    							Chapter 473
    PCMCIA-Related Symptoms
    Symptom / ErrorAction in Sequence
    System cannot detect the PC Card (PCMCIA)  See “System Diagnostic Diskette” on page 45. Please run Sycard 32 
    Bit test.
    PCMCIA slot assembly
    Main board
    PCMCIA slot pin is damaged. PCMCIA slot assembly
    Memory-Related Symptoms
    Symptom / ErrorAction in Sequence
    Memory count (size) appears different from 
    actual size.DIMM
    Main board
    Speaker-Related Symptoms
    Symptom / ErrorAction in Sequence
    In Windows, multimedia programs, no sound 
    comes from the computer. See “Sound Check” on page 68
    Audio driver
    Speaker
    Main board
    Internal speakers make noise or emit no sound. See “Sound Check” on page 68
    Speaker
    Main board
    Power Management-Related Symptoms
    Symptom / ErrorAction in Sequence
    The system will not enter hibernation Keyboard (if control is from the keyboard)
    Hard disk drive
    Main board
    The system doesnt enter hibernation mode and 
    four short beeps every minute.Press Fn+F4 and see if the computer enters hibernation mode.
    Touchpad
    Keyboard
    Hard disk connection board
    Hard disk drive
    Main board
    The system doesn’t enter standby mode after 
    closing the LCDLCD cover switch
    Main board
    The system doesnt resume from hibernation 
    mode.Hard disk connection board
    Hard disk drive
    Main board
    The system doesnt resume from standby mode 
    after opening the LCD.LCD cover switch
    Main board
    Battery fuel gauge in Windows doesn’t go higher 
    than 90%. Remove battery pack and let it cool for 2 hours.
    Refresh battery (continue use battery until power off, then charge 
    battery).
    Battery pack
    Main board
    System hangs intermittently. Reconnect hard disk drives. 
    Hard disk drive connector
    Main board
    SG_TM800.book  Page 73  Thursday, February 27, 2003  10:21 PM 
    						
    							74Chapter 4
    NOTE: If you cannot find a symptom or an error in this list and the problem remains, see “Undetermined 
    Problems” on page 76. Peripheral-Related Symptoms
    Symptom / ErrorAction in Sequence
    System configuration does not match the 
    installed devices. Enter BIOS Setup Utility to execute “Load Setup defaults”, then 
    reboot system.
    Reconnect hard disk/CD-ROM/diskette drives.
    External display does not work correctly. See “System Diagnostic Diskette” on page 45
    See if there is an error beep. If there is an erro beep, then change 
    main board.
    Power off. Then check if RAM CPU BIOS are well-connected.
    Press Fn+F5 three times slowly
    LCD FPC
    LCD inverter
    LCD
    USB does not work correctly USB device cable is firmly connected into the USB ports. Test one 
    USB port each time.
    USB socket is firmly secured to the main board.
    Main board
    Print problems. Ensure the “Parallel Port” in the “System Devices” of BIOS Setup 
    Utility is set to Enabled.
    Onboard Devices Configuration
    Run parallel port test
    Printer driver
    Printer cable
    Printer
    Main board
    Keyboard/Touchpad-Related Symptoms
    Symptom / ErrorAction in Sequence
    Keyboard (one or more keys) does not work. Reconnect the keyboard cable.
    Keyboard
    Main board
    Touchpad does not work. Reconnect touch pad cable. Modem port is secured to the main 
    board
    Touch pad FPC
    Audio/Touch pad board
    Main board
    Modem-Related Symptoms
    Symptom / ErrorAction in Sequence
    Internal modem does not work correctly. Ensure the telephone cable is firmly plugged into the telephone wall 
    socket and the modem port of the computer.
    Modem phone port is secured to the main board.
    modem combo board
    Main board
    SG_TM800.book  Page 74  Thursday, February 27, 2003  10:21 PM 
    						
