EXUTALARMS ExitAlarmWarning DisplaysandSoundsYoursystemmaysupportandhavebeenprogrammedforthisfeature. Whenarming,ifanexitorinteriorzonecontainsafaultduringclosingatthetime theexjtcfe/ayends,thealarmsounderandconsolesoundcontinuouslytoalert youthatanunwantedalarmcanbepreventedifyoutakeaction: l lIfyoudisarmthesystemduringtheentrydelayperiodthatwiliimmediately Mow,thesoundstops.Theconsoledisplays“CANCELLEDALARM“or“CA” aswellasazoneindication.Nomessaaeistransmittedtothecentralstation. IfthesystemkNOTdisarmedduringtheimmediatelyfollowingentrydelay period,‘thesoundscontinueuntilthe-systemisdisarmed(oralarmsounder timeoutoccurs).Theconsoledisplays“EXITALARM”or“EA”aswellasazone indication.An“exitalarm”messaaewillbesenttothecentralstation. h/ote:Thelatter“EXITALARM”conditionsalsoresultifanalarmfromanexit orinteriorzoneoccurswithintwominutesaftertheendofanexitdelay. Inanyoftheabovecases,asecondOFF sequence(securitycode+OFFkey) willcleartheconsoledisplay. CHIMEMODE Yoursystemcanbesettoalertyoutotheopeningofadoororwindowwhileitis disarmedbyusingCHIMEmode.Whenactivated,threetoneswillsoundatthe Consolewheneveradoororwindowisopened.PressingtheREADYkeywill displaytheopenprotectionpoints. ToturnChimeModeon,enterthesecuritycodeandpresstheCHIMEkey. TheCHIMEmessagewillappear. ToturnChimeModeoff,enterthesecuritycodeandpresstheCHIMEkey again.TheCHIMEmessagewilldisappear. -21- ... ....
PANICKEYS Using PanicKeys (formanuallyactivating silentand/or audiblealarms) lIfconnectedtocentralstation. Yoursystemmayhavebeenprogrammedtousespecialkeysorcombinations ofkeystomanuallyactivateemergency(panic)functions.The functionsthat might beprogrammedare:SilentEmergency,AudibleEmergency,Personal Emergency,andFire. Asilentemergencysendsasilentalarmsignaltothecentralstation’,but thereisnoaudiblealarmorvisualdisplay. Anaudibleemergencysendsasignaltothecentralstation*andsoundsa loud,steadyalarmatyourconsole(s)andatanyexternalsoundersthatmaybe connected(ALARMplusazonenumberisalsodisplayed). Apersonalemergencyalarmsendsanemergencymessagetothecentral station*andsoundsatconsole(s),butnotatexternalbellsorsirens. Afirealarmsendsafirealarmmessagetothecentralstation*anduniquely soundsatconsole(s)andexternalbellsandsirens(FIREplusazonenumberis alsodisplayed). IAlsoseeDuressCodefeatureonpage10.1 ‘b LETfEREDTYPICAL PANICd CONSOLEKEYPADKEYs (“DISNOT usED,b r-l -3— THESEKEYSNOTPRESENT ONALLCONSOLES_OFF AWAV STAY INSTANCODE CHIME READ— -22- &m ‘El q &.# PAIRED PANIC KEYS
PANICKEYS SEEYOURINSTALLER ANDNOTEHERE THEKEY(S) FOR&FUNCTION(S) PROGRAMMED YOURSYSTEMCHECKIF IPANIC IPROGRAMMED IZONE ACTIVEKSY(S)FUNCTIONNUMBER n[A] _SILENT,_AUDIBLE,_PERSONAL, —FIRE95 n[B] _SILENT,_AUDIBLE,_PERSONAL, —FIRE07 n[C] _SILENT,_AUDIBLE,_PERSONAL, —FIRE96 CR Inl[ll&[*ll_SILENT,_AUDIBLE,_PERSONAL, _FIREI95I n[*I&[w_SILENT,_AUDIBLE,_PERSONAL, —FIRE07 n[3]&[#] _SILENT,_AUDIBLE,_PERSONAL, —FIRE96 lKEYS[A],[B],AND[C]ARENOTPRESENTONALLCONSOLES.lKEY[D],IFPRESENTONYOURCONSOLE,ISNOTACTIVEHERE, OUTPUTRELAYOPT!ONS ProgrammedAskyourinstallertoprovideinformationonanyspecialsystem Actionsactionsthathavebeenprogrammedduringinstallation. (inresponsetoACTIONSTARTEDBYSTOPPEDBY zoneactivitv ormanualentries) –23– .
