    Have a look at the manual ADT Security Services iCamera1000ADT Indoor LowLight Camera Installation Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 68 ADT Security Services manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							iCamera-1000-ADT Indoor Low-Light Camera Installation Guide 
     
     
    NOTE:  Please wait several minutes while the iCamera 
    is being added to 
    the network. 
     
    10.  Once connected, click the Continue  button. 
     
     
    11.  Click  Finish  after installation is complete.  
     
     
    ADT Pulse®  Interactive Solutions 9 
      
    						
    							iCamera-1000-ADT Indoor Low-Light Camera Installation Guide 
     
     
    Figure  4: Installation Using POE Cable  
     
    12.  Unplug the Y -cable from the ADT Pulse Gateway , and then power off the 
    camera.  
     
    IMPORTANT IF CAMERA WILL BE INSTALLED AS A ‘WIRED’  CAMERA, 
    USE THE LAN CABLE AND THE Y- CABLE. (REFER TO 
    FIGURE 3 ON PAGE 5 OF THIS GUIDE.)  IF CAMERA WILL 
    BE INSTALLED AS A ‘WIRELESS’ CAMERA, USE THE POE 
    CABLE TO SUPPLY POWER TO THE CAMERA.  
     
     
     
    10  ADT Pulse® Interactive Solutions 
      
    						
    							iCamera-1000-ADT Indoor Low-Light Camera Installation Guide 
      
    Wall Mounting Instructions  
     
     
    NOTE:  Ensure that the iCamera
     is properly configured and added to the 
    network before mounting the camera. *
     
     
    1. Stand Placement  
    Locate an area where you want the iCamera  to be mounted.  Using the wall 
    plate as a template, make two small marks inside the moun ting holes of the 
    wall plate.   
     
    2. Attach the Wall Plate to the Back of the Stand  
    Place each screw in the designated slot of the wall plate until fastened.  
     
    3.  Screw in 2/3 of the length of the mounting screws into the wall and drill a 
    hole for the Ethernet cable.  
     
    __________________________  
    *
    If the iCamera is to  be mounted outside the range of the wireless network, consider 
    including  a WN2RP -ADT Wi -Fi Extender.   
    ADT Pulse® Interactive Solutions 11 
      
    						
    							iCamera-1000-ADT Indoor Low-Light Camera Installation Guide 
     
    iCamera Wall Mounting Instructions (continued) 
    4. Hook the two mounting holes on the stand into the mounting screws.   
     
    5. Attach the iCamera Stand  
    Locate the stand mount on the back of the iCamera. Fasten the stand by 
    turning the iCamera counterclockwise until secured.  
    6.  Mounting the iCamera  
    Connect the PoE cable into the LAN port of the device.  
     
    7. Connect the other end of the PoE cable to the adapter through the holes of 
    the stand and the wall. Adjust it to the desired position and secure the 
    iCamera  firmly. 
     
     
     
     
     
     
     
     
     
    12  ADT Pulse® Interactive Solutions 
      
    						
    							iCamera-1000-ADT Indoor Low-Light Camera Installation Guide 
     
    iCamera Wall Mounting Instructions (continued) 
    8. Connect  the Power Adapter  
    Connect the supplied power adapter to the PoE cable and power up.  
     
    9. Check the LEDs  
    The Power  LED turn s on briefly , and then starts  blinking for a pproximately 15 
    to 20 seconds. After startup is completed, the Power  LED  and  t he  Network  
    LED  re main  ON. 
     
     
     
    ADT Pulse®  Interactive Solutions 13 
      
    						
    							iCamera-1000-ADT Indoor Low-Light Camera Installation Guide 
      
    PIR Video Motion Detection  
    The motion event will be captured when a significant image changes within the 
    Window of Interest. The Window of Interest is defined below.  
     
    The following installation hints should be noted:  
     
    1. Take care not to install facing direct sunlight, bodies of water, or areas of 
    moving shadows as these can lead to unintended triggers . 
    2.  Do not position the PIR camera facing a window or direct sunlight. The 
    device is also not suitable for using in draughty area where air conditioner or 
    fan is installed. The excessive wind may cause false video triggering.  
    3. Avoid aiming directly near heat sources, such as fires, radiators, boiler, air 
    conditioners and so on.  
    4. Mount the PIR camera where possible, so that the logical path of an intruder 
    would cut across the detect ing area rather than directly towards the device.  
     
