Page 11
10 VSCD3 cable to primary video output port [ALIF2000 when using one very high resolution DVI-D dual link display] Use a DVI-D Dual Link cable (such as Adder part: VSCD3) to connect the primary video port of the computer system to the DVI-D-1 connector of the ALIF2000. A dual link cable must also be used at the RX unit. TX video link ALIF units support DVI digital video signals and so use DVI-D video connectors throughout. •...
Page 12
11 TX audio links The ALIF units support two way stereo digital sound so that you can use a remote microphone as well as speakers. To make audio links 1 Connect an audio link cable between the LINE OUT socket on the TX unit rear panel and the speaker output socket of the host computer. LINE IN LINE OUT COMPUTER 2 [Where a microphone is to be used]: Connect a second audio link cable between the LINE IN socket on the TX unit rear...
Page 13
12 TX USB link ALIF units act as USB 2.0 hubs and so can provide four sockets at the RX unit with only a single connection at the TX unit. To make a USB link 1 Connect the type B connector of the supplied USB cable to the USB port on the TX unit rear panel. OPTIO NS 1 2 1 2 2 Connect the type A connector of the cable to a vacant USB socket on the host computer. TX AUX port The AUX port is an RS232 serial port that allows extension...
Page 14
13 TX power in Each ALIF unit is supplied with an appropriate power adapter. When all other connections have been made, connect and switch on the power adapter unit. Note: Please see Power adapter identification shown opposite. To apply power in 1 Attach the output lead from the power adapter to the 5V socket on the rear panel of the unit. INDOOR USE ONL Y OPT 1 5V2.5A 1 2 Connect the IEC connector of the supplied country-specific...
Page 15
14 [ALIF2000] When making Gigabit Ethernet links TX/RX network link ALIF units can be either connected directly to each other or via a Gigabit Ethernet network. Additionally, ALIF2000 units can be networked by fibre optic links. For direct links over Ethernet cable, the length of cable should not exceed 100 metres (328 feet). Network cables used for connections may be category 5, 5e, 6 or 7 twisted-pair cable. ALIF TX units have an...
Page 16
15 RX video display ALIF units support DVI digital video signals and so use DVI-D video connectors throughout. • ALIF1000 models can support a single high resolution DVI-D video display at pixel clocks up to 165MHz (equating to an example display mode of 1920 x 1200 at 60Hz refresh). • ALIF2000 models can simultaneously support up to two high resolution video displays at pixel clocks up to 165MHz; or can alternatively support one...
Page 17
16 AUX 1 RX microphone & speakers The ALIF unit can support a microphone as well as speakers providing the necessary connections have been made between the ALIF TX unit and the host computer. To connect a microphone (or line in) and/or speakers 1 Connect the lead from a mono microphone or, alternatively, a line in connection from an audio device to the 3.5mm socket labelled LINE IN/MIC IN on the rear panel. 2 Connect the lead from...
Page 18
17 RX USB devices The ALIF RX unit has four USB ports to which peripherals may be connected. The ports are interchangeable. To connect more than four peripherals, one or more USB hubs may be used. The total current that may be drawn from the USB ports is 1.2A, which should be sufficient for a keyboard, mouse (no more than 100mA each) and any two other devices (500mA maximum each). If more power for USB devices is required, use a...
Page 19
18 RX power in Each ALIF unit is supplied with an appropriate power adapter. When all other connections have been made, connect and switch on the power adapter unit. Note: Please see Power adapter identification shown opposite. To apply power in 1 Attach the output lead from the power adapter to the 5V socket on the rear panel of the unit. 2 Connect the IEC connector of the supplied country-specific power lead to the socket of the...
Page 20
19 Configuration Initial configuration ALIF units are designed to be as flexible as possible and this princip\ le extends also to their configuration. Direct linking Where an ALIF TX and an ALIF RX are directly linked to each other, no configuration action is required, provided that they have their factor\ y default settings in place. If the standard settings have been changed in a previ\ ous installation, you merely need to perform a...