ADDER ePower Switch 8 Slave Manual
Have a look at the manual ADDER ePower Switch 8 Slave Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 78 ADDER manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
ePowerSwitch 8XS User guide Version 02 2011 www.neol.com
Page | 1 ePowerSwitch 8XS © Copyright by NEOL S.A.S - 4 Rue Nationale, 67800 BISCHHEIM, France Printed in France All rights reserved. No part of this documentation, accompanying software or other components of the described product may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying and recording, for any purpose other than the personal use of the purchaser without the express written permission of NEOL S.A.S. This documentation, the ePowerSwitch 8M+ R2, its peripherals, accessories and accompanying software were produced with great care, yet errors are possible. NEOL S.A.S assumes no responsibility for errors within the documentation, the hardware or the software. NEOL S.A.S reserves the right to change programs or the documentation from time to time without informing the user, errors and omissions excepted. Trademarks Neol and ePowerSwitch are registered trademarks of NEOL S.A.S. All other brand names and product names used in this book are trade names, service marks, trademarks, or registered trademarks of their respective owners.
Page | 2 User Guide CONTENTS SAFETY INSTRUCTIONS: To be read before use! ...................................................................................... 3 Consignes de sécurité : à lire avant utilisation ! ............................................................................................ 4 1. DESCRIPTION .......................................................................................................................................... 5 1.1. Package list ........................................................................................................................................ 5 1.2 Compatibility tables ............................................................................................................................. 5 3. Diagram ..................................................................................................................................................... 6 3.1. Front panel ......................................................................................................................................... 6 3.2. Back .................................................................................................................................................... 7 4. Connection to a Master ............................................................................................................................. 8 5. Controlling the Satellite power outlets through the Master Web Server.................................................. 10 6. Controlling the Satellite power outlets using a Terminal Connection ...................................................... 11 6.1. Using the RS232 port ....................................................................................................................... 11 6.2. Using the RS485 port ....................................................................................................................... 11 6.3. Commands ....................................................................................................................................... 11 6.3.1. Controlling of the power outlet(s) ........................................................................................... 12 6.3.2. Reading out the power outlet status ....................................................................................... 13 6.3.3. Setting of the power up delays ............................................................................................... 14 6.3.4. Reading out of the power up delay(s) .................................................................................... 14 6.3.5. Setting the restart delays ....................................................................................................... 15 6.3.6. Reading out of the restart delays ........................................................................................... 15 6.3.7. Setting the power up default status ........................................................................................ 16 6.3.8. Reading out the power up default status ............................................................................... 16 6.3.9. Reading out the switching counter values of the relays ......................................................... 17 6.3.10. Resetting the switching counter values of the relays ........................................................... 18 6.3.11. Restoring to factory settings ................................................................................................. 18 Technical Data ............................................................................................................................................. 19 Statement of Conformity .............................................................................................................................. 20
Page | 3 ePowerSwitch 8XS SAFETY INSTRUCTIONS: To be read before use! NOTE • The ePowerSwitch devices can only be installed by qualified people with the following installation and use instructions. The manufacturer disclaims all responsibility in case of a bad utilization of the ePowerSwitch devices and particularly any use with equipments that may cause personal injury or material damage. • This equipment is designed to be installed on a dedicated circuit that must have a circuit breaker or fuse protection. • The electrical power sockets used to plug the power cords of the ePowerSwitch devices must be close to the ePowerSwitch devices and easily accessible. • Check that the power cords, plugs and sockets are in good condition. • The ePowerSwitch devices can only be connected to three-wire 230 VAC (50-60Hz) sockets. • Always plug the ePowerSwitch devices into properly grounded power sockets (two poles plus ground). • Never exceed 10 Amp total load for each group of 4 power outlets of an ePowerSwitch device. • The ePowerSwitch devices are intended for indoor use only. Do NOT install them in an area where excessive moisture or heat is present. • Always disconnect the 2 (two) power cords of the ePowerSwitch device if you want to intervene on the ePowerSwitch device or on the equipment powered from the ePowerSwitch device. • The power outlets of the ePowerSwitch devices are not circuit breakers! If you want to intervene on equipments connected to an ePowerSwitch device you must disconnect these equipments from the ePowerSwitch device. • Do NOT attempt to disassemble the ePowerSwitch devices, they contain potentially hazardous voltages. • The ePowerSwitch devices contain no user serviceable parts and repairs are to be performed by factory trained service personnel only. • Always use a shielded cable for the Ethernet connection.
