration to the said 12-month warranty period. Improper use or installation, accident, abuse, unauthorized repairs or alterations voids this warranty. AEM disclaims any liability for consequential damages due to breach of any written or implied warranty on all products manufactured by AEM. Warranty returns will only be accepted by AEM when accompanied by a valid Return Merchandise Authorization (RMA) number. Product must be received by AEM within 30 days of the date the RMA is issued. Please note that before AEM can issue an RMA for any electronic product, it is first necessary for the installer or end user to contact the tech line at 1-800-423-0046 to discuss the problem. Most issues can be resolved over the phone. Under no circumstances should a system be returned or a RMA requested before the above process transpires. AEM will not be responsible for electronic products that are installed incorrectly, installed in a non approved application, misused, or tampered with. Any AEM electronics product can be returned for repair if it is out of the warranty period. There is a minimum charge of $75.00 for inspection and diagnosis of AEM electronic parts. Parts used in the repair of AEM electronic components will be extra. AEM will provide an estimate of repairs and receive written or electronic authorization before repairs are made to the product.