Page 81
ACU-RITE MILLPWRG2 81 5.1 Programming Introduction Program screen display When programming a machining step, the display changes according to the machining step selected. Once a machining step has been selected using the Program Steps soft key, the display will appear as shown here. The program steps display windows are described in the following table. 1Current program steps. 2Dialogue for a new milling step (e.g. Circle Pocket) 3Dialogue field graphic assistant. Graphic changes per input field...
Page 82
825 Program Overview 5.1 Programming Introduction Program mode soft keys When the DRO/PGM key is selected from DRO mode, the MILLPWRG2 screen changes to PGM mode, and the program default screen is displayed. When the MILLPWRG2 is set to program mode, types of milling functions specific to the hard key selected become available as soft keys. KeysFunction Program Functions opens additional soft keys to Load, Save, Clear, or Copy a program along with several other functions listed on the following...
Page 83
ACU-RITE MILLPWRG2 83 5.1 Programming Introduction Program functions Program functions soft keys The Program Functions soft key provides access to the following soft keys for saving, clearing, or loading an existing program to either edit or run. Soft keyFunction The Load soft key will load the selected program. If a program is currently loaded, a prompt will be displayed asking for confirmation to clear the loaded program. If a program is currently loaded, it must be saved prior to pressing this...
Page 84
845 Program Overview 5.1 Programming Introduction Pressing the Select soft key feature opens a popup menu that provides these three choices: The Select feature will select one or more programs. Highlight each program to be selected, and choose Select for each program highlighted. The Select All feature will select all programs in the folder. The Clear feature will un-select one or more programs that have been highlighted. Clear does not delete a program, it will only un-select it. Having a...
Page 85
ACU-RITE MILLPWRG2 85 5.1 Programming Introduction Choosing the Delete feature will delete one or more programs selected. The message bar will be displayed showing the first selected program asking for confirmation to delete it. Four soft keys are displayed for deleting options. Yes will delete the current program displayed in the message bar. Cancel will cancel out of the current operation. Cancel will not restore any prior deletions that had been made. All will delete all the selected programs...
Page 86
865 Program Overview 5.1 Programming Introduction View hard key Once a program is opened, first select how the part should be displayed in the graphics window. Pressing the VIEW key opens the display dialogue for View Setup to set the viewing graphic options of the program. Pressing the View key again, or pressing the CANCEL key will turn the VIEW key display off. See Program drawing view on page 80”. All drop down menus are accessed by pressing the RIGHT ARROW key to open the menu. Selection is...
Page 87
ACU-RITE MILLPWRG2 87 5.1 Programming Introduction FeaturesFeatures can be turned on and off and are graphical representations of the following: Tool Path is the path the tool will take as it moves to cut the part. Rapids are the tool movements that are set at a rapid feed rate. Contour is the geometry of the programmed contour. M arkers are the zero point marker, reference point markers, drill marker cross-hairs, and lines of reflection. Display Grid Display Grid is available when viewing...
Page 88
885 Program Overview 5.1 Programming Introduction Step functions soft keys The Step Functions soft key provides access to the following soft keys for assistance with programing steps, and modifying or arranging the programs steps. Soft keyFunction The Explode soft key will explode a program step e.g. such as a bolt circle converting it from a radius and number of holes equally spaced to individual coordinates for each hole. See Explode on page 190 for additional information. The Reverse Step soft...
Page 89
ACU-RITE MILLPWRG2 89 5.1 Programming Introduction Program steps soft keys The Program Steps soft key accesses the soft keys listed in the table below. Each soft key (except for the Tool key) provides additional selections on a popup menu. This allows to further define the milling action to be programmed. Soft keyFunction The Tool soft key opens a tool dialogue to enter the size and type of tool to be used for the following step(s). The Position/Milling soft key opens a popup menu to further define...
Page 90
905 Program Overview 5.1 Programming Introduction Clear program soft key This soft key provides a quick method to clear the current loaded program. It does not provide an option to save before exiting. Its function is meant to quickly clear a program (e.g. once it has been run and is no longer needed), so that a new program can be loaded, or a blank program is available, or return to DRO mode without having a program loaded. If the program has been edited the operator is asked to confirm the Clear...