ADDERLink INFINITY dual Manual v30
Have a look at the manual ADDERLink INFINITY dual Manual v30 online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 78 ADDER manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
40 INSTALLATION CONFIGURATION OPERATION FURTHERINFORMATION INDEX Configuring the switches and devices The layout is vital but so too is the configuration: • Enable IGMP Snooping on all L2 switches. • Ensure that IGMP Fast-Leave is enabled on all switches with ALIF units connected directly to them. • Enable the L3 switch as an IGMP Querier. • Enable Spanning Tree Protocol (STP) on all switches and importantly also enable portfast (only) on all switch ports that have ALIF units connected. • If any hosts will use any video resolutions using 2048 horizontal pixels (e.g. 2048 x 1152), ensure that Jumbo Frames are enabled on all switches. • Choose an appropriate forwarding mode on all switches. Use Cut-through if available, otherwise Store and forward. • Optimize the settings on the ALIF transmitters: • If moving video images are being shown frequently, then leave Frame Skipping at a low percentage and instead reduce the Peak bandwidth limiter. • Where screens are quite static, try increasing the Background Refresh interval and/ or increasing the Frame skipping percentage setting. Make changes to the ALIF transmitters one at a time, in small steps, and view typical video images so that you can attribute positive or negative results to the appropriate control. • Ensure that all ALIF units are fully updated to the latest firmware version (at least v2.1).
41 INSTALLATION CONFIGURATION OPERATION FURTHERINFORMATION INDEX APPENDIX D - Troubleshooting Problem: The video image of the ALIF receiver shows horizontal lines across the screen. This issue is known as Blinding because the resulting video image looks as though you’re viewing it through a venetian blind. When video is transmitted by ALIF units, the various lines of each screen are divided up and transmitted as separate data packets. If the reception of those packets is disturbed, then blinding is caused. The lines are displayed in place of the missing video data packets. There are several possible causes for the loss of data packets: • Incorrect switch configuration. The problem could be caused by multicast flooding, which causes unnecessary network traffic. This is what IGMP snooping is designed to combat, however, there can be numerous causes of the flooding. • Speed/memory bandwidth issues within one or more switches. The speed and capabilities of different switch models varies greatly. If a switch cannot maintain pace with the quantity of data being sent through it, then it will inevitably start dropping packets. • One or more ALIF units may be outputting Jumbo frames due to the video resolution (2048 horizontal pixels) being used. If jumbo frames are output by an ALIF unit, but the network switches have not been configured to use jumbo frames, the switches will attempt to break the large packets down into standard packets. This process introduces a certain latency and could be a cause for dropped packets. • One or more ALIF units may be using an old firmware version. Firmware versions prior to v2.1 exhibited an issue with the timing of IGMP join and lea ve commands that caused multicast flooding in certain configurations. Remedies: • Ensure that IGMP snooping is enabled on all switches within the subnet. • Where each ALIF unit is connected as the sole device on a port connection to a switch, enable IGMP Fast-Leave (aka Immediate Leave) to reduce unnecessary processing on each switch. • Check the video resolution(s) being fed into the ALIF transmitters. If resolutions using 2048 horizontal pixels are unavoidable then ensure that Jumbo frames are enabled on all switches. • Check the forwarding mode on the switches. If Store and forward is being used, try selecting Cut-through as this mode causes reduced latency on lesser switch designs. • Ensure that one device within the subnet is correctly configured as an IGMP Querier, usually a layer 3 switch or multicast router. • Ensure that the firmware in every ALIF unit is version 2.1 or greater. • Try adjusting the transmitter settings on each ALIF to make the output data stream as efficient as possible. See ALIF transmitter video settings for details. continued