    NOTE:  PIR video detection is susceptible to light reflection, shade or 
    tree/leaves movement caused by strong wind and so on. To 
    reduce the number of unwanted video event
    s, please follow the 
    camera install ation guide and make the adjustment accordingly .
     
     
    14  ADT Pulse® Interactive Solutions 
      
    						
    							iCamera-1000-ADT Indoor Low-Light Camera Installation Guide 
      
    Enabling Motion Detection via  the ADT Security System    
    1. Click the Automation s tab , and  then click the Add  Automation button.  
     
     
    2.  Select a trigger for this  automation from the Trigger  drop -down list.  
    3. Select  Motion  from the Event  drop -down list.  
    4. Select the conditions under which you want the automation action to occur 
    from  Active  drop -down list.  
    5. Click  Add Actions . 
     
     
    6.  From the  Delay drop-down list, select the delay option you want to use for 
    this action.  
    7. From the  Action drop-down list, select the action you want to take place 
    when the trigger occurs.  
    ADT Pulse® Interactive Solutions 15 
      
    						
    							iCamera-1000-ADT Indoor Low-Light Camera Installation Guide 
     
    8. Click  OK. 
     
     
    9.  Click  Save.  
     
     
    16  ADT Pulse® Interactive Solutions 
      
    						
    							iCamera-1000-ADT Indoor Low-Light Camera Installation Guide 
     
    Appendix A:  Specifications  
    Model iCamera-1000 -ADT  
    Dimensions , H x W x D  
    (without stand)  
    2.8” x 2.8” x 0.8” ( 72mm x 72mm x 20m m) 
    Operating   
    Temperature  
    Outdoors: -4°F to 113° F (-20 °C to 45 °C ) 
    Indoor s: 32 °F to 113° F ( 0 °C to 45 °C ) 
    Storage Temperature  -4°F to 140 °F ( -20 ° C to 60 ° C ) 
    Video Compression  H.264, MPEG4 and MJPEG  
    Network Interface 1 Ethernet 10/100BaseT (RJ45)  
    LEDs 1 LED indicator and 12  IR LEDS  
    Power Adapter  12VDC, 1A 
     
       
    ADT Pulse® Interactive Solutions 17 
      
    						
    							iCamera-1000-ADT Indoor Low-Light Camera Installation Guide 
     
    Appendix B:  Regulatory Approvals   
     
    FCC Statement   
    This equipment generates uses and can radiate radio frequency energy and, if 
    not installed and used in accordance with the instructions, may cause harmful 
    interference to radio communications. However, there is no guarantee that 
    interference will not occur in a particular installation. If this equipment does 
    cause harmful interference to radio or television  reception, which can be 
    determined by turning the equipment off and on, the user is encouraged to try to 
    correct the interference by one of the following measures:  
    •   Reorient or relocate the receiving antenna.  
    •   Increase the separation between the equipment a nd receiver. 
    •   Connect the equipment into an outlet on a circuit different from that to 
    which the receiver is connected.  
    •   Consult the dealer or an experienced radio/TV technician for help.  
    To assure continued compliance, any changes or modifications not expre ssly 
    approved by the party responsible for compliance could void the user's authority 
    to operate this equipment. (Example -  use only shielded interface cables when 
    connecting to computer or peripheral devices).  
    FCC Radiation Exposure Statement  
    This  equipment complies with FCC RF radiation exposure limits set forth for an 
    uncontrolled environment. This equipment should be installed and operated 
    with a minimum distance of 20 centimeters between the radiator and your body.  
    This device complies with Part  15 of the FCC Rules. Operation is subject to the 
    following two conditions:   
    (1) This device may not cause harmful interference, and  
    (2)  This device must accept any interference received, including interference 
    that may cause undesired operation.  
    This tra nsmitter must not be co -located or operating in conjunction with any 
    other antenna or transmitter.  
     
     
     
    CE Approvals   
    The iCamera  and the Ethernet iCamera  meet the guidelines of the European 
    Union and comply with the 99/5/EEC and RTTE 99/5EG directives, including 
    the following standards:  
    •   EN60950   
    •   EN300 328-2  
    •   EN301 489-1  
    •   EN301 489-17  
    This is a Class B product. In a domestic environment, this product may cause 
    radio interference in which case the user may be required to take adequate 
    measures.  
    This product is UL and cUL certified and comply with UL60950 -1 Information 