Adam Equipment Coin Counting Scale CCEUrevA4 User Manual
Here you can view all the pages of manual Adam Equipment Coin Counting Scale CCEUrevA4 User Manual. The Adam Equipment manuals for Scale are available online for free. You can easily download all the documents as PDF.
Page 11
9 | P a g e © Adam Equipment Company 2009 2.6 BACKLIGHT OPERATION The LCD display has a backlight that operates autom atically. To maximise the battery life it may be necessary to tu rn the backlight off. Hold the [Print] key for 4 seconds to enter the backlight control mode. Use the [MC / ] key to change the setting for the backlight to OFF, ON (set to on for full time) or AUTO (set to o n only when there is a weight on the scale). 2.7 TEMPORARY...
Page 12
10 | P a g e © Adam Equipment Company 2009 “Y-m-d ” year, month, day “ m-d-Y ” month, day, year “ d-m-Y ” day, month, year Press the [Total/ ] key to accept the chosen format and then enter the date in this format. Press the [Total/ ] key to accept the date. An error code will be shown if the time ( Err 1) or the date ( Err 2) is not the permissible values. For example, 34 th day of a month is an invalid entry.
Page 13
11 | P a g e © Adam Equipment Company 2009 3.0 BASIC OPERATION 3.1 ZEROING THE DISPLAY Press the [>ZZZ
Page 14
12 | P a g e © Adam Equipment Company 2009 When both the product and container are removed the Quantity and TOTAL display will show bars “- - - - -“ as the weight i s below zero. If a different container is to be used, remove this negative tare value by pressing the [Tare] key once more. Any time the weight is negative, only bars will be shown in the TOTAL display “- - - - - “. 3.3 COIN COUNTING To count coins simply place the...
Page 15
13 | P a g e © Adam Equipment Company 2009 3.4 MEMORY ACCUMULATIONS When the coins have been counted it is possible to store the results of this sample into memory by pressing [M+]. The displays will show a number corresponding to th e item number in memory ( Denomination display “1 ”) and the total quantity of coins counted in memory ( Quantity display) and the total value of coins that have been stored into mem ory (TOTAL...
Page 16
14 | P a g e © Adam Equipment Company 2009 Press [M+] “ 3 ” “ 498” “ 175.50” After 2 seconds the scale will return to normal ope ration. The weight on the scale must return to zero before anot her value is allowed to be stored into memory. NOTE : Tokens cannot be added to memory as they do not h ave a value associated with them. If tokens are to be added to memory with coins, an error message will be displayed: “ ErrOr...
Page 17
15 | P a g e © Adam Equipment Company 2009 3.5 MEMORY RECALL Pressing the [MR] key will allow you to view each set of data stored into the memory. The first time [MR] is pressed the first set of data is shown with Denomination window showing “ ≡ 1 ≡” for 1 second followed by the Denomination , Quantity and TOTAL windows showing the quantity and value for this first item. “ 1 ” “ ” “ ” for 1 second and then “...
Page 18
16 | P a g e © Adam Equipment Company 2009 4.0 RS-232 INTERFACE The Scale includes a RS-232 output as standard. The RS-232 allows a record to be sent to a serial printer as work is do ne on the scale. 4.1 RS-232 OUTPUT The RS-232 interface is bi-directional with command s that function similar to some of the front panel keys and other commands to input data into the scale for coin weights, denominations and symbols used. The parameters for the RS-232...
Page 19
17 | P a g e © Adam Equipment Company 2009 A display produced as shown in the previous example is as follows: “ 0.20 ” “ 285” “ 57.00” Press [M+] “ 1 ” “ 285” “ 57.00” Printed record shows as follows: Any time the [Total / ] key is pressed the current totals held in memory ar e printed. After the 2 nd weighing in the previous sample, the printed recor d shows as follows: Date: 2009/01/05 Time:...
Page 20
18 | P a g e © Adam Equipment Company 2009 The [MC/ ] key is active when the total values are displayed. If [MC/ ] is pressed the memory will be cleared. After 2 seconds the scale will return to normal ope ration. The [Print] key will record a list of all sets of data stored in the memory and the total amounts. For the sample above, the print ed record is: Date: 2009/01/05 Time: 12:23:15 Record 1 Denomination 0.20...