    							EXUTALARMS
    ExitAlarmWarning
    DisplaysandSoundsYoursystemmaysupportandhavebeenprogrammedforthisfeature.
    Whenarming,ifanexitorinteriorzonecontainsafaultduringclosingatthetime
    theexjtcfe/ayends,thealarmsounderandconsolesoundcontinuouslytoalert
    youthatanunwantedalarmcanbepreventedifyoutakeaction:
    l
    lIfyoudisarmthesystemduringtheentrydelayperiodthatwiliimmediately
    Mow,thesoundstops.Theconsoledisplays“CANCELLEDALARM“or“CA”
    aswellasazoneindication.Nomessaaeistransmittedtothecentralstation.
    IfthesystemkNOTdisarmedduringtheimmediatelyfollowingentrydelay
    period,‘thesoundscontinueuntilthe-systemisdisarmed(oralarmsounder
    timeoutoccurs).Theconsoledisplays“EXITALARM”or“EA”aswellasazone
    indication.An“exitalarm”messaaewillbesenttothecentralstation.
    h/ote:Thelatter“EXITALARM”conditionsalsoresultifanalarmfromanexit
    orinteriorzoneoccurswithintwominutesaftertheendofanexitdelay.
    Inanyoftheabovecases,asecondOFF
    sequence(securitycode+OFFkey)
    willcleartheconsoledisplay.
    CHIMEMODE
    Yoursystemcanbesettoalertyoutotheopeningofadoororwindowwhileitis
    disarmedbyusingCHIMEmode.Whenactivated,threetoneswillsoundatthe
    Consolewheneveradoororwindowisopened.PressingtheREADYkeywill
    displaytheopenprotectionpoints.
    ToturnChimeModeon,enterthesecuritycodeandpresstheCHIMEkey.
    TheCHIMEmessagewillappear.
    ToturnChimeModeoff,enterthesecuritycodeandpresstheCHIMEkey
    again.TheCHIMEmessagewilldisappear.
    -21-
    ...
    .... 
    						
    							PANICKEYS
    Using
    PanicKeys
    (formanuallyactivating
    silentand/or
    audiblealarms)
    lIfconnectedtocentralstation.
    Yoursystemmayhavebeenprogrammedtousespecialkeysorcombinations
    ofkeystomanuallyactivateemergency(panic)functions.The
    functionsthat
    might
    beprogrammedare:SilentEmergency,AudibleEmergency,Personal
    Emergency,andFire.
    Asilentemergencysendsasilentalarmsignaltothecentralstation’,but
    thereisnoaudiblealarmorvisualdisplay.
    Anaudibleemergencysendsasignaltothecentralstation*andsoundsa
    loud,steadyalarmatyourconsole(s)andatanyexternalsoundersthatmaybe
    connected(ALARMplusazonenumberisalsodisplayed).
    Apersonalemergencyalarmsendsanemergencymessagetothecentral
    station*andsoundsatconsole(s),butnotatexternalbellsorsirens.
    Afirealarmsendsafirealarmmessagetothecentralstation*anduniquely
    soundsatconsole(s)andexternalbellsandsirens(FIREplusazonenumberis
    alsodisplayed).
    IAlsoseeDuressCodefeatureonpage10.1
    ‘b
    LETfEREDTYPICAL
    PANICd
    CONSOLEKEYPADKEYs
    (“DISNOT
    usED,b
    r-l
    -3—
    THESEKEYSNOTPRESENT
    ONALLCONSOLES_OFF
    AWAV
    STAY
    INSTANCODE
    CHIME
    READ—
    -22-
    &m
    ‘El
    q
    &.#
    PAIRED
    PANIC
    KEYS 
    						
    							PANICKEYS
    SEEYOURINSTALLER
    ANDNOTEHERE
    THEKEY(S)
    FOR&FUNCTION(S)
    PROGRAMMED
    YOURSYSTEMCHECKIF
    IPANIC
    IPROGRAMMED
    IZONE
    ACTIVEKSY(S)FUNCTIONNUMBER
    n[A]
    _SILENT,_AUDIBLE,_PERSONAL,
    —FIRE95
    n[B]
    _SILENT,_AUDIBLE,_PERSONAL,
    —FIRE07
    n[C]
    _SILENT,_AUDIBLE,_PERSONAL,
    —FIRE96
    CR
    Inl[ll&[*ll_SILENT,_AUDIBLE,_PERSONAL,
    _FIREI95I
    n[*I&[w_SILENT,_AUDIBLE,_PERSONAL,
    —FIRE07
    n[3]&[#]
    _SILENT,_AUDIBLE,_PERSONAL,
    —FIRE96
    lKEYS[A],[B],AND[C]ARENOTPRESENTONALLCONSOLES.lKEY[D],IFPRESENTONYOURCONSOLE,ISNOTACTIVEHERE,
    OUTPUTRELAYOPT!ONS
    ProgrammedAskyourinstallertoprovideinformationonanyspecialsystem
    Actionsactionsthathavebeenprogrammedduringinstallation.
    (inresponsetoACTIONSTARTEDBYSTOPPEDBY
    zoneactivitv
    ormanualentries)
    –23–
    . 
    						
