© Adam Equipment Company 2009 A dam Eq\bipme\ft CC EU Coin Co\bnt Sc\fle (P.N. 9659, Revisio\f A4, October 2009)
© Adam Equipment Company 2009 Easy Reference: Model name of the scale: Serial number of the unit: Software revision number (Displayed when power is first turned on): Date of Purchase: Name of the supplier and place:
1 | P a g e © Adam Equipment Company 2009 CONTENTS 1.0 INTRODUCTION ....................................... ............................................................... 3 1.1 FEATURES ........................................... ................................................................ 3 2.0 SET UP............................................. ........................................................................ 4 2.1 LOCATING AND PROTECTING YOUR SCALE................. .................................. 4 2.2 DISPLAY WINDOWS.................................... ........................................................ 5 2.3 KEY DESCRIPTIONS ................................... ........................................................ 6 2.4 SELECT EURO or STERLING COINS ...................... ........................................... 8 2.5 BATTERY CHARGING ................................... ...................................................... 8 2.6 BACKLIGHT OPERATION................................ .................................................... 9 2.7 TEMPORARY WEIGHT DISPLAY ........................... ............................................. 9 2.8 SETTING DATE AND TIME .............................. .................................................... 9 3.0 BASIC OPERATION.................................... ........................................................... 11 3.1 ZEROING THE DISPLAY ................................ ...................................................11 3.2 TARING ............................................. ................................................................. 11 3.3 COIN COUNTING ...................................... ......................................................... 12 3.4 MEMORY ACCUMULATIONS ............................... ............................................. 13 3.5 MEMORY RECALL ...................................... ....................................................... 15 4.0 RS-232 INTERFACE ................................... ........................................................... 16 4.1 RS-232 OUTPUT ...................................... .......................................................... 16 4.2 PRINTING ........................................... ................................................................ 16 4.3 INPUT COMMANDS ..................................... ...................................................... 19 5.0 PARAMETERS ......................................... .............................................................. 20 5.1 SETTING COIN WEIGHT ................................ ...................................................20 5.1.1 Procedure .......................................... .......................................................... 21 5.2 DETERMINING NEW COIN OR TOKEN WEIGHTS .............. ............................ 23 5.2.1 Procedure .......................................... .......................................................... 23 5.3 SECURED FEATURES ................................... ...................................................24 5.4 WEIGHING PARAMETER FUNCTIONS ....................... ..................................... 25 5.4.1 F1 F1F1 F1 - Baud Rate Setting ................................ ...................................................25 5.4.2 F2 F2F2 F2 - PARITY ........................................... ....................................................... 27 5.4.3 F3 F3F3 F3 - SLEEP............................................ ........................................................ 28 5.4.4 F4 F4F4 F4 - Weight Calibration ............................... ...................................................29 5.4.5 F5- Access Code Number ............................... ............................................. 30 5.4.6 F6 F6F6 F6 - Language ......................................... ...................................................... 31 6.0 SECURE PARAMETERS .................................. ..................................................... 33 6.1 SETTING UP SECURED PARAMETERS ...................... .................................... 33 6.1.1 F7- ENABLE EURO / STERLING CHANGE USING THE [€/£] KEY............. 34 6.1.2 F8- Denomination Values .............................. ............................................... 34 6.1.3 F9- Linearity Calibration............................ .................................................... 36 6.1.4 F10- Factory Calibration Value ........................ .............................................. 38 6.2 OTHER SETTINGS ..................................... ....................................................... 40 6.2.1 Restore Factory Calibration ........................ ................................................. 40 6.2.2 Shortcut to Calibration without using Functions .... ....................................... 40 7.0 ERROR MESSAGES ..................................... ........................................................ 41 8.0 SPECIFICATIONS..................................... ............................................................. 42 9.0 WARRANTY STATEMENT ................................. ...................................................43
