    Have a look at the manual Adam Equipment GBC Bench Counting Scales GBCGFCREVB4 User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 35 Adam Equipment manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							 P a g e 19                       © Adam Equipment Company 2014 
     Data Format-Normal Output:  
    Data Format- Memory Recall Print:   
      
      
    DATE            12/09/2006 
    TIME            14:56  
      
    GROSS Wt       1.234 Kg    
     Net Wt. if net weight is displayed 
    Unit Wt.         123 g     Kg or g for metric weights and lb for pounds. 
    Pcs               10 pcs 
                        
    Includes 2 line feeds with carriage return 
               
    at beginning and end of  the form 
      
    DATE            12/09/2006 
    TIME            14:56 
     
    ------------------ 
    TOTAL 
    No.                  5 
    Wt.           1.234 Kg   
    Pcs              10 pcs 
                            
     Includes 1 line feed 
    ------------------ 
               
    2 line feeds, carriage return 
        
    						
    							 P a g e 20                       © Adam Equipment Company 2014 
    Data Format- Continuous Print:  
      
    In other languages the format is the same but the t ext will be in the language selected. 
    See Section 9.2 
    Description  ENGLISH  FRENCH  GERMAN   SPANISH 
    Print  gross  
    weight  Gross Wt  Pds Brut  Brut-Gew  Pso Brut 
    Net weight 
    Net Wt.  Pds Net  Net-Gew  Pso Net 
    Weight  per  
    unit counted
     
    Unit Wt.  Pds unit  Gew/Einh  Pso/Unid 
    Number  of  
    items 
    counted Pcs  Pcs  Stck.  Piezas 
    Number  of  
    weighings   
    added  to  
    subtotals No.  Nb.  Anzhl  Num. 
    Total  weight  
    and  count  
    printed 
    Total  Total  Gesamt  Total 
    Print date 
    Date  Date  Datum  Fecha 
    Print time Time  Heure  Zeit  Hora 
         
    ST,GS,      0.9080 kg  
    U.W.      0.90798 g/pcs 
    PCS          1000 pcs  
              
    Includes 2 line feeds with carriage return 
                       between sets of data 
               
    						
    							 P a g e 21                       © Adam Equipment Company 2014 
    9.1   INPUT COMMANDS FORMAT  
    The  scale  can  be  controlled  with  the  following  comm ands.  The  commands  must  be 
    sent  in  upper  case  letters,  i.e.  “T”  not  “t”.  Press   the  Enter  key  of  the  PC  after  each 
    command. 
    T    Tares  the  scale  to  display  the  net  weight.  This  is 
    the  same  as 
    pressing  [Tare] key. 
    Z    Sets the zero point for all subsequent weighing. Th
    e display shows 
    zero. Same as pressing the  [Zero] key. 
    P    Prints  the  weight,  unit  weight  and  totals  same  as  p
    ressing  the 
    [Print]  key.  
    R  Recall and Print,   Same as if first the  [MR] key and then the  [Print] 
    key  is  pressed.  Will  display  the  current  accumulate d  memory  and 
    print the total results. 
    C  Same  as  pressing  [MR]  first  and  then  the  [CE]  key  to  erase  the 
    current memory. 
      
    						
    							 P a g e 22                       © Adam Equipment Company 2014 
    9.2  RS-232 SETUP  
    The  RS-232  interface  uses  parameters  set  by  the  use r  for  language,  baud  rate  and 
    date format.   
    Press and hold the  [Print] key for 4 seconds to access the parameters.  
    Press  [U. Wt./Units]  to scroll through the options and  [Tare] to confirm the change 
    and then advance to the next parameter.  
    When a parameter is entered by pressing  [Tare], the displays will guide you through 
    the parameter selected and the options available.  
    The parameters and their functions are:  
    Displays  Options  Functions 
    Weight  Unit Weight Count 
    Port 
     
    on  On 
    oFF 
    Enable  or  disable  the  RS- 
    232 interface.  
    9600 bPS  600 
    1200  
    2400 
    4800 
    9600 
    19200 
    Set baud rate.  
    Print  mAn  Cont to PC 
    Print  Auto  
    Print mAn  
     
    Select  printing  options  for  
    continuous  printing,  print  
    automatically  or  printing  
    manually. 
    AC mAn  AC Auto 
    AC mAn  
    AC oFF 
    Select  the  operation  of  
    accumulating  
    automatically, manually or 
    turned off. 
    LAnG  EnGLiS EnGLiS 
    FrEnCH  
    GErMAn 
    SPAniS
      
    Select  Language  for  
    printing.  
      
