Home
>
Addonics Technologies
>
Flash Duplicator
>
Addonics Technologies CFCFast Duplicator CFASTD5 user guide web
Addonics Technologies CFCFast Duplicator CFASTD5 user guide web
Have a look at the manual Addonics Technologies CFCFast Duplicator CFASTD5 user guide web online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 299 Addonics Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
www.addonics.comTechnical Support (M-F 8:30am - 6:00pm PST) Phone: 408-453-6212 Email: www.addonics.com/support/query/ Advance S etup Adv Setup offers expert users access to more advanced system settings. To access this option, hold down the ESC key for two seconds until it ap\ pears. 11 . A dv S etup R ead E rro rSki p This function sets the system to ignore any errors during the copying pr\ ocess. Normally if there is an error during copying a warning is displayed on the LCD. By using this\ function, users can also copy a HDD with errors. 11 -0 1. A dv S etu p R ea d E rro r S kip U pd ate Fir mw are This function is used to update the systems firmware. Download the late\ st version of the firmware from the Internet at www.addonics.com. For the complete instructions, vi\ sit the firmware update webpage or view the instructions found later in this manual. 11 -0 2. Adv S etu p U pd ate Fi rm ware R ea d E rro r S kip Press ENT to enter the following screen. By default this option is set t\ o OFF. Use the up and down buttons to enable or disable this option. Qu ick Erase HDD T his function is used to quickly erase all data on the HDD . Please backup an\ y important data before using this function. 1 1 -0 4.A dv S etup Q uick Era se H D D Q uick Era se H DD A LL/T a rg e t C H:* Press ENT to enter the following screen. Use the Up and Down buttons to \ select the HDD to erase. C omp are Fir mw are This function is used to compare the current system firmware version wit\ h the new version the user is upgrading to. This ensures that the downloaded firmware is the latest\ version. The message Last update F/W indicates that it is the latest version. 1 1 -0 3.A dv S etu p C om par e F ir m wareS ea rch in g F/ W . .. P le a se Wait ...L ast update F/ W O K!
www.addonics.comTechnical Support (M-F 8:30am - 6:00pm PST) Phone: 408-453-6212 Email: www.addonics.com/support/query/ All d ata w ill be l o st,E ra se? No P re ss EN T a ga in and th e L C D w ill p ro m pt yo u to confirm t he e ra se o pera tio n. F ull Er ase HDD This function is used to full erase all data on the HDD. Please backup a\ ny important data before using this function. 11 -0 5.A dv S etu p F ull E ra se H DD Q uick Era se H DD A LL /T a rg e t C H:* P re ss E N T to e nte r th e f o ll o w in g s cre en. Us e th e U p a n d D ow n b u tto ns t o s e le ct t he HD D to e ra se . A ll d ata w ill be l o st,E ra se? No P re ss EN T a ga in and th e L C D w ill p ro m pt yo u to confirm the e ra se o pera tio n. Te s t I D E 0/1 O K LCD T e st Sta rt B utto n T e st ? S D R AM Te st : 8 1 92 Kbyte s O K Fl ash Te st: OK Test Finished Once the system diagnostics have been completed the Test finished mess\ age will appear on the LCD. P re ss EN T and the system w ill b eg in t h e te st s as sh ow n be lo w . H /W D ia g no st ic Press ENT to enter the following screen. This function is used to check \ that the system is operating normally. 1 1 -0 6.A dv S etu p H /W D ia g nostic Press ENT again to enter the following screen. The LCD will cycle throug\ h the test categories as they are performed. The LCD display is tested first, the control panel i\ s tested next (requires manual operation), then followed by the systems internal diagnostics, \ hardware connection test then the RAM and SD Flash test. All test results are shown on the LCD. T\ his is a simple way to verify that the system is operating normally.
