    Error Message List
    No beep Error MessagesFRU/Action in Sequence
    No beep, power-on indicator turns off and LCD is 
    blank.Power source (battery pack and power adapter). See “Power 
    System Check” on page 67. 
    Ensure every connector is connected tightly and correctly. 
    Reconnect the DIMM.
    LED board.
    System board.
    No beep, power-on indicator turns on and LCD is 
    blank.Power source (battery pack and power adapter). See “Power 
    System Check” on page 67. 
    Reconnect the LCD connector
    Hard disk drive
    LCD inverter ID
    LCD cable
    LCD Inverter
    LCD
    System board
    No beep, power-on indicator turns on and LCD is 
    blank. But you can see POST on an external 
    CRT. Reconnect the LCD connectors.
    LCD inverter ID
    LCD cable 
    LCD inverter
    LCD
    System board
    No beep, power-on indicator turns on and a 
    blinking cursor shown on LCD during POST.Ensure every connector is connected tightly and correctly.
    System board
    No beep during POST but system runs correctly. Speaker
    System board
    Error Beep List
    CodeBeepsDescription
    00h Two long beeps, one short beep, and then one long beep Success
    F1h One long, One short beeps BIOS file size mismatch
    F2h One long, two short beeps BIOS file reading error
    D1h Two short beeps Floppy drive not installed 
    						
    							74Chapter 4
    Index of Symptom-to-FRU Error Message
    LCD-Related Symptoms
    Symptom / ErrorAction in Sequence
    LCD backlight doesnt work
    LCD is too dark
    LCD brightness cannot be adjusted
    LCD contrast cannot be adjustedEnter BIOS Utility to execute “Load Setup Default Settings”, then 
    reboot system.
    Reconnect the LCD connectors.
    Keyboard (if contrast and brightness function key doesnt work).
    LCD inverter ID
    LCD cable
    LCD inverter
    LCD
    System board
    Unreadable LCD screen 
    Missing pels in characters
    Abnormal screen 
    Wrong color displayedReconnect the LCD connector
    LCD inverter ID
    LCD cable
    LCD inverter
    LCD
    System board
    LCD has extra horizontal or vertical lines 
    displayed.LCD inverter ID
    LCD inverter
    LCD cable
    LCD
    System board
    Indicator-Related Symptoms
    Symptom / ErrorAction in Sequence
    Indicator incorrectly remains off or on, but system 
    runs correctlyReconnect the inverter board
    Inverter board
    System board
    Power-Related Symptoms
    Symptom / ErrorAction in Sequence
    Power shuts down during operation Power source (battery pack and power adapter). See “Power 
    System Check” on page 67. 
    Battery pack
    Power adapter
    Hard drive & battery connection board
    System board
    The system doesn’t power-on. Power source (battery pack and power adapter). See “Power 
    System Check” on page 67. 
    Battery pack
    Power adapter
    Hard drive & battery connection board
    System board
    The system doesn’t power-off. Power source (battery pack and power adapter). See “Power 
    System Check” on page 67. 
    Hold and press the power switch for more than 4 seconds.  
    System board
    Battery can’t be charged See “Check the Battery Pack” on page 69. 
    Battery pack
    System board 
    						
    							Chapter 475
    PCMCIA-Related Symptoms
    Symptom / ErrorAction in Sequence
    System cannot detect the PC Card (PCMCIA)  PCMCIA slot assembly
    System board
    PCMCIA slot pin is damaged. PCMCIA slot assembly
    Memory-Related Symptoms
    Symptom / ErrorAction in Sequence
    Memory count (size) appears different from 
    actual size.Enter BIOS Setup Utility to execute “Load Default Settings, then 
    reboot system.
    DIMM
    System board
    Speaker-Related Symptoms
    Symptom / ErrorAction in Sequence
    In Windows, multimedia programs, no sound 
    comes from the computer. Audio driver
    Speaker
    System board
    Internal speakers make noise or emit no sound. Speaker
    System board
    Power Management-Related Symptoms
    Symptom / ErrorAction in Sequence
    The system will not enter hibernation Keyboard (if control is from the keyboard)
    Hard disk drive
    System board
    The system doesnt enter hibernation mode and 
    four short beeps every minute.See “Hibernation Mode” on page 28.
    Press Fn+F4 and see if the computer enters hibernation mode.
    Touchpad
    Keyboard
    Hard disk connection board
    Hard disk drive
    System board
    The system doesn’t enter standby mode after 
    closing the LCDSee “Hibernation Mode” on page 28.
    LCD cover switch
    System board
    The system doesnt resume from hibernation 
    mode.See “Hibernation Mode” on page 28.
    Hard disk connection board
    Hard disk drive
    System board
    The system doesnt resume from standby mode 
    after opening the LCD.See “Standby Mode” on page 27.
    LCD cover switch
    System board
    Battery fuel gauge in Windows doesn’t go higher 
    than 90%. Remove battery pack and let it cool for 2 hours.
    Refresh battery (continue use battery until power off, then charge 
    battery).
    Battery pack
    System board 
    						