Usingthe q5TESTKey TESTINGTHESYSTEM TOBECONDUCTEDWEEKLY TheTESTkeyputsyoursystemintoTestmode,whichallowseachprotection pointtobecheckedforproperoperation. 1. 2. 3. 4. 5. 6.Disarmthesystemandcloseallprotectedwindows,doors,etc.The console’sREADYmessageshouldbedisplayedandtheREADYindicator(if present)shouldbelit. EnteryoursecuritycodeandpresstheTESTkey. Withsomesystems,astheTestmodeisentered,theexternalsirenorbell willsoundforonesecondandthenturnoff.Withothersystems,thissound willoccur,instead,aseachzoneisfaultedinthefollowingsteps. Eachtimeaprotectionzoneisfaulted,theconsolesounds3beeps. Theconsolewillsoundasinglebeepevery40secondsasareminderthat thesystemisinthetestmode. Ifthesesoundsdonotoccur,callforserviceimmediately. Openandcloseeachprotecteddoorandwindowinturnandlistenforthe requiredsoundsTheidentificationofeachfaultedprotectionpointshould appearonthedisplay. Walkinfrontofanyinteriormotiondetectors(ifused)andlistenforthe requiredsoundasmovementisdetected.Theidentificationofthedetector shouldappearonthedisplay whenitisactivated. A/ofe:WirelessPIR(PassiveInfrared)unitswillsendsignalsoutonlyifthey havebeeninactivefor3minutes. Followthemanufacturer’sinstructionstotestallsmoke detectors,toensure thatallarefunctioningproperly.Theidentificationofeachdetectorshould appearonthedisplay wheneachisactivated. -24-
7. 8. TESTINGTHESYSTEM Afterallprotectionpointshavebeencheckedandrestored,thereshouldbe nozoneidentificationnumbersdisplayed.Ifaproblemisexperienced withanyprotectionpoint(noconfirmingsounds,nodisplay), CALLFORSERVICEIMMEDIATELY. TurnofftheTestmodeby enteringthesecuritycodeandpressingtheOFF key. I WITHSOMESYSTEMS, 1 THETESTMODEWILLBEAUTOMATICALLYTERMINATEDAFTER4HOURS, IFTHEUSERDOESNOTMANUALLYTERMINATEITSOONER. ThisinsuresthattheFireandPaniczoneswillnotremaindisabled. d -25-
TROUBLECONDITIONS “Check”andThewordCHECKontheconsole’sdisplay,accompaniedbya“beeping”atthe “Battery”Displaysconsole,indicatesatroubleconditioninthesystem. Tosilencethebeepingfortheseconditions,pressanykey. 1.Adisplayof“CHECK”andoneormorezonenumbersindicates thataproblemexistswiththedisplayedzone(s)andrequiresyourattention. IftheCHECKdisplayrelatestoafirezone,CALLFORSERVICE IMMEDIATELY. Determineifthezone(s)displayedareintactandmakethemsoiftheyare not.Iftheproblemhasbeencorrected,thedisplaycanbeclearedifyou entertheOFFsequence(usercodeplusOFFkey)twice.Ifthedisplay persists,CALLFORSERVICEIMMEDIATELY. 2.Iftherearewirelesssensors*inyoursystem, theCHECKcondition mayalsobecaused bysomechangeintheenvironmentthatpreventsthe receiverfromhearingaparticular sensor.CALLFORSERVICE IMMEDIATELYifthisoccurs. -1-~ ALPHA -~ FIXED-WORD -26–
TROUBLECONDITIONS 3. 4.Adisplayof “BAT”withnozonenumberindicatesthatthemain standbybatteryinyourcontrolisweak.Ifthisconditionpersistsfor morethanoneday(withACpresent),CALLFORSERVICE. Adis~lavof“BAT”withazonenumberandaonce~erminute “beeping;’attheConsoleindicatesthatalowbatterycondit~onexistsin thewirelesssensordisplayed.Eitherreplacethebatteryyourself,or CALLFORSERVICE.Ifthebatteryisnotreplacedwithin 30days,a CHECKdisplaymayoccur. Somewireless sensorscontainanon-replaceablelong-lifebatterywhichre- quiresreplacementoftheentireunitattheendofbatterylife(e.g.,5802 Pendantand5802CPBeltClipPersonalEmergencyTransmittersand5803 WirelessKeyTransmitters). PowerFailure[fthereisnoconsoledisplayatall,andthePOWERindicator(if present)isnotlit, operatingpowerforthesystemhasstoppedandthe systemisinoperative.CALLFORSERVICEIMMEDIATELY. Ifthemessage‘!ACLOSS”or“NOAC”isdisplayed,andthePOWER indicator(ifpresent) isoff,theConsoleisoperatingonbatterypoweronly. Ifonlysomelightsareoutonthepremises,checkcircuitbreakersandfusesand resetorreplaceasnecessary.CALLFORSERVICEIMMEDIATELYifAC powercannotberestored.
