Have a look at the manual ADT Security Services iCamera1000ADT Indoor LowLight Camera Installation Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 68 ADT Security Services manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
ADT Pulse® Interactive Solutions iCamera -1000- ADT Indoor Low -Light Camera Installation Guide
iCamera-1000-ADT Indoor Low-Light Camera Installation Guide Table of Contents INTRODUCTION ........................................................................................................... 1 Overview ....................................................................................................................... 1 iCamera-1000 -ADT Features ............................................................................ 1 Package Contents ....................................................................................................... 2 Physical Details – iCamera-1000 -ADT.................................................................... 3 Front Panel ............................................................................................................ 3 Rear Panel .............................................................................................................. 4 INSTALLATION ............................................................................................................. 5 Configuring and Installing the iCamera-1000-ADT ............................................. 5 Adding the iCamera-1000-ADT to your ADT Pulse Wireless Network ........... 6 Wall Mounting Instructions .................................................................................... 11 PIR Video Motion Detection ................................................................................... 14 Enabling Motion Detection via the ADT Security System ....................... 15 APPENDIX A: SPECIFIC ATIONS ............................................................................ 17 APPENDIX B: REGULATORY APPROVALS .......................................................... 18 FCC Statement .......................................................................................................... 18 CE Approvals ............................................................................................................. 18 UNITED STATES LICENSE INFORMATION: AL Alabama Electronic Security Board of Licensure, 7956 Vaughn Rd., Montgomery 36116, (334) 264 -9388; AK 37950, 5520 Lake Otis Pkwy., Anchorage, AK 99507; AR E12 -041, Regulated by Arkansas Bd. of Private Investigators & Private Security Agencies, #1 State Police Plaza Dr., Little Rock, AR 72209, (501) 618 -8600; AZ ROC 279591; CA ACO7155, alarm company operators are licensed and regulated by the Bureau of Security & Investigative Services, Dept. of Consumer Affairs, Sacra mento, CA 95814, 974443, PPO17232; CT ELC.0106069 -L5; DC ECS902743; FL EF0001121; GA LVA205265, -205326, - 205572, -205679, -205878, LVU405673, -004349; HI CT -32297; ID ELE- SC-2643; IL 124001792; LA F1639, F1640, F1643, F1654, F1655; MA 172C; MI 3601206258, 5103208 - 4182 Pier North Dr. Ste. D, Flint, MI 48504; MN TS650251; NC 7535P2, 7561P2, 7562P10, 7563P7, 7565P1, 7566P9 - Alarm Systems Licensing Bd., 4901 Glenwood Ave, Ste. 200, Raleigh, 27612 (919) 788- 5320; NM 374838; NV 0077105; NJ Electrical Contrac tor Lic. #'s 34FA00140500, 34BA00179000, 7895 Browning Rd., Pennsauken, NJ 08109; NY 12000305615, Licensed by NYS Dept. of State; OH 50- 18- 0018, 50 -25 -0023, 50- 29-0003, 50- 31- 0014, 50 -48 -0008, 50 -50- 0005, 50- 76-0006, 50 -89 -0016, 53 -89 -1726; OK 1995; OR 1 96560; PA Pennsylvania Home Improvement Contractor Registration Number: PA090797; RI 35683; TN ACC- 1688, -1689, -1690, -1691, -1692, -1693, -1694, -1695, -1696; TX B17944 - 140 Heimer Rd. Ste. 100, San Antonio, TX 78232 - Texas Private Security Bureau, 58 05 N. Lamar Blvd., Austin 78752; UT 8289653; VA 11 -7345, 11 -7348, 11 -7351, 11 -7354, 11- 7598, 11-7900, 11- 8205, 11- 8353, 11-8447 2705147728 Class B Contractor Classification ESC; WA ADTLLL881DO, 11824 N Creek Pkwy #105, Bothell, WA 98011; WI 1210943; WV 049758. MS 15019511 ©2013 ADT LLC dba ADT Security Services. All rights reserved. ADT, the ADT logo, 800 ADT.ASAP and the product/service names listed in this document are marks and/or registered marks. Unauthorized use is strictly prohibited. Canada Licence number: RBQ 3019 -4070 -50. ©2013 ADT Security Services Canada, Inc. All rights reserved. ADT, the ADT logo, 800.ADT.ASAP and the product/service names listed in this document are marks and/or registered marks. Unauthorized use is strictly prohibited . Document 957YW901MY Ver sion 1.3 ii ADT Pulse® Interactive Solutions