    							Usingthe
    q5TESTKey
    TESTINGTHESYSTEM
    TOBECONDUCTEDWEEKLY
    TheTESTkeyputsyoursystemintoTestmode,whichallowseachprotection
    pointtobecheckedforproperoperation.
    1.
    2.
    3.
    4.
    5.
    6.Disarmthesystemandcloseallprotectedwindows,doors,etc.The
    console’sREADYmessageshouldbedisplayedandtheREADYindicator(if
    present)shouldbelit.
    EnteryoursecuritycodeandpresstheTESTkey.
    Withsomesystems,astheTestmodeisentered,theexternalsirenorbell
    willsoundforonesecondandthenturnoff.Withothersystems,thissound
    willoccur,instead,aseachzoneisfaultedinthefollowingsteps.
    Eachtimeaprotectionzoneisfaulted,theconsolesounds3beeps.
    Theconsolewillsoundasinglebeepevery40secondsasareminderthat
    thesystemisinthetestmode.
    Ifthesesoundsdonotoccur,callforserviceimmediately.
    Openandcloseeachprotecteddoorandwindowinturnandlistenforthe
    requiredsoundsTheidentificationofeachfaultedprotectionpointshould
    appearonthedisplay.
    Walkinfrontofanyinteriormotiondetectors(ifused)andlistenforthe
    requiredsoundasmovementisdetected.Theidentificationofthedetector
    shouldappearonthedisplay
    whenitisactivated.
    A/ofe:WirelessPIR(PassiveInfrared)unitswillsendsignalsoutonlyifthey
    havebeeninactivefor3minutes.
    Followthemanufacturer’sinstructionstotestallsmoke
    detectors,toensure
    thatallarefunctioningproperly.Theidentificationofeachdetectorshould
    appearonthedisplay
    wheneachisactivated.
    -24- 
    						
    							7.
    8.
    TESTINGTHESYSTEM
    Afterallprotectionpointshavebeencheckedandrestored,thereshouldbe
    nozoneidentificationnumbersdisplayed.Ifaproblemisexperienced
    withanyprotectionpoint(noconfirmingsounds,nodisplay),
    CALLFORSERVICEIMMEDIATELY.
    TurnofftheTestmodeby
    enteringthesecuritycodeandpressingtheOFF
    key.
    I
    WITHSOMESYSTEMS,
    1
    THETESTMODEWILLBEAUTOMATICALLYTERMINATEDAFTER4HOURS,
    IFTHEUSERDOESNOTMANUALLYTERMINATEITSOONER.
    ThisinsuresthattheFireandPaniczoneswillnotremaindisabled.
    d
    -25- 
    						
    							TROUBLECONDITIONS
    “Check”andThewordCHECKontheconsole’sdisplay,accompaniedbya“beeping”atthe
    “Battery”Displaysconsole,indicatesatroubleconditioninthesystem.
    Tosilencethebeepingfortheseconditions,pressanykey.
    1.Adisplayof“CHECK”andoneormorezonenumbersindicates
    thataproblemexistswiththedisplayedzone(s)andrequiresyourattention.
    IftheCHECKdisplayrelatestoafirezone,CALLFORSERVICE
    IMMEDIATELY.
    Determineifthezone(s)displayedareintactandmakethemsoiftheyare
    not.Iftheproblemhasbeencorrected,thedisplaycanbeclearedifyou
    entertheOFFsequence(usercodeplusOFFkey)twice.Ifthedisplay
    persists,CALLFORSERVICEIMMEDIATELY.
    2.Iftherearewirelesssensors*inyoursystem,
    theCHECKcondition
    mayalsobecaused
    bysomechangeintheenvironmentthatpreventsthe
    receiverfromhearingaparticular
    sensor.CALLFORSERVICE
    IMMEDIATELYifthisoccurs.
    -1-~
    ALPHA
    -~
    FIXED-WORD
    -26– 
    						