42 INSTALLATION CONFIGURATION OPERATION FURTHERINFORMATION INDEX Problem: The mouse pointer of the ALIF receiver is slow or sluggish when moved across the screen. This issue is often related to either using dithering on the video output of one or more transmitting computers or using VGA-to-DVI video converters. Dithering is used to improve the perceived quality and color depth of images by diffusing or altering the color of pixels between video frames. This practice is commonly used on Apple Mac computers using ATI or Nvidia graphics cards. VGA-to-DVI converters unwittingly produce a similar issue by creating high levels of pixel background noise. ALIF units attempt to considerably reduce network traffic by transmitting only the pixels that change between successive video frames. When dithering is enabled and/or VGA-to- DVI converters are used, this can have the effect of changing almost every pixel between each frame, thus forcing the ALIF transmitter to send the whole of every frame: resulting in greatly increased network traffic and what’s perceived as sluggish performance. Remedies: • Linux PCs Check the video settings on the PC. If the Dither video box option is enabled, disable it. • Apple Mac with Nvidia graphics Use the Adder utility for Mac’s – Contact technical support. • Apple Mac with ATI graphics Enable the Magic Eye dither removal feature. • Windows PCs If you suspect these issues with PC’s, contact technical support for assistance. • Replace old VGA adapters on host computers with DVI video cards. Problem: My monitor is displaying a pink screen It is possible that the source computer and ALIF transmitter are sending a high resolution Dual Link signal in response to a request from your Dual Link monitor. However, your ALIF receiver is unable to correctly process the signal, causing the pink screen issue (DVI resolutions above 1920 x 1200 are generally Dual Link). ALIF2002T and 2112T transmitters are able to send Dual Link video when requested, however, an ALIF2000R receiver is required to process the higher resolution signal fully at the other end. Other receivers, such as the ALIF1000R, 1002R and 2020R units cannot process Dual Link DVI as they are Single Link devices. Ensure that the ALIF transmitter is set to supply a Single Link EDID to the graphics card. When the video source is changed to a Single Link video resolution, the pink screen should disappear and the video should be displayed normally. Alternatively, change the monitor to a Single Link DVI monitor. It is important not to mix Dual Link Transmitters with Single Link Receivers. On an A.I.M. controlled system, ensure that the Video compatibility check is enabled as this ensures that the correct video mode is displayed for the monitor being used. Problem: The audio output of the ALIF receiver sounds like a scratched re- cord. This issue is called Audio crackle and is a symptom of the same problem that produces blinding (see previous page). The issue is related to missing data packets. Remedies: As per blinding discussed previously. Problem: A.I.M. cannot locate working ALIF units. There are a few possible causes: • The ALIF units must be reset back to their zero config IP addresses for A.I.M. discovery. If you have a working network of ALIF’s without A.I.M. and then add A.I.M. to the network A.I.M. will not discover the ALIFs until they are reset to the zero config IP addresses. • This could be caused by Layer 2 Cisco switches that have Spanning Tree Protocol (STP) enabled but do not also have portfast enabled on the ports to which ALIF units are connected. Without portfast enabled, ALIF units will all be assigned the same zero config IP address at reboot and A.I.M. will only acquire them one at a time on a random basis. You can easily tell whether portfast is enabled on a switch that is running STP: When you plug the link cable from a working ALIF unit into the switch port, check how long it takes for the port indicator to change from orange to green. If it takes roughly one second, portfast is on; if it takes roughly thirty seconds then portfast is disabled. Remedies: • Ensure that the ALIF units and the A.I.M. server are located within the same subnet because A.I.M. cannot cross subnet boundaries. • Manually reset the ALIF units to their zero config IP addresses. • Enable portfast on all switch ports that have ALIF units attached to them or try temporarily disabling STP on the switches while A.I.M. is attempting to locate ALIF units.
