Have a look at the manual ADT Security Services iCamera1000ADT Indoor LowLight Camera Installation Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 68 ADT Security Services manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

iCamera-1000-ADT Indoor Low-Light Camera Installation Guide NOTE: Please wait several minutes while the iCamera is being added to the network. 10. Once connected, click the Continue button. 11. Click Finish after installation is complete. ADT Pulse® Interactive Solutions 9

iCamera-1000-ADT Indoor Low-Light Camera Installation Guide Figure 4: Installation Using POE Cable 12. Unplug the Y -cable from the ADT Pulse Gateway , and then power off the camera. IMPORTANT IF CAMERA WILL BE INSTALLED AS A ‘WIRED’ CAMERA, USE THE LAN CABLE AND THE Y- CABLE. (REFER TO FIGURE 3 ON PAGE 5 OF THIS GUIDE.) IF CAMERA WILL BE INSTALLED AS A ‘WIRELESS’ CAMERA, USE THE POE CABLE TO SUPPLY POWER TO THE CAMERA. 10 ADT Pulse® Interactive Solutions

iCamera-1000-ADT Indoor Low-Light Camera Installation Guide Wall Mounting Instructions NOTE: Ensure that the iCamera is properly configured and added to the network before mounting the camera. * 1. Stand Placement Locate an area where you want the iCamera to be mounted. Using the wall plate as a template, make two small marks inside the moun ting holes of the wall plate. 2. Attach the Wall Plate to the Back of the Stand Place each screw in the designated slot of the wall plate until fastened. 3. Screw in 2/3 of the length of the mounting screws into the wall and drill a hole for the Ethernet cable. __________________________ * If the iCamera is to be mounted outside the range of the wireless network, consider including a WN2RP -ADT Wi -Fi Extender. ADT Pulse® Interactive Solutions 11

iCamera-1000-ADT Indoor Low-Light Camera Installation Guide iCamera Wall Mounting Instructions (continued) 4. Hook the two mounting holes on the stand into the mounting screws. 5. Attach the iCamera Stand Locate the stand mount on the back of the iCamera. Fasten the stand by turning the iCamera counterclockwise until secured. 6. Mounting the iCamera Connect the PoE cable into the LAN port of the device. 7. Connect the other end of the PoE cable to the adapter through the holes of the stand and the wall. Adjust it to the desired position and secure the iCamera firmly. 12 ADT Pulse® Interactive Solutions

iCamera-1000-ADT Indoor Low-Light Camera Installation Guide iCamera Wall Mounting Instructions (continued) 8. Connect the Power Adapter Connect the supplied power adapter to the PoE cable and power up. 9. Check the LEDs The Power LED turn s on briefly , and then starts blinking for a pproximately 15 to 20 seconds. After startup is completed, the Power LED and t he Network LED re main ON. ADT Pulse® Interactive Solutions 13

iCamera-1000-ADT Indoor Low-Light Camera Installation Guide PIR Video Motion Detection The motion event will be captured when a significant image changes within the Window of Interest. The Window of Interest is defined below. The following installation hints should be noted: 1. Take care not to install facing direct sunlight, bodies of water, or areas of moving shadows as these can lead to unintended triggers . 2. Do not position the PIR camera facing a window or direct sunlight. The device is also not suitable for using in draughty area where air conditioner or fan is installed. The excessive wind may cause false video triggering. 3. Avoid aiming directly near heat sources, such as fires, radiators, boiler, air conditioners and so on. 4. Mount the PIR camera where possible, so that the logical path of an intruder would cut across the detect ing area rather than directly towards the device. NOTE: PIR video detection is susceptible to light reflection, shade or tree/leaves movement caused by strong wind and so on. To reduce the number of unwanted video event s, please follow the camera install ation guide and make the adjustment accordingly . 14 ADT Pulse® Interactive Solutions

iCamera-1000-ADT Indoor Low-Light Camera Installation Guide Enabling Motion Detection via the ADT Security System 1. Click the Automation s tab , and then click the Add Automation button. 2. Select a trigger for this automation from the Trigger drop -down list. 3. Select Motion from the Event drop -down list. 4. Select the conditions under which you want the automation action to occur from Active drop -down list. 5. Click Add Actions . 6. From the Delay drop-down list, select the delay option you want to use for this action. 7. From the Action drop-down list, select the action you want to take place when the trigger occurs. ADT Pulse® Interactive Solutions 15

iCamera-1000-ADT Indoor Low-Light Camera Installation Guide 8. Click OK. 9. Click Save. 16 ADT Pulse® Interactive Solutions

iCamera-1000-ADT Indoor Low-Light Camera Installation Guide Appendix A: Specifications Model iCamera-1000 -ADT Dimensions , H x W x D (without stand) 2.8” x 2.8” x 0.8” ( 72mm x 72mm x 20m m) Operating Temperature Outdoors: -4°F to 113° F (-20 °C to 45 °C ) Indoor s: 32 °F to 113° F ( 0 °C to 45 °C ) Storage Temperature -4°F to 140 °F ( -20 ° C to 60 ° C ) Video Compression H.264, MPEG4 and MJPEG Network Interface 1 Ethernet 10/100BaseT (RJ45) LEDs 1 LED indicator and 12 IR LEDS Power Adapter 12VDC, 1A ADT Pulse® Interactive Solutions 17

iCamera-1000-ADT Indoor Low-Light Camera Installation Guide Appendix B: Regulatory Approvals FCC Statement This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment a nd receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. To assure continued compliance, any changes or modifications not expre ssly approved by the party responsible for compliance could void the user's authority to operate this equipment. (Example - use only shielded interface cables when connecting to computer or peripheral devices). FCC Radiation Exposure Statement This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 centimeters between the radiator and your body. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. This tra nsmitter must not be co -located or operating in conjunction with any other antenna or transmitter. CE Approvals The iCamera and the Ethernet iCamera meet the guidelines of the European Union and comply with the 99/5/EEC and RTTE 99/5EG directives, including the following standards: • EN60950 • EN300 328-2 • EN301 489-1 • EN301 489-17 This is a Class B product. In a domestic environment, this product may cause radio interference in which case the user may be required to take adequate measures. This product is UL and cUL certified and comply with UL60950 -1 Information Technology Equipment applicable requirement. 18