    						
    							 P a g e 23                       © Adam Equipment Company 2014 
    The  scale  will  perform  the  following  functions  depe nding  on  the  Accumulation  and  Print 
    settings:  
     
     
    ACCUMULATION FUNCTIONS 
     
    PRINT  
    FUNCTIONS
     AC Auto  AC mAn  AC oFF 
    Print Auto  Accumulate and print  
    automatically  
    Print automatically ; 
    Accumulate  and  print  
    when
     [M+]  is pressed 
      Print  automatically,  
    [M+]
      key  has  no 
    function 
    Print mAn  Automatically  
    Accumulate  but  not print, Print only when  
    [Print] 
    key pressed 
     
    Accumulate  and  print  
    when  [M+]  or  [Print]   is 
    pressed   Print  when 
    [Print] key 
    is  pressed,  [M+]  key 
    has no function 
    Cont to PC  Print  continuously  
    and  accumulate 
    automatically  when 
    stable , 
    [Print] key no 
    function  Print  continuously  and 
    accumulate  when
      [M+]  is 
    pressed,  [Print]  key  no 
    function 
    Print continuously , 
    [M+]  and [Print]   key 
    have no function 
      
        
    						
    							 P a g e 24                       © Adam Equipment Company 2014 
    9.3   REAL TIME CLOCK SETUP 
    The Real Time Clock (RTC) is used only for the RS-2 32 output.  The Date and Time can 
    be set as required.  The scale will keep the clock  running even when the power is off. 
    Setting up the clock  
    ·  Press  and  hold  the   [CE]  key  for  4  seconds,  release  when  the  date  and  time  is 
    displayed.  The initial displays show the current d ate and time set.   
    “ rtC       “  “11,14,06”   “16,41,35” 
    ·   Press the  [CE] key to change the date and time.  The display will  show the 
    current time in the format, “H-m-S”. 
    “timE”  “H-m-S”   “142929”   or if no time has been set show  “000000”   
    ·   Enter the time using the numeric keys using a 24 ho ur clock format, 3:41PM is 
    “154100”. 
    “timE”  “H-m-S”   “154100”   new time overwrites the old 
    ·   Press the  [Tare] key to accept the time.  The display will show the  current date 
    format.   
    “dAtE”  “y-m-d” 
    ·   Press the [ U.Wt./Unit]  key to change the date format. Available formats a re: 
    “Y-m-d”    year, month, day 
    “m-d-Y”    month, day, year 
    “d-m-Y”    day, month, year 
    ·   Press the  [Tare] key to accept the chosen format and then enter the  date in this 
    format.   
    “dAtE”  “m-d-y” “051209”   note current date is in current format, will show 
    000000 if no date has been set. 
    ·   Press the  [Tare] key to accept the date. 
    An error code will be shown if the time (Err 1) or  the date (Err 2) is not the permissible 
    values.   For example, 34th day of a month is an in valid entry.  
    						
    							 P a g e 25                       © Adam Equipment Company 2014 
      
    9.4  AUTO
     SLEEP FUNCTION 
    This  function  may  be  enabled  or  disabled  by  the  use r.  If  enabled,  when  the  scale  is 
    not  used  for  some  time  (as  pre-set  by  the  user  unde r  this  function)  it  automatically 
    switches off. To set this parameter- 
    ·  Press  and  hold  the   [Zero]  key  for  4  seconds,  release  when  the  display 
    shows  “SLEEP nodE” . 
    ·   Press  [U/Wt/Unit]  key to scroll through the auto sleep values. 
    “0”    Auto sleep mode disabled 
    “1”      Auto sleep after 1 minute 
    “5”    Auto sleep after 5 minutes  
    “10”    Auto sleep after 10 minutes 
    ·   Press  [Tare]  to set the value. The scale returns to zero. 
     
     
    10.0  BATTERY AND BACKLIGHT OPERATION 
    10.1  BATTERY 
    ·  The scales can be operated from the battery, if des ired. The battery life 
    is approximately 70 hours. 
    ·   When  the  battery  needs  charging  the  battery  symbol  will  appear  to  be 
    empty.    The  battery  should  be  charged  as  possible.  Once  the  “LO  bAT” 
    message is shown the scale will still operate for a bout 10 minutes after 
    which it will automatically switch off to protect t he battery. 
    ·   To  charge  the  battery,  simply  apply  power  to  the  sc ale.  The  scale  does 
    not need to be turned on.  
    ·   The battery should be charged for at least 12 hours  for full capacity. 
    ·   Just above the  “Unit Weight” display is an LED to indicate the status of 
    battery charging.  When the scale is plugged into t he  mains power, the 
    internal  battery  will  be  charged.    If  the  LED  is  gr een  the  battery  is  fully 
    charged.  If it is red, the battery is nearly disch arged and yellow indicates 
    the battery should be charged longer, preferably ov ernight. 
    ·   If  the  battery  has  not  been  used  properly  or  it  is  used  for  a  number  of 
    years  it  may  eventually  fail  to  hold  a  full  charge.   If  the  battery  life 
    becomes unacceptable then contact your supplier.  
    						