43 INSTALLATION CONFIGURATION OPERATION FURTHERINFORMATION INDEX APPENDIX E - Glossary Internet Group Management Protocol Where an ALIF transmitter is required to stream video to two or more receivers, multicasting is the method used. Multicasting involves the delivery of identical data to multiple receivers simultaneously without the need to maintain individual links. When multicast data packets enter a subnet, the natural reaction of the switches that bind all the hosts together within the subnet, is to spread the multicast data to all of their ports. This is referred to as Multicast flooding and means that the hosts (or at least their network interfaces) are required to process plenty of data that they didn’t request. IGMP offers a partial solution. The Internet Group Management Protocol (IGMP) is designed to prevent multicast flooding by allowing Layer 3 switches to check whether host computers within their care are interested in receiving particular multicast transmissions. They can then direct multicast data only to those points that require it and can shut off a multicast stream if the subnet has no recipients. There are currently three IGMP versions: 1, 2 and 3, with each version building upon the capabilities of the previous one: • IGMPv1 allows host computers to opt into a multicast transmission using a Join Group message, it is then incumbent on the router to discover when they no longer wish to receive; this is achieved by polling them (see IGMP Querier below) until they no longer respond. • IGMPv2 includes the means for hosts to opt out as well as in, using a Leave Group message. • IGMPv3 encompasses the abilities of versions 1 and 2 but also adds the ability for hosts to specify particular sources of multicast data. AdderLink Infinity units make use of IGMPv2 when performing multicasts to ensure that no unnecessary congestion is caused. IGMP Snooping The IGMP messages are effective but only operate at layer 2 - intended for routers to determine whether multicast data should enter a subnet. A relatively recent development has taken place within the switches that glue together all of the hosts within each subnet: IGMP Snooping. IGMP snooping means these layer 2 devices now have the ability to take a peek at the IGMP messages. As a result, the switches can then determine exactly which of their own hosts have requested to receive a multicast – and only pass on multicast data to those hosts. IGMP Querier When IGMP is used, each subnet requires one Layer 3 switch to act as a Querier. In this lead role, the switch periodically sends out IGMP Query messages and in response all hosts report which multicast streams they wish to receive. The Querier device and all snooping Layer 2 switches, then update their lists accordingly (the lists are also updated when Join Group and Leave Group (IGMPv2) messages are received). IGMP Fast-Leave (aka Immediate Leave) When a device/host no longer wishes to receive a multicast transmission, it can issue an IGMP Leave Group message as mentioned above. This causes the switch to issue an IGMP Group-Specific Query message on the port (that the Leave Group was received on) to check no other receivers exist on that connection that wish to remain a part of the multicast. This process has a cost in terms of switch processor activity and time. Where ALIF units are connected directly to the switch (with no other devices on the same port) then enabling IGMP Fast-Leave mode means that switches can immediately remove receivers without going through a full checking procedure. Where multiple units are regularly joining and leaving multicasts, this can speed up performance considerably. Jumbo frames (Jumbo packets) Since its commercial introduction in 1980, the Ethernet standard has been successfully extended and adapted to keep pace with the ever improving capabilities of computer systems. The achievable data rates, for instance, have risen in ten-fold leaps from the original 10Mbit/s to a current maximum of 100Gbit/s. While data speeds have increased massively, the standard defining the number of bytes (known as the Payload) placed into each data packet has remained resolutely stuck at its original level of 1500 bytes. This standard was set during the original speed era (10Mbits/s) and offered the best compromise at that speed between the time taken to process each packet and the time required to resend faulty packets due to transmission errors. But now networks are much faster and files/data streams are much larger; so time for a change? Unfortunately, a wholesale change to the packet size is not straightforward as it is a fundamental standard and changing it would mean a loss of backward compatibility with older systems. Larger payload options have been around for a while, however, they have often been vendor specific and at present they remain outside the official standard. There is, however, increased consensus on an optional ‘Jumbo’ payload size of 9000 bytes and this is fully supported by the AdderLink Infinity (ALIF) units. Jumbo frames (or Jumbo packets) offer advantages for ALIF units when transmitting certain high resolution video signals across a network. This is because the increased data in each packet reduces the number of packets that need to be transferred and dealt with - thus reducing latency times. The main problem is that for jumbo frames to be possible on a network, all of the devices on the network must support them.
