Page 11
MAINTENANCE AND CLEANING11 MAINTENANCE AND CLEANINGMAINTENANCE AND CLEANING Alarm signal reset • Turn the Lights and the Suction motor off. • Press button H and hold for at least 2 seconds, con-firmation is provided by the fact that the Led goes out. Before carrying out any maintenance or cleaning isolate the cooker hood from the mains supply. Charcoal FiltersIn the recirculation mode the charcoal filters absorb smells and unwanted odours. This filter cannot be washed or regenerated,...
Page 12
MAINTENANCE AND CLEANING12 Changing the Halogen Spot Lamp • Remove the snap-on lamp cover by levering it from under the metal ring, supporting it with one hand. • Remove the halogen lamp from the lamp holder by pulling gently. • Replace the lamp with a new one of the same type, making sure that you insert the two pins properly into the housings on the lamp holder. • Replace the snap-on lamp cover. Replacement filters and light bulbs can be obtained from...
Page 13
SOMETHING NOT WORKING - SERVICE AND SPARE PARTS13 SOMETHING NOT WORKING SERVICE AND SPARE PARTS If, having followed these instructions carefully, your cooker hood fails to work properly please carry out the following checks. Symptom The cooker hood will not start The cooker hood is not working effectively The cooker hood has switched off during operation I f after all these checks, the problem persists, contact your local Service Force Centre, quoting the model and serial number. Please note...
Page 14
GUARANTEE CONDITIONS14 GUARANTEE CONDITIONS Standard Guarantee ConditionsWe, AEG, undertake that if within 12 months of the date of the purchase this AEG built-in appliance or any part thereof is proved to be defective by reason only of faulty workmanship or materials, the company will, at our option, repair or replace the same FREE OF ANY CHARGE for labour, materials and carriage on condition that: • The appliance has been correctly installed and used only on the electrical supply stated on the...
Page 15
INSTALLATION INSTRUCTIONS - ELECTRICAL CONNECTIONS15 INSTALLATION INSTRUCTIONS It is dangerous to alter the specifications or attempt to modify this product in any way. Technical Information DIMENSIONS HEIGHT (CANOPY): 649 mm WIDTH (CANOPY): 598 - 898 mm GROSS: 33,3 kg - 37,3 kg NET: 20,1 kg - 23,7 kg ELECTRICAL SUPPLY: 220-240 V (50 Hz) POWER CONSUMPTION: 180 W FAN MOTOR:...
Page 16
INSTALLING THE COOKER HOOD16 INSTALLING THE COOKER HOOD Please ensure that when the appliance is installed it is ea-sily accessible to an engineer in the event of a breakdown. All installations must comply with the local au- thorities requirements for the discharge of exhaust air. Incorrect installation may affect the safety of this cooker hood. Installation Requirements Before installation check the wall to which the cooker hood is to be fitted for electric cables, water pipes or gas....
Page 17
INSTALLING THE COOKER HOOD17 INSTALLATION INSTRUCTIONS Wall drilling and bracket fixingAs a first step, proceed with the following drawings: • a vertical line up to the ceiling or up to the upper limit, at the centre of the area in which the hood is to be fitted; • a horizontal line at a minimum 1004 mm above the cooker top. • Mark a point (1) on the horizontal line, 247 mm to the right of the vertical reference line. • Repeat this operation on the other side, checking that the two marks are...
Page 18
INSTALLING THE COOKER HOOD18 Hood body mounting• Open the top suction panel and fasten it to the hood body on the left using the pin, so that it does not close again. • Unlock the lower suction panel by removing the fixing pin on the left, and open it. • Remove the Metal grease filters using the handles provi- ded. • Adjust the two screws Vr, in the brackets 11 a, so that they are at the start of their travel. • Hook the hood body to the two...
Page 19
INSTALLING THE COOKER HOOD19 Electrical connection and working test: • Connect the hood to the mains through a two-pole switch having a contact gap of at least 3 mm. • Remove the grease filters (see paragraph Maintenance) being sure that the connector of the feeding cable is correctly inserted in the socket placed on the side of the fan. INSTALLATION INSTRUCTIONS