iCamera-1000-ADT Indoor Low-Light Camera Installation Guide Introduction This installation guide provides step-by -step instructions for configuring and installing your iCamera- 1000-ADT Indoor Low -Light camera to your ADT Puls e® w ireless network. Permanent mounting instructions for the iCamera are also included. Overview The iCamera -1000- ADT (hereafter referred to as the iCamera ) monitors your home or business in a low light or dark environment. The iCamera can be used as either a wired or wireless camera using Wi -Fi connectivity that easily installs to your AD T Pulse wireless network. iCamera-1000- ADT Features • Requires only a power source and a connection to the gateway • Dust and Water Resistant • 12 infrared LEDs allow you to view images in a dark or low light setting • Can be used as a wired or wireless device • Diagonal View Angle of 60 degrees • VGA (640x480) • View images in color ADT Pulse® Interactive Solutions 1
iCamera-1000-ADT Indoor Low-Light Camera Installation Guide Package Contents 1. The iCamera -1000- ADT Indoor Low -Light Camera 2. Stand 3. Y-Cable 4. Power over Ethernet (PoE ) Cable 5. 12V Power Adapter 6. Assembly Back Plate with three screws (packaged separately) 7. Wall Mount Plate 8. Two Mounting Screws 9. Installation Guide 2 ADT Pulse® Interactive Solutions
iCamera-1000-ADT Indoor Low-Light Camera Installation Guide Physical Details – iCamera -1000- ADT Front Panel Figure 1: Front Panel 1. Light Sensor Detects lighting conditions 2. IR LEDs The LEDs help you see clearly at night or in a dark environment. 3. Day Camera Lens The Day Camera Lens is used in a bright environment. 4. Night Camera Lens The Night Camera Lens is used in a dark environment. 5. Power/Wi-Fi (green) On - Power on Off - Power off B linking - Data i s being transmitted or received Blinking Sl ow - Weak strength of Wi -Fi signal (1/2 Hz, SNR < 15 dB ) Blinking Medium - Strength of Wi -Fi signal is normal. (1/2 Hz, SNR < 15 dB) Blinking F ast - Good strength of Wi -Fi signal. (1/2 Hz, SNR < 15 dB) 6. Network LED (green) On - Power on Off - No Active connection on the LAN port, or not associated with Wireless AP ADT Pulse® Interactive Solutions 3
iCamera-1000-ADT Indoor Low-Light Camera Installation Guide Rear Panel Figure 2: Rear Panel 1. LAN Port Use in conjunction with the supplied LAN cable to connect your iCamera to the ADT Pulse Gateway. 2. Stand Mount The stand mount connects the stand to the iCamera. 3. Reset Button The reset button has two (2) functions: • Reboot. When the reset button is quickly pressed then released, the iCamera reboots. • Clear All Data. To Clear All Data and restore the factory default settings: 1. Power On. 2. Press and hold the Reset Button for eight seconds. When you release the Reset button, the iCamera is reset to the factory default settings. IMPORTANT THE RESET BUTTON WILL RESET THE iCAMERA COMMUNICATION CONFIGURATION SETTINGS AND SHOULD ONLY BE USED UNDER THE DIRECTION OF ADT SUPPORT. NOTE: The default Wireless settings are: Mode: Infrastructure SSID: ANY Wireless Security: Disabled Domain: USA Channel No.: Auto 4 ADT Pulse® Interactive Solutions
iCamera-1000-ADT Indoor Low-Light Camera Installation Guide Installation This section provides details of installing and configuring the iCamera -1000- ADT Indoor Low -Light camera . Configuring and Installing the iCamera -1000- ADT The following instructions provide details of config uring and installing the iCamera- 1000-ADT Indoor Low -Light Camera to your ADT Puls e network. Initial setup is done only one time to configure the iCamera’s wireless settings to the ADT Puls e Gateway. Figure 3: Initial Setup 1. Connect the LAN Cable to the iCamera a. Connect the LAN Cable to the LAN Port located on the back of the iCamera. b. Place the other end of the LAN Cable int o the LAN Port of the Y-Cable. 2. Connecting the Y -Cable to the Gateway c. Connect the Y -Cable (with Ethernet) in to the Device LAN port of the gateway. 3. Connecting the Power Source d. Connect the Y -Cable power adapter in to the power source. Once connected, plug the power source in to an electrical outlet. IMPORTANT DO NOT USE ANY POWER ADAPTER OTHER THAN THE ONE SPECIFIED. DOING SO MAY DAMAGE THE DEVICE. NOTE: During start up, the Power LED displays for approximately 10 to 15 seconds. When installation is complete, the Power LED a nd the Network LED remain ON. ADT Pulse® Interactive Solutions 5
iCamera-1000-ADT Indoor Low-Light Camera Installation Guide Adding the iCamera-1000- ADT to your ADT Pulse Wireless Network 1. Open your web browser. In the address bar, type: https://Portal.ADTPulse.com. 2. Type your Username and Password, and then click the Sign In button. 3. Click the System tab , and then click the Manage Devices button. 6 ADT Pulse® Interactive Solutions
iCamera-1000-ADT Indoor Low-Light Camera Installation Guide 4. In the Manage Devices Assistant , click Cameras. 5. Click the picture of the iCamera or select it from the drop- down list, and then click the Continue button. 6. Assign the iCamera a unique name (this is usually based on the location of the iCamera ) in the space provided, and then type the iCamera’s MAC ID or Server Name . ADT Pulse® Interactive Solutions 7
iCamera-1000-ADT Indoor Low-Light Camera Installation Guide 7. Click the Continue button. 8. Connect the camera to the Device Port of the gateway using the Ethernet cable (attached to the Y -Cable.) 9. Connect the supplied 12V power adapter to power up the iCamera, and then click the Continue button. 8 ADT Pulse® Interactive Solutions