3 | P a g e © Adam Equipment Company 2009 1.0 INTRODUCTION The CC Coin Counting Scale provides accurate, fast and versatile method of counting coins and determining the value of a group of coins. It can also be used to count tokens with a weight that is determin ed by the user. 1.1 FEATURES CCxx-20 Weighing Automatic tare Coin/token Counting Memory Accumulation Stainless steel weighing platform Level indicator with adjustable leveling feet Colour coded, sealed, keypad Large liquid crystal displays (LCD) Displays for Denomination , Quantity and TOTAL value Battery operated for portability 50+ hours battery life when fully charged The scales can be upgraded when new coins are released Tokens can be counted Standard bi-directional RS-232 Date and time printed Select Euro or Sterling Denominations
4 | P a g e © Adam Equipment Company 2009 2.0 SET UP 2.1 LOCATING AND PROTECTING YOUR SCALE In order to keep your balance functioning at its be st we suggest that you do the following: Avoid extremes of temperature. Do not place in dire ct sunlight or near air conditioning vents. Make sure the scale is located on a strong table an d free from vibration. Avoid unstable power sources. Do not operate near l arge users of electricity such as welding equipment or l arge motors. Do not let the balance battery go flat – if you are not using it for a long time you should charge the batt ery up periodically to make sure the battery dose not lose its charge. Keep free from vibration. Do not place near heavy o r vibrating machinery. Avoid high humidity that might cause condensation, and keep away from direct contact with water. Do not place near open windows, air-conditioning ve nts or fans that may cause a draught and unstable readings . Keep the scales clean, and do not stack material on the scale / balance when it is not in use.
5 | P a g e © Adam Equipment Company 2009 2.2 DISPLAY WINDOWS The Denomination window shows the current denomination that has bee n selected, an arrow will indicate when the scale is at zero (ZERO) and when the weight is stable ( STAB) or if the scale has been tared ( Net) and is displaying a net weight. EURO or STERLING Display The left most digit will show a symbol for Euro ( E EE E ) when selected. For example: When the scale has been changed to show Sterling co ins the coin value will shift to the left digits and the Pounds Sterling sy mbol (P PP P ) will be on the right digit. The Quantity window displays the number of coins counted. An ar row will show whether the weight of Euro style coins (€ Euro) or Sterling style coins ( £ Sterling ) was used to count them. The TOTAL window shows the value of the coins counted. An a rrow will also indicate when a value has been stored in memory ( MEMORY). E 0.50 0.50
6 | P a g e © Adam Equipment Company 2009 2.3 KEY DESCRIPTIONS The keypad has 20 keys. Other keypads may be used f or different counties or applications. The following are used for parameter entry: Function [Total] , ENTER for completing an entry [MC] , increment the value being entered or move to the next parameter [MR] , Move active digit to next available digit [CE] ESCAPE back to normal operation
7 | P a g e © Adam Equipment Company 2009 Other Keys are: [0.01] up to [2.00] and [T1] to [T3] keys Select the denomination of coins or tokens to be co unted. [0] to [9] keys Numeric keys to set values during special applicati ons. [CE/Esc] Used to clear a coin denomination. [€ / £] Toggles between using Euro or Pound Sterling coin weights when determining the quantity and value of coins on the scale. An arrow in the Quantity window and a “E” or “S” in the denomination display indicates the selection. S ee section 2.4. [M+] Enters a new entry into memory. The memory will accumulate up to 99 entries. Tokens cannot be adde d to memory with coins. If nothing is in memory then to kens can be added but an error would be shown if both tokens and coins are added to memory. [MR] Recalls the separate entries from memory. [Total / ] Recalls the total value stored in memory [MC / ] Clears the memory. If [MR] has been used to recall the individual samples stored, then [MC] can be used to clear them from memory. [MC] will erase the complete contents of the memory only when the total is displayed (irr espective of whether [Total / ] or [MR] is pressed when the final total is displayed). [Print] Print and display a complete record of all data st ored in memory. [CE/ Esc] Resumes normal operation.