Adder RED PSU Manual
Here you can view all the pages of manual Adder RED PSU Manual. The ADDER manuals for Extender are available online for free. You can easily download all the documents as PDF.
Page 1
RED-PSU User Guide Experts in Connectivity Solutions 00330052005A00480055 00360052004F00580057004C005200510056
Page 2
INSTALLATION 1 CONFIGURATION OPERATION FURTHER INFORMATION INDEX Introduction Welcome ................................................................................................................ 2 Protection and control .................................................................................. 2 5VDC converter dongles ............................................................................. 2 Supplied items...
Page 3
INSTALLATION 2 CONFIGURATION OPERATION FURTHER INFORMATION INDEX Introduction Welcome Thank you for choosing the Adder RED-PSU system. In tune with your network, as KVM systems expand so too do their requirements for the reliable supply of power. While individual Adder power adaptors perform well, as devices proliferate they can become unwieldy and difficult to manage. RED-PSU provides the next step in terms of efficiency, reliability and power management. The heart of the RED-PSU system is a...
Page 4
INSTALLATION 3 CONFIGURATION OPERATION FURTHER INFORMATION INDEX SuPPlieD itemS information wallet containing: Four self-adhesive rubber feet Safety document ReD-PSu chassis with 8 or 16 power output ports one or two power module(s) (pre-installed within the chassis) and country-specific power cord(s) Secondary power module Part number: PSU-RED-460W oPtional extRaS Country-specific power cords CAB-IEC-EURO (Central Europe) CAB-IEC-UK (United Kingdom) CAB-IEC-USA (United States)...
Page 5
4 inStallation CONFIGURATION OPERATION FURTHER INFORMATION INDEX Installation location Please consider the following important points when planning the position of the RED- PSU unit: • The RED-PSU main chassis occupies a single 1U (19”) rack slot and r\ equires either one or two (when the redundancy option is used) mains inputs. • For devices that require a 12VDC supply, a 2m link cable (VSC48) is required. • For devices that require a 5VDC supply, small Converter dongles (PSU-RPS-5V) are required...
Page 6
5 inStallation CONFIGURATION OPERATION FURTHER INFORMATION INDEX connectionS The multiple output ports of the RED-PSU each provide power at 12VDC; when powering a 12VDC device, you merely need to use a basic cable (part number: VSC48) . However, if you need to power a 5VDC device, you must use a converter dongle (part number: PSU-RPS-5V) as the link. connect the converter dongle 2.5mm jack to the power input of the device connecting a 12V device Devices that require a 12VDC supply can be...
Page 7
6 inStallation CONFIGURATION OPERATION FURTHER INFORMATION INDEX Fitting/removing a power module The RED-PSU main chassis can accommodate two power modules, although operation is perfectly possible with just one module fitted. The addition of a second module provides redundancy for critical installations. imPoRtant: t o ensure correct and reliable operation, only adder power modules may be used with the ReD-PSu . upon startup, each inserted power module is interrogated by the ReD-PSu and only...
Page 8
7 inStallation CONFIGURATION OPERATION FURTHER INFORMATION INDEX S/FtP screened patch cable link to a network switch network connection The RED-PSU allows remote monitoring and control via a standard network connection. Note: The patch cable used to link with the RED-PSU must be screened to the S/FTP level. t o connect to a network 1 Use a screened patch cable (cross- over or straight connections are both supported) to link the Ethernet 10/100 network port ( ) on the front panel of the main...
Page 9
8 INSTALLATION conFiGuRation OPERATION FURTHER INFORMATION INDEX Configuration a cceSSinG the mana Gement aPPlication Each RED-PSU is configured via its network connections using an intuitive browser-based application, called Redundant Power Supply Manager. This secure, password protected application is accessible by any authorized admin user, located anywhere. to access the management application 1 Use a computer that is directly or indirectly (i.e. via a network switch) connected to the RED-PSU...
Page 10
9 INSTALLATION conFiGuRation OPERATION FURTHER INFORMATION INDEX the StatuS & contR ol PaGe This opening page of the manager application provides a useful real time overview of the power input and output status. Using this page you can quickly ascertain the key metrics related to the power modules (e.g. temperatures, fan speeds, mains and output currents) as well as each output port. Additionally, you can monitor, name and control each output port individually. to change the status of a single...