44 INSTALLATION CONFIGURATION OPERATION FURTHERINFORMATION INDEX Spanning Tree Protocol (STP) In order to build a robust network, it is necessary to include certain levels of redundancy within the interconnections between switches. This will help to ensure that a failure of one link does not lead to a complete failure of the whole network. The danger of multiple links is that data packets, especially multicast packets, become involved in continual loops as neighbouring switches use the duplicated links to send and resend them to each other. To prevent such bridging loops from occurring, the Spanning Tree Protocol (STP), operating at layer 2, is used within each switch. STP encourages all switches to communicate and learn about each other. It prevents bridging loops by blocking newly discovered links until it can discover the nature of the link: is it a new host or a new switch? The problem with this is that the discovery process can take up to 50 seconds before the block is lifted, causing problematic timeouts. The answer to this issue is to enable the portfast variable for all host links on a switch. This will cause any new connection to go immediately into forwarding mode. However, take particular care not to enable portfast on any switch to switch connections as this will result in bridging loops. Forwarding modes In essence, the job of a layer 2 switch is to transfer as fast as possible, data packets arriving at one port out to another port as determined by the destination address. This is known as data forwarding and most switches offer a choice of methods to achieve this. Choosing the most appropriate forwarding method can often have a sizeable impact on the overall speed of switching: • Store and forward is the original method and requires the switch to save each entire data packet to buffer memory, run an error check and then forward if no error is found (or otherwise discard it). • Cut-through was developed to address the latency issues suffered by some store and forward switches. The switch begins interpreting each data packet as it arrives. Once the initial addressing information has been read, the switch immediately begins forwarding the data packet while the remainder is still arriving. Once all of the packet has been received, an error check is performed and, if necessary, the packet is tagged as being in error. This checking ‘on-the-fly’ means that cut-through switches cannot discard faulty packets themselves. However, on receipt of the marked packet, a host will carry out the discard process. • Fragment-free is a hybrid of the above two methods. It waits until the first 64 bits have been received before beginning to forward each data packet. This way the switch is more likely to locate and discard faulty packets that are fragmented due to collisions with other data packets. • Adaptive switches automatically choose between the above methods. Usually they start out as a cut-through switches and change to store and forward or fragment- free methods if large number of errors or collisions are detected. So which one to choose? The Cut-through method has the least latency so is usually the best to use with AdderLink Infinity units. However, if the network components and/ or cabling generate a lot of errors, the Store and forward method should probably be used. On higher end store and forward switches, latency is rarely an issue. Layer 2 and Layer 3: The OSI model When discussing network switches, the terms Layer 2 and Layer 3 are very often used. These refer to parts of the Open System Interconnection (OSI) model, a standardized way to categorize the necessary functions of any standard network. There are seven layers in the OSI model and these define the steps needed to get the data created by you (imagine that you are Layer 8) reliably down onto the transmission medium (the cable, optical fiber, radio wave, etc.) that carries the data to another user; to complete the picture, consider the transmission medium is Layer 0. In general, think of the functions carried out by the layers at the top as being complex, becoming less complex as you go lower down. As your data travel down from you towards the transmission medium (the cable), they are successively encapsulated at each layer within a new wrapper (along with a few instructions), ready for transport. Once transmission has been made to the intended destination, the reverse occurs: Each wrapper is stripped away and the instructions examined until finally only the original data are left. So why are Layer 2 and Layer 3 of particular importance when discussing AdderLink Infinity? Because the successful transmission of data relies upon fast and reliable passage through network switches – and most of these operate at either Layer 2 or Layer 3. The job of any network switch is to receive each incoming network packet, strip away only the first few wrappers to discover the intended destination then rewrap the packet and send it in the correct direction. continued
45 INSTALLATION CONFIGURATION OPERATION FURTHERINFORMATION INDEX In simplified terms, the wrapper that is added at Layer 2 (by the sending system) includes the physical address of the intended recipient system, i.e. the unique MAC address (for example, 09:f8:33:d7:66:12) that is assigned to every networking device at manufacture. Deciphering recipients at this level is more straightforward than at Layer 3, where the address of the recipient is represented by a logical IP address (e.g. 192.168.0.10) and requires greater knowledge of the surrounding network structure. Due to their more complex circuitry, Layer 3 switches are more expensive than Layer 2 switches of a similar build quality and are used more sparingly within installations.