    							TROUBLECONDITIONS
    3.
    4.Adisplayof
    “BAT”withnozonenumberindicatesthatthemain
    standbybatteryinyourcontrolisweak.Ifthisconditionpersistsfor
    morethanoneday(withACpresent),CALLFORSERVICE.
    Adis~lavof“BAT”withazonenumberandaonce~erminute
    “beeping;’attheConsoleindicatesthatalowbatterycondit~onexistsin
    thewirelesssensordisplayed.Eitherreplacethebatteryyourself,or
    CALLFORSERVICE.Ifthebatteryisnotreplacedwithin
    30days,a
    CHECKdisplaymayoccur.
    Somewireless
    sensorscontainanon-replaceablelong-lifebatterywhichre-
    quiresreplacementoftheentireunitattheendofbatterylife(e.g.,5802
    Pendantand5802CPBeltClipPersonalEmergencyTransmittersand5803
    WirelessKeyTransmitters).
    PowerFailure[fthereisnoconsoledisplayatall,andthePOWERindicator(if
    present)isnotlit,
    operatingpowerforthesystemhasstoppedandthe
    systemisinoperative.CALLFORSERVICEIMMEDIATELY.
    Ifthemessage‘!ACLOSS”or“NOAC”isdisplayed,andthePOWER
    indicator(ifpresent)
    isoff,theConsoleisoperatingonbatterypoweronly.
    Ifonlysomelightsareoutonthepremises,checkcircuitbreakersandfusesand
    resetorreplaceasnecessary.CALLFORSERVICEIMMEDIATELYifAC
    powercannotberestored. 
    						
    							OtherDisplays
    Fixed-Word
    Consoles
    PartitionedSystem
    TROUBLEConditions
    dl:
    cc:
    FC:
    Oc:
    Ifthisremainsdisplayedformorethan1minute,yoursystemisdisabled.
    CALLFORSERVICEIMMEDIATELY.
    Thesystemisincommunicationwiththecentralstationforchangeof
    functionorstatusverification.Ifthismessagepersistsformorethan
    10minutes,CALLFORSERVICEIMMEDIATELY.
    Acommunicationfailurewiththecentralstationhasoccurred.
    CALLFORSERVICEIMMEDIATELY.
    The
    consoleisnotreceivinasianalsfromthecontrolpanelandseesan
    opencircuit./fthisrnessag;p%stsformorethan70minutes,CALL
    FORSERVICEIMMEDIATELY.
    IfyoursystemispartofaPartitionedSystem,itcanshareonephysicalalarm
    systembetweentwodifferentusers,eachwiththeirownrequirements(e.g.,the
    occupantsofatwofamilyhouse).
    Whenso-configured,eachpartitionoperates
    independentlyoftheother,butfromtimetotimedisplaymessagesmayappear
    temporarilyonaconsolewhichindicatetheotherpartitionisinuse(e.g.,during
    testingbyaninstaller).Donotbeconcerned,Thisisnormal.
    FORSERVICING
    INFORMATION,
    SEEPAGE43
    -28- 
    						
    							FIREALARMSYSTEM
    IFINSTALLED
    GeneralYourfirealarmsystem(ifinstalled)ison24hoursaday,forcontinuous
    protection.Intheeventofanemergency,thestrategicallylocatedsmokeand
    heatdetectorswillautomaticallysendsignalsto
    yoursystem,triggeringaloud,
    interruptedsoundfromtheConsole.Aninterruptedsoundwillalsobeproduced
    byoptionalexteriorsounders.AFIRE
    messagewillappearatyourConsoleand
    remainonuntilyousilencethealarm.
    [nCaseOf1.
    FireAlarm
    2.
    3.
    4.Shouldyoubecome
    awareofafireemergencybeforeyourdetectorssense
    theproblem,gotoyournearestConsoleandmanuallyinitiateanalarmby
    pressingthepanickeypairassignedasFIREemergency(ifprogrammedby
    theinstaller)asindicatedonpage23.
    Evacuatealloccupantsfromthepremises.
    Ifflamesand/orsmokearepresent,leavethepremisesandnotifyyourlocal
    FireDepartmentimmediately.
    Ifnoflamesorsmokeareapparent,investigatethecauseofthealarm.The
    zonenumber(s)ofthezone(s)inanalarmconditionwillbedisplayedatthe
    Console.
    TYPICALFIREEMERGENCY
    -1
    ALPHA
    –29-DISPLAYS
    FIRE
    FIXED-WORD 
    						
    							Silencing1.
    FireAlarms
    2.
    3.
    4.
    FIREALARMSYSTEM
    IFINSTALLED
    Silence
    thealarmbypressingtheOFFkey(securitycodenotneededto
    silencefirealarms).Toclearthedisplay,enteryourcodeandpresstheOFF
    keyagain(MemoryofAlarm).
    [ftheConsole’sfireindicationdoesnotclearafterthesecond
    OFF
    sequence,smokedetectorsmaystillberespondingtosmokeorheat
    producingobjectsintheirvicinity.Investigate,andshouldthisbethecase,
    eliminatethesourceofheatorsmoke.
    Ifthisdoesnotremedytheproblem,theremaystillbesmokeinthedetector.
    Clearitbyfanningthedetectorforabout30seconds.
    Whentheproblemhasbeencorrected,clearthedisplaybyenteringyour
    codeandpressingtheOFFkey.
    -30– 
    						
    All ADT Security Services manuals Comments (0)