www.addonics.comTechnical Support (M-F 8:30am - 6:00pm PST) Phone: 408-453-6212 Email: www.addonics.com/support/query/ Pre ss ENT to e nte r th e f o ll o w in g scr een . Use th e U p a nd Do wn b utt o ns t o confit t o f a ct ory d efa ult s. L oad D efa u lt C onfi L oad D efa ult O k I f L o a d De fa ult O K , th is will b e d isp la yed o n th e L CD a s sh ow n b elo w . L o ad D efau lt P re ss ESC to r e tu rn to th e m ain m enu th en u se th e E N T bu tt o n to select. T his fu n ct io n re se ts allse ttin gs t o thei r f a ct ory d efa ult . T his fu n ct io n hel ps t he sy stem r e co ve r f r o m erro rs c a use d b y a nillega l o pe ra ti o n. 11 -0 7.A dv S etu p L o ad D efa ult B urn In This function is used to burn test the system reliability. 11 -0 9. A dv S etu p Bur n In P re ss E N T to e nte r th e fo ll o w in g scre en. Bur n In M ode C opy & Co mpare Use the Up and Down buttons to choose Compare, Async Copy & Cmp and Asyn\ c Compare, then press ENT to confirm. Cop y H PA If this function is set to ON, the system will completely copy the dat\ a in a source HDDs host protected area. 11 -0 8. A dv S etu p C op y H PA T he d efa ult is O FF . Use t h e E N T, U p a nd Dow n b u tto ns to ch ang e t h is to O n.
www.addonics.comTechnical Support (M-F 8:30am - 6:00pm PST) Phone: 408-453-6212 Email: www.addonics.com/support/query/ Troubleshooting LCD If the LCD display is blank after the device is turned on, check if the \ power cable is properly connected and that the power supply is on. Error Message If an operation is manually terminated by pressing ESC while the system is running a copy operation or hardware diagnostics, an error message will show up on the LCD. This may lead to an illegal operation and cause the device to stop reminding. If this happens, restart the device. Source/Target If the duplicator is unable to read the source or target please check that \ the data and power cables are properly connected. When making a copy please make sure that you set the source correctly. Keys If pressing the keys on the front panel produces no response from the sy\ stem, the keys may have malfunctioned. Startup/Shutdown Do not suddenly turn off the power while the system is performing an operation. After shutting down normally, wait a moment (usually around 2 seconds) before restarting the system so it can run self-diagnostics.
www.addonics.comTechnical Support (M-F 8:30am - 6:00pm PST) Phone: 408-453-6212 Email: www.addonics.com/support/query/ LCD Messages Connecting with a HDD: All data will be lost, format? All data will be lost. Confirm formatting. Delete Image in Partition xx? Confirm the deleting of data image in partition xx. Format? Ask if you want to format. Format OK! The formatting has been completed. HDD not Format! The hard disk hasn’t been formatted yet. HDD too small The capacity of hard disk is too small. HDD too small to handle image! The hard disk hasn’t enough capacity to store the data image (at least 5Gbytes). Image Exists Overwrite? There is a data image in the current partition. Confirm the overwriting of data. Image load Fail The image isn’t successfully loaded from DVD to the hard disk. Image load OK The image is successfully loaded from DVD to the hard disk No Image in Partition xx There is no data image in partition xx. No Valid HDD! The system cannot find a hard disk. Partition Damage The partition is damaged. Select HD First! Select a formatted hard disk at first. Verify Disk or Partition? Do you want to verify the hard disk or just a partition? Verify Hard Disk Fail! The hard disk is not verified successfully. Firmware Update: Check Sum Error! The updated firmware has errors. Flash ROM fail! Data cannot be written into Flash ROM. Invalid firmware The disc doesn’t contain a valid firmware. Last update F/W Fail! The firmware is not updated successfully. Last update F/W OK! The firmware is updated successfully. Searching F/W The system is searching for a valid firmware. Source can’t be Hard Disk! During comparison the source cannot be hard disk.
www.addonics.com Phone: 408-573-8580 Fax: 408-573-8588 Email: http://www.addonics.com/sales/query/ CONTACT US