OtherDisplays Fixed-Word Consoles PartitionedSystem TROUBLEConditions dl: cc: FC: Oc: Ifthisremainsdisplayedformorethan1minute,yoursystemisdisabled. CALLFORSERVICEIMMEDIATELY. Thesystemisincommunicationwiththecentralstationforchangeof functionorstatusverification.Ifthismessagepersistsformorethan 10minutes,CALLFORSERVICEIMMEDIATELY. Acommunicationfailurewiththecentralstationhasoccurred. CALLFORSERVICEIMMEDIATELY. The consoleisnotreceivinasianalsfromthecontrolpanelandseesan opencircuit./fthisrnessag;p%stsformorethan70minutes,CALL FORSERVICEIMMEDIATELY. IfyoursystemispartofaPartitionedSystem,itcanshareonephysicalalarm systembetweentwodifferentusers,eachwiththeirownrequirements(e.g.,the occupantsofatwofamilyhouse). Whenso-configured,eachpartitionoperates independentlyoftheother,butfromtimetotimedisplaymessagesmayappear temporarilyonaconsolewhichindicatetheotherpartitionisinuse(e.g.,during testingbyaninstaller).Donotbeconcerned,Thisisnormal. FORSERVICING INFORMATION, SEEPAGE43 -28-
FIREALARMSYSTEM IFINSTALLED GeneralYourfirealarmsystem(ifinstalled)ison24hoursaday,forcontinuous protection.Intheeventofanemergency,thestrategicallylocatedsmokeand heatdetectorswillautomaticallysendsignalsto yoursystem,triggeringaloud, interruptedsoundfromtheConsole.Aninterruptedsoundwillalsobeproduced byoptionalexteriorsounders.AFIRE messagewillappearatyourConsoleand remainonuntilyousilencethealarm. [nCaseOf1. FireAlarm 2. 3. 4.Shouldyoubecome awareofafireemergencybeforeyourdetectorssense theproblem,gotoyournearestConsoleandmanuallyinitiateanalarmby pressingthepanickeypairassignedasFIREemergency(ifprogrammedby theinstaller)asindicatedonpage23. Evacuatealloccupantsfromthepremises. Ifflamesand/orsmokearepresent,leavethepremisesandnotifyyourlocal FireDepartmentimmediately. Ifnoflamesorsmokeareapparent,investigatethecauseofthealarm.The zonenumber(s)ofthezone(s)inanalarmconditionwillbedisplayedatthe Console. TYPICALFIREEMERGENCY -1 ALPHA –29-DISPLAYS FIRE FIXED-WORD
Silencing1. FireAlarms 2. 3. 4. FIREALARMSYSTEM IFINSTALLED Silence thealarmbypressingtheOFFkey(securitycodenotneededto silencefirealarms).Toclearthedisplay,enteryourcodeandpresstheOFF keyagain(MemoryofAlarm). [ftheConsole’sfireindicationdoesnotclearafterthesecond OFF sequence,smokedetectorsmaystillberespondingtosmokeorheat producingobjectsintheirvicinity.Investigate,andshouldthisbethecase, eliminatethesourceofheatorsmoke. Ifthisdoesnotremedytheproblem,theremaystillbesmokeinthedetector. Clearitbyfanningthedetectorforabout30seconds. Whentheproblemhasbeencorrected,clearthedisplaybyenteringyour codeandpressingtheOFFkey. -30–