    							Chapter 475
    Intermittent Problems
    Intermittent system hang problems can be caused by a variety of reasons that have nothing to do with a 
    hardware defect, such as: cosmic radiation, electrostatic discharge, or software errors. FRU replacement 
    should be considered only when a recurring problem exists.
    When analyzing an intermittent problem, do the following:
    1.Run the diagnostic test for several times to isolate the problem.
    2.If no error is detected, do not replace any FRU.
    3.If any error is detected, replace the FRU.  Rerun the test to verify that there are no more errors.
    If an error is detected by the main battery test, see “Check the Power Adapter” on page 66
    If an error is detected by the display test, see “Index of Symptom-to-FRU Error Message” on page 
    72 .
    If an error is detected by the floppy disk drive test, see “External Diskette Drive Check” on page 64.
    If an error is detected by the keyboard test, see “Keyboard or Auxiliary Input Device Check” on 
    page 65.
    SG_TM800.book  Page 75  Thursday, February 27, 2003  10:21 PM 
    						
    							76Chapter 4
    Undetermined Problems
    The diagnostic problems does not identify which adapter or device failed, which installed devices are incorrect, 
    whether a short circuit is suspected, or whether the system is inoperative.  
    Follow these procedures to isolate the failing FRU (do not isolate non-defective FRU).
    NOTE: Verify that all attached devices are supported by the computer.
    NOTE: Verify that the power supply being used at the time of the failure is operating correctly. (See “Power 
    System Check” on page 65):
    1.Power-off the computer.
    2.Visually check them for damage. If any problems are found, replace the FRU.
    3.Remove or disconnect all of the following devices:
    •Non-Acer devices
    •Printer, mouse, and other external devices
    •Battery pack
    •Hard disk drive
    •DIMM 
    •CD-ROM/Diskette drive Module
    •PC Cards
    4.Power-on the computer.
    5.Determine if the problem has changed.
    6.If the problem does not recur, reconnect the removed devices one at a time until you find the failing FRU.
    7.If the problem remains, replace the following FRU one at a time. Do not replace a non-defective FRU:
    •Main board
    •LCD assembly
    SG_TM800.book  Page 76  Thursday, February 27, 2003  10:21 PM 
    						
    							Chapter 477
    Index of AFlash BIOS Error Message
    Error MessageAction in Sequence
    Hardware Error  See “System Diagnostic Diskette” on page 45
    VPD Checksum Error Reboot the system and then restest with this diskette.
    BIOS Update Program Error Turn off the power and restart the system.
    System Error Make sure this AFlash BIOS diskette for this model.
    Without AC adapter make sure to connect AC adapter
    Battery Low make sure to install a highly charged battery, and reboot 
    system.
    SG_TM800.book  Page 77  Thursday, February 27, 2003  10:21 PM 
    						
    							78Chapter 4
    SG_TM800.book  Page 78  Thursday, February 27, 2003  10:21 PM 
    						
    							Chapter 579
    This chapter gives you the FRU (Field Replaceable Unit) listing in global configurations of TravelMate 800
    series products. Refer to this chapter whenever ordering for parts to repair or for RMA (Return Merchandise
    Authorization).
    Please note that WHEN ORDERING FRU PARTS, you should check the most up-to-date information available
    on your regional web or channel. For whatever reasons a part number change is made, it will not be noted on
    the printed Service Guide.  For ACER AUTHORIZED SERVICE PROVIDERS, your Acer office may have a
    DIFFERENT part number code from those given in the FRU list of this printed Service Guide. You MUST use
    the local FRU list provided by your regional Acer office to order FRU parts for repair and service of customer
    machines.
    NOTE: To scrap or to return the defective parts, you should follow the local government ordinance or
    regulations on how to dispose it properly, or follow the rules set by your regional Acer office on how to
    return it.
    FRU (Field Replaceable Unit) List
    Chapter 5
    SG_TM800.book  Page 79  Thursday, February 27, 2003  10:21 PM 
    						
    							80Chapter 5
    Exploded Diagram
    THE SYSTEM
    SG_TM800.book  Page 80  Thursday, February 27, 2003  10:21 PM 
    						
    							Chapter 581
    LCD
    SG_TM800.book  Page 81  Thursday, February 27, 2003  10:21 PM 
    						
    							82Chapter 5
    DVD ASSY
    NOTE: The exploded diagrams for CD-ROM, DVD-ROM and DVD-RW combo module are very similar. 
    Therefor, we put only DVD ASSY exploded diagram for your reference. Please also refer to the FRU list 
    below for more information on different models and part numbers. This diagram only explains the 
    relevant location of each part. The parts on the exploded diagrams may be a slightly different from its 
    actual looks.