    							76Chapter 4
    NOTE: If you cannot find a symptom or an error in this list and the problem remains, see “Undetermined 
    Problems” on page 78.
    System hangs intermittently. See “Thermal Utility” on page 40. 
    Reconnect hard disk/CD-ROM drives. 
    Hard disk connection board
    System board
    Peripheral-Related Symptoms
    Symptom / ErrorAction in Sequence
    System configuration does not match the 
    installed devices. Enter BIOS Setup Utility to execute “Load Default Settings”, then 
    reboot system.
    Reconnect hard disk/CD-ROM/diskette drives.
    External display does not work correctly. Press Fn+F5, LCD/CRT/Both display switching
    See “System Diagnostic Diskette” on page 40. 
    System board
    USB does not work correctly See “System Diagnostic Diskette” on page 40
    System board
    Print problems. Ensure the “Parallel Port” in the “Onboard Devices Configuration” of 
    BIOS Setup Utility is set to Enabled.
    Onboard Devices Configuration
    Run printer self-test.
    Printer driver
    Printer cable
    Printer
    System Board
    Serial or parallel port device problems. Ensure the “Serial Port” in the Devices Configuration” of BIOS Setup 
    Utility is set to Enabled.
    Device driver
    Device cable
    Device
    System board
    Keyboard/Touchpad-Related Symptoms
    Symptom / ErrorAction in Sequence
    Keyboard (one or more keys) does not work. Reconnect the keyboard cable.
    Keyboard
    System board
    Touchpad does not work. Reconnect touchpad cable.
    Touchpad board
    System board
    Modem-Related Symptoms
    Symptom / ErrorAction in Sequence
    Internal modem does not work correctly. See “System Diagnostic Diskette” on page 40.
    Modem phone port
    modem combo board
    System board
    Power Management-Related Symptoms
    Symptom / ErrorAction in Sequence 
    						
    							Chapter 477
    Intermittent Problems
    Intermittent system hang problems can be caused by a variety of reasons that have nothing to do with a 
    hardware defect, such as: cosmic radiation, electrostatic discharge, or software errors. FRU replacement 
    should be considered only when a recurring problem exists.
    When analyzing an intermittent problem, do the following:
    1.Run the advanced diagnostic test for the system board in loop mode at least 10 times.
    2.If no error is detected, do not replace any FRU.
    3.If any error is detected, replace the FRU. Rerun the test to verify that there are no more errors.  
    						
    							78Chapter 4
    Undetermined Problems
    The diagnostic problems does not identify which adapter or device failed, which installed devices are incorrect, 
    whether a short circuit is suspected, or whether the system is inoperative.  
    Follow these procedures to isolate the failing FRU (do not isolate non-defective FRU).
    NOTE: Verify that all attached devices are supported by the computer.
    NOTE: Verify that the power supply being used at the time of the failure is operating correctly. (See “Power 
    System Check” on page 67):
    1.Power-off the computer.
    2.Visually check them for damage. If any problems are found, replace the FRU.
    3.Remove or disconnect all of the following devices:
    TNon-Acer devices
    TPrinter, mouse, and other external devices
    TBattery pack
    THard disk drive
    TDIMM 
    TCD-ROM/Diskette drive Module
    TPC Cards
    4.Power-on the computer.
    5.Determine if the problem has changed.
    6.If the problem does not recur, reconnect the removed devices one at a time until you find the failing FRU.
    7.If the problem remains, replace the following FRU one at a time. Do not replace a non-defective FRU:
    TSystem board
    TLCD assembly 
    						
    							Chapter 479
    Index of AFlash BIOS Error Message
    Error MessageAction in Sequence
    Hardware Error  See “System Diagnostic Diskette” on page 40
    VPD Checksum Error Reboot the system and then retest with this diskette.
    BIOS Update Program Error Turn off the power and restart the system.
    System Error Make sure this AFlash BIOS diskette for this model.
    Without AC adapter make sure to connect AC adapter
    Battery Low make sure to install a highly charged battery, and reboot 
    system. 
    						
    							80Chapter 4
    Index of PQA Diagnostic Error Code, Message
    Error CodeMessageAction in Sequence
    16XXX Backup battery error Backup battery
    01XXX CPU or main board error Reload BIOS default setting.
    System board
    02XXX Memory error DIMM
    System board
    03XXX Keyboard error Reset Keyboard
    Keyboard
    System board
    04XXX Video error System board
    05XXX Parallel Port error System board
    06XXX Serial port or main board error System board
    07XXX Diskette drive error Diskette drive
    System board
    08XXX Hard disk error Reload BIOS default setting
    Hard disk
    System board
    09XXX CD-ROM error Reset CD-ROM cable
    CD-ROM drive
    System board
    10XXX Co-processor error System board
    11XXX Pointing device error Reset Keyboard
    Keyboard
    System board
    12XXX Cache test error System board 
    						
    							Chapter 581
    To p  Vi e w
    PCB 01201-SD
    SW1 Power switch CN9 Line-in port
    CN3 LCD cover switch connector CN12 Line-out port
    JK1 AC adapter connector DM1 Memory slot 1
    JK2 RJ11 and RJ45 connectors SW2 Please refer to below for SW settings
    CN2 LCD coaxial cable connector CN8 RTC battery connector
    CN4 LED/Inverter board connector CN14 Internal microphone and tablet PC lid 
    connector
    CN6 Fax/Modem board connector CN13 PCMCIA card connector
    CN1 VGA port CN7 Keyboard cable connector
    SKT1 USB port 1 CN11 Battery connector
    SKT2 USB port 2 CN10 Touchpad connector
    SK1 1394 port CN5 Hard disk drive connector
    SW1CN3
    JK1CN2CN4
    CN6 CN1
    SKT1
    SKT2
    SK1
    CN9
    CN12
    DM1
    SW2
    CN8
    CN14 CN13 CN7 CN11 CN10 CN5JK2
    Jumper and Connector Locations
    Chapter 5 
    						
    							82Chapter 5
    SW2 Settings
    NOTE: *:  Default setting
    SW4Setting
    Switch 1 ON:    Disable password check
    OFF*:  Enable password check
    Switch 2 ON:    Enable BootBlock Erasable
    OFF*:  Disable BootBlock Erasable 
    						