    							 P a g e 26                       © Adam Equipment Company 2014 
    10.2  BACKLIGHT FOR LCD 
    ·   The backlight of the LCD can be set to be- 
    “1” : ON at all the time,  
    “2” : ON only when a weight is placed on the scale or  
    “3” : Turned off.    
    ·   To set the backlight press and hold  [Pst] key for 4 seconds.   
    ·   The  weight  display  will  show  “EL  xx”  where  xx  is  the  current  setting  for 
    the backlight.    
    Press  [U. Wt./Units]  to scroll through the options. 
    “EL on”  Sets the backlight to be on at all times. 
     
    “EL Au” Sets  the  backlight  to  operate  automatically  when  a  
    weight is placed on the scale or a key is pressed. 
     
    “EL OFF” Sets the backlight to be off. 
     
    Press  the  [Tare]  key  to  store  the  value  or  press  the   [Zero]  key  to  escape  from  this 
    setting and return to weighing. 
     
      
    						
    							 P a g e 27                       © Adam Equipment Company 2014 
    11.0  ERROR CODES 
    During the initial power-on testing or during opera tion, the scale may show an error 
    message.  The meaning of the error messages is desc ribed below. 
    If  an  error  message  is  shown,  repeat  the  step  that  caused  the  message,  turning  the 
    balance  on,  carry  out  the  calibration  or  other  func tions.  If  the  error  message  is  still 
    shown contact your dealer for further support.     
    ERROR CODE  DESCRIPTION  POSSIBLE CAUSES 
    Err  1  Time input error.  Tried  to  set  an  illegal  time,  i.e
    . 
    26hours  
    Err  2  Date input error  Tried  to  set  an  illegal  date,  i.e.
      36th 
    day  
    Err  4  Initial  Zero  is  greater  
    than  allowed  (typically 
    4%  of  the  maximum  
    capacity) when power is  
    turned  on  or  when  the  
    [Zero]
     key is pressed,  Weight  is  on  the  pan  when  turning  
    the scale on.  
    Excessive  weight  on  the  pan  when  
    zeroing the scale.  
    Improper calibration of the scale. 
    Damaged load cell. 
    Damaged Electronics. 
    Err 6 
    A/D count is not correct  
    when  turning  the  scale  
    on.  Platform is not installed.  
    Damaged Load cell.  
    Damaged Electronics.   
    diSPEr 
    Shows  when  a  number  
    is  too  large  tot  fit  the  
    display  The accumulated totals for weight or  
    count  exceed  999999.    The  data  on  
    RS232 is still shown accurately 
      
        
    						
    							 P a g e 28                       © Adam Equipment Company 2014 
    12.0  SERVICE PARAMETERS 
    12.1  USING “0000” TO ENTER THE CALIBRATION PARAMETER 
    ·   Press  the   [Tare]  key  during  the  display  counting  when  turned  on.  Th e 
    display will ask for a code number,  “Pin    “ on the Weight Display.  
    ·   Enter the number  0000 when  “Pin  “ is displayed and  then press  [Tare]. 
    If  another  PIN  number  has  been  previously  stored  en ter  that  number 
    instead.  
    ·   The displays will show the first parameters, called  “F1”  “CAL” .   
    ·   To  select  another  parameter  press  the  [U.Wt./Units]  key  to  advance 
    through the parameters.   
    ·   Press the  [Tare] key to enter a parameter.   
    ·   To exit a parameter, press the  [Zero] key.   
    ·   The Weight window will show the parameter number an d the Unit Price 
    and Count windows will show the word describing the  function.   
    ·   When  a  parameter  is  entered  by  pressing  the   [Tare] key,  the  displays 
    will  guide  you  through  the  parameter  selected  and  t he  options 
    available. 
    The parameters available are:  
    “F1”   “CAL”
          To enter the Calibration 
    “F2”  “Pin”        To set a new Pin number for access 
    “F3”  “Unit”       Enable Weighing Units 
      
    						