ADS PrimeWorks User Manual November 2010 QR 775018 A0
Have a look at the manual ADS PrimeWorks User Manual November 2010 QR 775018 A0 online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 9 ADS manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
ADS PrimeWorks User Manual 55 Reset The Reset function resets the logger without affecting the database on the user’s PC. It involves discontinuing any logging activities that may be occurring with the logger, deleting all data existing in the logger memory, deleting all site details, and restarting the logger clock. This places the logger in to storage mode, in which it consumes the least amount of power . Resetting the logger essentially powers down and restarts the logger without re - establishing the previous logger configuration.
ADS PrimeWorks User Manual 56 Automatic Dialing This menu option displays the Automatic Dialing Setup dialog through which the user can configure PrimeWorks to call selected PSTN (public switched telephone network) sites automatically on a daily or weekly ba sis to readback data. Automatic Dialing Setup dialog Setup sites for automatic dial- up in the following way: 1. Select and drag the site(s) for automatic dial -up from the database navigation pane on the main screen to the Automatic Dial Sites window on the Automatic Dialing Setup dialog. 2. Choose the frequency at which to call the site(s) from one of the following options in the When to Dial section: Daily Select this radio button to dial the site( s) one time every day. Weekly Select this radio button to dial the site(s) once a week. Selecting this option enables the radio buttons representing the days of the week. Choose the radio button corresponding to the day of the week to dial the site(s) . 3. Use the Time up and down arrows in the When to Dial section to designate the time at which to call the site(s) during the selected day(s). 4. Select the Enable checkbox at the top of the dialog to ensure PrimeWorks calls the selected site(s) at the designated intervals and time following activation .
ADS PrimeWorks User Manual 57 5. Select Resume to ensure that, if the automatic dialing process is terminated prematurely during a specific interval, PrimeWorks resumes calling sites at the next scheduled interval at the same point on the Automati c Dial Sites list at which the process was previously discontinued. 6. (optional ) Select the Automatically Update Logger Time checkbox to ensure the PC automatically sets the logger clock during communication . 7. Select the OK button to activate automatic dial -up based on the selected configuration. Once activated , AutoDial displays as a new icon in the user’s W indows taskbar. Passing the cursor over the icon display s the current status of AutoDial. While AutoDial is in operation, the user cannot use PrimeWorks to call a logger manually.
ADS PrimeWorks User Manual 58 Modem Activity Log Selecting this option from the PrimeLog menu opens the Modem Activ ity L og dialog displaying all modem activity . Modem Activity Log dialog The user can clear the log by clicking on the Clear Log button.
ADS PrimeWorks User Manual 59 C H A P T E R 7 Graphing One of the primary features of PrimeWorks is producing graphs for visual analysis of logged data. This capability includes several options , such as graphing multiple sources , scaling, selecting units , and printing . This chapter describes the process for creating or generating a graph, which essentially involves the following three stages: Select ing the data Generat ing the graph Modifying the paramete rs (as required)
ADS PrimeWorks User Manual 60 Selecting the Graph Data The data navigation pane contains all the data that is available for graphing. Select the exact source data to be graphed by highlighting an item in the pane at the appropriate level. All items or data contained within (or under) that level in the data tree will be included on the graph.
ADS PrimeWorks User Manual 61 Generating the Graph Once the appropriate item or database element at the desired level has been selected, right -click and select the Graph option f rom the menu. The selected data displays in graphical format. The user can include a dditional elements in an existing graph by clicking and dragging them from the database navigation pane into the graph w indow. The graphing feature allows the user to graph either p eriodic logged data or event data. For pump event data, PrimeWorks calculates the average flow and display s it a djacent to the events. For rain gauge event data, PrimeWorks calculate s the average and total rainfalls for display adjacent to the events. Logged data displayed in a graphical format
ADS PrimeWorks User Manual 62 Modifying the Parameters for the Graph This section addresses the following topics concerning the modification of graph parameters: View ing area Legend Date/time range Current t race Query point (x and y values) Viewing A rea Moving the cursor over the scale and title areas of the graph causes the cursor to change in to a dot and arrow. Clicking when the left, right, up, or down arrow and dot are shown move s the graph area in th e direction of the cursor. The scales re -calculate and display based on the movements . C lick ing the maximiz e button on the graph window expands the graph to the maximum size and removes the window ’s borders. Legend The Legend indicates the colors representing each trace on the graph and the parameters for the trace data. When the graph includes more than 3 traces, the L egend window provides a scroll bar for scrolling through the colors and details of all the traces. The user also can use the mouse w heel to scroll through the Legend window. Legend below graph display Increase the boldness of a trace by clicking on the appropriate trace on the Legend . Right -cl icking the trace name displays the following menu: Menu displayed when right -clicking a trace entry on the Legend Select ing one of the value options from the menu displays a line on the graph corresponding to that value for the selected trace. Remove a trace from the graph by selecting the Remove option.
ADS PrimeWorks User Manual 63 Start and End Times Start and End dates/times The Start and End fields at the top left of the graph display the starting and ending dates and times representing the range of data visible on the graph. Time Scale Time Scale drop- down list The T ime Scale dr op-down list located at the top right of the graph display contains the scaling options for displaying data on the graph. T he following options are available for sele ction from the list: Time Scale options Choosing the User Defined option enables the Start and End fields for modifying the range . Start and End fields and Time Scale drop-down list Modifying the Start/End Date Modify the date in the Start or End field using the date selection dialog accessible by clicking on the down arrow in the corresponding field. The date highlighted in the calendar represents the date displayed in the Start or End field. Date selection dialog
ADS PrimeWorks User Manual 64 Select t he appropriate date from the date selection dialog. If necessary, scroll to another month and/or year using the right and left arrow buttons. Select today’s date by clicking on Today: [current date] at the bottom of the dialog . Repeat this process for th e other end of the date range as necessary. Modifying the Start/End Time Modify t he time in the Start or End field by highlight ing the hour and/or minute in the corresponding field and then entering the desired value. Repeat this process for the other end of the time range as necessary. The selected start and end time apply only to the data being plotted. Based on the sel ected values, t he time axis may autoscale to show a slightly larger timescale. Control Bar The control bar displays below the Legend at the bottom of the graph. Control bar Note: The Interval field and Save Data button are available only when graphing data derived from event data. Interval Select the interval from the drop -down list over which to average the event data. Save Data Click o n this button to save the data after changing items on the graph. Units Designate the units of measure to use for the data on the g raph from this drop- down list. Units drop- down list