46 INSTALLATION CONFIGURATION OPERATION FURTHERINFORMATION INDEX General specifications Casing (w x h x d): 198mm (7.92”) x 44mm (1.76”) x 150mm (6.0”) Construction: 1U compact case, robust metal design Weight: 1.1kg (2.4lbs) Mount kits: Rack mount - single or dual units per 1U slot. VESA monitor / wall mount chassis. Power to adapter: 100-240VAC 50/60Hz, 0.8A, Power to unit: 5VDC 20W Operating temp: 0ºC to 40ºC (32ºF to 104ºF) Approvals: CE, FCC 9pin D-type female9pin D-type female Supported video modes ALIF units support all VESA and CEA video modes. RS232 ‘null-modem’ cable pin-out APPENDIX F - Cable pinouts, video modes and general specifications
47 INSTALLATION CONFIGURATION OPERATION FURTHERINFORMATION INDEX APPENDIX G - Fiber modules and cables To suit your installation layout, two fiber modules are available for the ALIF dual units to suit various fiber optic cables. The specifications for all are summarized in the table below: Fiber TypeFiber sizeFiber Type CodingDistance at 1Gbps Adder part number for SFP module Bar color Conn. type Normal Applications Military Applications Suggested Print Nomenclature OM1(62.5/125) Multimode (TIA-492AAAA) OrangeSlate62.5/125220mSFP-MM-LCBlackLC OM2(50/125)Multimode (TIA-492AAAB) OrangeOrange50/125550m“““ OM3(50/125)Multimode (850 nm Laser-optimized) (TIA-492AAAC) AquaUndefined850 LO 50 /125550m“““ OM4(50/125)Multimode (850 nm Laser-optimized) (TIA-492AAAC) AquaUndefined850 LO 50 /125550m “““ OS1 and OS2(9/125)Single-mode (TIA-492C000 / TIA-492E000) YellowYellowSM/NZDS, SM10KmSFP-SM-LCBlueLC
48 INSTALLATION CONFIGURATION OPERATION FURTHERINFORMATION INDEX Single unit rack brackets The optional single unit brackets (plus four screws), allow a unit to be secured within a standard rack half width slot. IMPORTANT - allow space for airflow The ALIF units and their power supplies generate heat when in operation and will become warm to the touch. Do not place them in locations where air cannot circulate to cool the equipment. When mounting units within a rack chassis, allow a 1/3rd U space (1.5cm) between rows of devices: Do not operate the equipment in ambient temperatures exceeding 40oC. Do not place the products in contact with equipment whose surface temperature exceeds 40oC . 1/3 U (1.5cm) space for cooling APPENDIX H - Mounting options There are several mounting methods for transmitter and receiver units: • The supplied four self-adhesive rubber feet • Optional single unit rack brackets - this page • Optional dual unit rack brackets • Optional VESA bracket mount
49 INSTALLATION CONFIGURATION OPERATION FURTHERINFORMATION INDEX Double unit rack brackets This optional kit comprises four brackets (plus twelve screws) and allows two ALIF units to be mounted side by side and fitted into a 1U rack slot. IMPORTANT - allow space for airflow The ALIF units and their power supplies generate heat when in operation and will become warm to the touch. Do not place them in locations where air cannot circulate to cool the equipment. When mounting units within a rack chassis, allow a 1/3rd U space (1.5cm) between rows of devices: Do not operate the equipment in ambient temperatures exceeding 40oC. Do not place the products in contact with equipment whose surface temperature exceeds 40oC . 1/3 U (1.5cm) space for cooling