ADEMCO VISTA-10P 
ADEMCO VISTA-10PSIA 
Security Systems 
   
   
User Guide 
 
 
 
 
 
 
 
 
 
 
 
 
 
K0736V3  10/04   Rev. B 

Page 2

 
– 2 – 
 
 
 
 
IMPORTANT!  
PROPER INTRUSION PROTECTION 
For proper intrusion coverage, sensors should be located at every possible point of entry to a 
home or commercial premises. This would include any skylights that may be present, and the 
upper windows in a multi-level building. 
In addition, we recommend that radio backup be used in a security system so that alarm signals 
can still be sent to the Central Monitoring Station in the event that the telephone lines are out of 
order (alarm signals...

Page 3

 
– 3 – 
 
 
Table of Contents 
 
System Overview .................................................................................................................... 5 
Introduction .......................................................................................................................... 5 
System Basics ....................................................................................................................... 5 
Using the Voice Message Center...

Page 4

 
– 4 – 
Table of Contents 
 
Panic Keys .............................................................................................................................. 24 
Using Panic Keys ................................................................................................................ 24 
Macro Key Programming & Usage ................................................................................... 25 
About Macro...

Page 5

 
– 5 – 
System Overview 
 
Introduction 
Congratulations on your ownership of a Honeywell Security System. Youve made a wise 
decision in choosing it, for it represents the latest in security protection technology today. 
This system provides: 
 •  Three forms of protection: burglary, fire* and emergency 
 •  At least one keypad which provides control of system and displays system status 
 •  Various sensors for perimeter and interior burglary protection 
 •  Smoke or combustion detectors* designed to...

Page 6

 
– 6 – 
System Overview (Continued) 
 
Zones  
 •  The system sensing devices have been assigned to various “zones,” which are 
specific areas of protection (e.g., front door, kitchen window, etc.).  
 •  Zone numbers are displayed at the keypad when an alarm or trouble condition 
occurs on a sensor. 
 
Arming, Step-Arming and Disarming Burglary Protection 
 •  The system must be armed before the burglary protection can sense intrusions. 
 •  To arm your system, enter your user code followed by the...

Page 7

 
– 7 – 
System Overview (Continued) 
  
Paging Feature 
 •  If programmed, the system can automatically send certain system condition 
messages to a pager.  
 •  The display consists of code numbers that indicate the type of condition that has 
occurred.  
 
Function Keys 
 •  The  “A”, “B”, “C”, and “D” keys on the keypad can be programmed to perform 
various functions. 
 •  Functions include: activate a Panic alarm; arm the system; provide step arming; 
switch lights on/off; send a message to a pager;...

Page 8

 
– 8 – 
About The Keypads 
 
General Information 
Your keypads allow you to control all system functions. The keypads feature the 
following: 
• A telephone style (digital) keypad 
• Liquid Crystal Display (LCD) which shows the nature and location of all 
occurrences 
• Built-in sounder which will sound during alarms and troubles. The sounder also 
beeps during certain system functions and when depressing any of the keys (to 
acknowledge the key press). 
• Backlighting of the LCD display windows....

Page 9

 
– 9 – 
About The Keypads (Continued) 
 
Fixed-Word Display Keypad 
 
 AW AY:  All burglary zones, interior and 
perimeter, are armed. 
 STAY:  Perimeter burglary zones, such as 
protected windows and doors, are 
armed. 
 INSTANT:  Entry delay is turned off:  
    Lit with STAY = Instant mode  
Lit with AWAY = Maximum mode  
ALARM
FIRE
AWAY
BYPASS
STAYCHECK    INSTANT    CANCELEDNIGHT NO AC
NOT READY
CHIME   BAT
PHONE TEST
6150disp 
FIXED-WORD DISPLAY (6150 shown) 
 
BYPASS:    This appears when one or...

Page 10

 
– 10 – 
Functions of the Keypads
 NOTE: The functions printed directly on the 
keys indicate their primary purpose; the 
functions printed under some of the keys 
(shown in brackets under the respective key), 
indicate their alternate or secondary purpose. 
 
DISPLAY WINDOW  
Alpha Display Keypads:  2-line, 32-character 
Liquid Crystal Display (LCD) keypads that display 
protection points, system status, and messages.  
Fixed-Word Display Keypads: Display 
protection zone ID and system status messages...
Start reading ADT Security Services Vista 10 Manual

Related Manuals for ADT Security Services Vista 10 Manual

All ADT Security Services manuals