40 5.2. Technical Data Network standards: IEEE 802.3, 10 / 100 BASE-T Network protocols: TCP/IP, HTTP Network connection: RJ-45 connector for STP CAT5 Max. network cable length 100 meters Serial connection: RS232, SUB-D 9 female Operating temperature: 0°C to +40°C Operating humidity: 10% to 80% RH (not condensing) Dimensions (LxDxH): 185 x 103 x 43 mm Weight: 1 kg Approvals: CE, EN 60950-1, EN 55022, EN 55024 5.3. Commonly used Ports TCP 80: This port is used for http connections. UDP 123: This port is used to allow time synchronization over NTP (Network Time Protocol). UDP 161: This port is used for SNMP Requests. UDP 162: This port is used for SNMP Traps. UDP 514: This port is used to deliver Syslog messages.
41 5.4. Syslog Messages: Severity Level Definitions The Emergency level is the most severe type of message generated by ePowerSwitch 1GR2 and the Debug severity level is the least severe one. Severity Level 0, Emergency: The following messages appear at severity 0: - Continuous error! Severity Level 1, Alert: The following messages appear at severity 1: - Settings have been reinitialized through the serial connection - ePowerSwitch 1G R2 does not respond Severity Level 2, Critical: The following messages appear at severity 2: - file config corrupted: restoring default values Severity Level 3, Error: ePowerSwitch 1G R2 doesnt generate Severity Level 3. Severity Level 4, Warning: The following messages appear at severity 4: - Settings have been changed through the serial connection - Settings have been changed through the network by User name Severity Level 5, Notice: The following messages appear at severity 5: - System has been restarted through the serial connection - Power Supply restored - Rule (number) : Outlet (number) has been switched ON Severity Level 6, Informational: The following messages appear at severity 6: - System has been started - Date & Time have been synchronized to a Network Time Server - User name : Outlet (number) has been switched ON - Session opened by user name Severity Level 7, Debug: ePowerSwitch 1G R2 doesnt generate Severity Level 7.
42 STATEMENT OF CONFORMITY All modifications reserved STATEMENT OF CONFORMITY NEOL S.A.S. declares that this equipment is in compliance with the Electromagnetic Compatibility Directive 89/336/EEC and the Low Voltage Directive 73/23/EEC Application of Council Directive: 2004/108/EEC Standards to Which Conformity declared: EN 60950-1, EN 55022, EN 55024 Manufacturers Name and Address: NEOL S.A.S 4 Rue Nationale 67800 BISCHHEIM -FRANCE Type of Equipment: Power distribution and control unit Type Designation: ePowerSwitch 1GR2 Reference: ePowerSwitch 1GR2 Years of Manufacture: 2011 We, the undersigned, hereby declare that the equipment specified above conforms to the above directives. Bischheim, 17th February 2011 Paul REYSER, General Manager NEOL S.A.S.