Page | 4 User Guide Consignes de sécurité : à lire avant utilisation ! Remarque • Les équipements ePowerSwitch ne peuvent être installés que par un personnel qualifié. Le fabricant décline toute responsabilité en cas de mauvaise utilisation des équipements ePowerSwitch et tout particulièrement en cas d’utilisation avec des équipements pouvant occasionner des blessures corporelles ou des dommages matériels. • Les équipements ePowerSwitch sont destinés à être installés sur un ou plusieurs circuits électriques dédiés protégés par des disjoncteurs ou des fusibles. Les prises secteur utilisées pour brancher les cordons secteur d’alimentation des équipements ePowerSwitch doivent être à proximité des équipements ePowerSwitch et facilement accessibles. • Vérifiez que les cordons secteur d’alimentation, les connecteurs et les prises secteur sont en bon état.Les équipements ePowerSwitch ne peuvent être connectés qu’à des prises secteur à 3 conducteurs (2 prises + terre) 230 VAC (50-60Hz). • N’utilisez que des prises secteur correctement mises à la terre (deux prises + terre) pour brancher les câbles secteur des équipements ePowerSwitch. • Ne jamais dépasser un courant total de 10 Amp pour chaque entrée secteur des équipements ePowerSwitch. • Les équipements ePowerSwitch sont destinés à une utilisation intérieure. NE les installez JAMAIS dans un endroit où règne une humidité ou une chaleur excessive. • Débranchez TOUJOURS les 2 cordons secteur d’alimentation des équipements ePowerSwitch si vous souhaitez intervenir sur les équipements ePowerSwitch ou sur les appareils alimentés au travers des équipements ePowerSwitch. • Les prises secteur des équipements ePowerSwitch ne sont PAS des coupe-circuits ! Si vous souhaitez intervenir sur les appareils alimentés au travers des équipements ePowerSwitch vous devez IMPERATIVEMENT débrancher ces appareils des équipements ePowerSwitch. • Ne démontez JAMAIS lePowerSwitch, il y a risque de choc électrique ! • Les équipements ePowerSwitch ne contiennent pas de pièces nécessitant une maintenance. Les éventuelles réparations ne peuvent être faites que par un personnel habilité et formé par le fabricant. • Utilisez toujours un câble blindé pour la connexion Ethernet. Français
Page | 5 ePowerSwitch 8XS 1. DESCRIPTION ePowerSwitch 8XS is a power distribution and control unit that enables power management of 8 devices through an RS-232 or RS-485 connection. The ePowerSwitch 8XS has two separate power inputs of 10 Amp to increase the security and the load available on the power outlets. This device is intended to be connected to an ePowerSwitch Master or to the VizioGuard Environmental Monitoring Systems. Thanks to the RS232 and RS485 interfaces and its easy to use ASCII protocol, the ePowerSwitch Satellite is also the ideal solution to control power outlets through the serial connection of a KVM switch, a console server or a PC. The number of the controlled power outlets can be extended by connecting the ePowerSwitch Satellite unit to an ePowerSwitch Master 4M+, 8M+, 8M+R2, 8M+/32 or VizioGuard. 1.1. Package list The following items are included: ‰ 1 ePowerSwitch Satellite 8XS ‰ 2 power cables, 230 V / 10 Amp, length 1.80 Meter ‰ 1 RJ45 M/M, 0.50 Meter ‰ 1 serial cable SUB-D 9 points male/female, length 1.80 Meter ‰ CD including this user guide ‰ 1 quick installation guide 1.2 Compatibility tables Up to 4 ePowerSwitch 8XS Satellite from V. 2.05 can be connected to: ePowerSwitch M8 from V.1.1.0.0 ePowerSwitch 4M+ from V.2.1.0.0 ePowerSwitch 8M+ from V.1.0.0.3 ePowerSwitch 8M+R2 from V.2.1.0.0 ePowerSwitch 8M+/32 from V.1.0.0.0 VizioGuardTiny from V. Up to 16 ePowerSwitch 8XS Satellite from V. 2.05 can be connected to: ePowerSwitch 8XM from V.2.0.1.3 VizioGuard from V.3.0.0.1
Page | 6 User Guide 3. Diagram 3.1. Front panel A B 1 2 3 4 5 6 7 8 (LEDs) A Green. Lights up when power applied on Group A B Green. Lights up when power applied on Group B 1 Red. Status of power outlet 1 (On/Off) 2 Red. Status of power outlet 2 (On/Off) 3 Red. Status of power outlet 3 (On/Off) 4 Red. Status of power outlet 4 (On/Off) 5 Red. Status of power outlet 5 (On/Off) 6 Red. Status of power outlet 6 (On/Off) 7 Red. Status of power outlet 7 (On/Off) 8 Red. Status of power outlet 8 (On/Off) Dip Switches 1 - 4: physical address of device 5 - 6: xBus termination RS232 (SUB-D 9F Connector) RS232 serial port with DB-9 female connector Pinout 2 = RxD 3 = TxD 5 = Gnd xBus (RS485) These connectors are used for cascading xBus devices together (ePowerSwitch Satellite, sensors, extension modules, etc.). Maximal TOTAL line length: 200 meters SUB-D9F Connector Terminal connection RJ45 Connectors xBus RS485 Cascading connection LEDs A = Power supply A B = Power supply B 1 - 8 = Status of outlets 1 - 8 Dip Switches 1 - 4: physical address of device 5 - 6: xBus termination
Page | 7 ePowerSwitch 8XS 3.2. Back Power input B 230 VAC – 10 Amp Power outlets (Group B) Power outlets 5 – 8 230 VAC max 10 Amp Power outlets (Group A) Power outlets 1 – 4 230 VAC max 10 Amp Power input A 230 VAC – 10 Amp
Page | 8 User Guide 4. Connection to a Master Make sure that all the ePowerSwitch devices are powered off. Connection Instructions 1. Connect the appropriate link-up cable to one of the xBus connector of the ePowerSwitch Master and to one of the xBus connector of the ePowerSwitch 8XS. To cascade several Satellites, link the second xBus connector of a Satellite with one of the xBus connector of the next Satellite. Master unit Link-up cable to the first satellite Link-up cable to the next satellites EPS M8 RJ9M - DB9M (Réf RJ9-DB9M 180, must be ordered separately) (up to 4 Satellite units) RJ45M - RJ45M or RJ11M - RJ45M (see supplied cable set) EPS 4M+ EPS 8M+ EPS 8M+ R2 VizioGuardTiny RJ45M - RJ45M (use supplied cable) (up to 4 Satellite units) RJ45M - RJ45M EPS 8XM VizioGuard RJ45M - RJ45M (use supplied cable) (up to 16 Satellite units) RJ45M - RJ45M 234 DCDRY CONTACTSMAX 24VDC - 20mA12VDC AUXPOWER SUPPLY I/OA123410/100 Li nk100 RS232x BusTe r mSB56781 RS232Sl ct Te r m867 x Bus 345Power2B1A RS232Sl ct Te r m867 x Bus 345Power2B1A