Chapter 483 Error Message List No beep Error MessagesFRU/Action in Sequence No beep, power-on indicator turns off and LCD is blank.Power source (battery pack and power adapter). See “Power System Check” on page 77. Ensure every connector is connected tightly and correctly. Reconnect the DIMM. LED board. System board. No beep, power-on indicator turns on and LCD is blank.Power source (battery pack and power adapter). See “Power System Check” on page 77. Reconnect the LCD connector Hard disk drive LCD inverter ID LCD cable LCD Inverter LCD System board No beep, power-on indicator turns on and LCD is blank. But you can see POST on an external CRT. Reconnect the LCD connectors LCD inverter ID LCD cable LCD inverter LCD System board No beep, power-on indicator turns on and a blinking cursor shown on LCD during POST.Ensure every connector is connected tightly and correctly System board No beep during POST but system runs correctly. Speaker System board
84Chapter 4 POST Code CodeBeepsFor Boot Block in Flash ROM E0h Initialize the chipset E1h Initialize the bridge E2h Initialize the CPU E3h Initialize the system timer E4h Initialize system I/O E5h Check force recovery boot E6h Checksum BIOS ROM E7h Go to BIOS E8h Set Huge Segment E9h Initialize Multi Processor EAh Initialize OEM special code EBh Initialize PIC and DMA ECh Initialize Memory type EDh Initialize Memory size EEh Shadow Boot Block EFh System memory test F0h Initialize interrupt vectors F1h Initialize Run Time Clock F2h Initialize video F3h Initialize System Management Mode F4h 1 Output one beep before boot F5h Boot to Mini DOS F6h Clear Huge Segment F7h Boot to Full DOS
Chapter 485 Index of Symptom-to-FRU Error Message LCD-Related Symptoms Symptom / ErrorAction in Sequence LCD backlight doesnt work LCD is too dark LCD brightness cannot be adjusted LCD contrast cannot be adjustedEnter BIOS Utility to execute “Load Setup Default Settings”, then reboot system. Reconnect the LCD connectors. Keyboard (if contrast and brightness function key doesnt work). LCD inverter ID LCD cable LCD inverter LCD System board Unreadable LCD screen Missing pels in characters Abnormal screen Wrong color displayedReconnect the LCD connector LCD inverter ID LCD cable LCD inverter LCD System board LCD has extra horizontal or vertical lines displayed.LCD inverter ID LCD inverter LCD cable LCD System board Indicator-Related Symptoms Symptom / ErrorAction in Sequence Indicator incorrectly remains off or on, but system runs correctlyReconnect the inverter board Inverter board System board Power-Related Symptoms Symptom / ErrorAction in Sequence Power shuts down during operation Power source (battery pack and power adapter). See “Power System Check” on page 77. Battery pack Power adapter Hard drive & battery connection board System board The system doesn’t power-on. Power source (battery pack and power adapter). See “Power System Check” on page 77. Battery pack Power adapter Hard drive & battery connection board System board The system doesn’t power-off. Power source (battery pack and power adapter). See “Power System Check” on page 77. Hold and press the power switch for more than 4 seconds. System board Battery can’t be charged See “Check the Battery Pack” on page 79. Battery pack System board
86Chapter 4 PCMCIA-Related Symptoms Symptom / ErrorAction in Sequence System cannot detect the PC Card (PCMCIA) PCMCIA slot assembly System board PCMCIA slot pin is damaged. PCMCIA slot assembly Memory-Related Symptoms Symptom / ErrorAction in Sequence Memory count (size) appears different from actual size.Enter BIOS Setup Utility to execute “Load Default Settings, then reboot system. DIMM System board Speaker-Related Symptoms Symptom / ErrorAction in Sequence In Windows, multimedia programs, no sound comes from the computer. Audio driver Speaker System board Internal speakers make noise or emit no sound. Speaker System board Power Management-Related Symptoms Symptom / ErrorAction in Sequence The system will not enter hibernation Keyboard (if control is from the keyboard) Hard disk drive System board The system doesnt enter hibernation mode and four short beeps every minute.See “Hibernation Mode” on page 34. Press Fn+ oand see if the computer enters hibernation mode. Touchpad Keyboard Hard disk connection board Hard disk drive System board The system doesn’t enter standby mode after closing the LCDSee “Hibernation Mode” on page 34. LCD cover switch System board The system doesnt resume from hibernation mode.See “Hibernation Mode” on page 34. Hard disk connection board Hard disk drive System board The system doesnt resume from standby mode after opening the LCD.See “Hibernation Mode” on page 34. LCD cover switch System board Battery fuel gauge in Windows doesn’t go higher than 90%. Remove battery pack and let it cool for 2 hours Refresh battery (continue use battery until power off, then charge battery) Battery pack System board
Chapter 487 NOTE: If you cannot find a symptom or an error in this list and the problem remains, see “Undetermined Problems” on page 89. System hangs intermittently. Reconnect hard disk/CD-ROM drives. Hard disk connection board System board Peripheral-Related Symptoms Symptom / ErrorAction in Sequence System configuration does not match the installed devices. Enter BIOS Setup Utility to execute “Load Default Settings”, then reboot system. Reconnect hard disk/CD-ROM/diskette drives. External display does not work correctly. Press Fn+F5, LCD/CRT/Both display switching System board USB does not work correctly System board Print problems. Ensure the “Parallel Port” in the “Onboard Devices Configuration” of BIOS Setup Utility is set to Enabled. Onboard Devices Configuration Run printer self-test. Printer driver Printer cable Printer System Board Serial or parallel port device problems. Ensure the “Serial Port” in the Devices Configuration” of BIOS Setup Utility is set to Enabled. Device driver Device cable Device System board Keyboard/Touchpad-Related Symptoms Symptom / ErrorAction in Sequence Keyboard (one or more keys) does not work. Reconnect the keyboard cable. Keyboard System board Touchpad does not work. Reconnect touchpad cable. Touchpad board System board Modem-Related Symptoms Symptom / ErrorAction in Sequence Internal modem does not work correctly. Modem phone port modem combo board System board Power Management-Related Symptoms Symptom / ErrorAction in Sequence
88Chapter 4 Intermittent Problems Intermittent system hang problems can be caused by a variety of reasons that have nothing to do with a hardware defect, such as: cosmic radiation, electrostatic discharge, or software errors. FRU replacement should be considered only when a recurring problem exists. When analyzing an intermittent problem, do the following: 1.Run the advanced diagnostic test for the system board in loop mode at least 10 times. 2.If no error is detected, do not replace any FRU. 3.If any error is detected, replace the FRU. Rerun the test to verify that there are no more errors.
Chapter 489 Undetermined Problems The diagnostic problems does not identify which adapter or device failed, which installed devices are incorrect, whether a short circuit is suspected, or whether the system is inoperative. Follow these procedures to isolate the failing FRU (do not isolate non-defective FRU). NOTE: Verify that all attached devices are supported by the computer. NOTE: Verify that the power supply being used at the time of the failure is operating correctly. (See “Power System Check” on page 77): 1.Power-off the computer. 2.Visually check them for damage. If any problems are found, replace the FRU. 3.Remove or disconnect all of the following devices: !Non-Acer devices !Printer, mouse, and other external devices !Battery pack !Hard disk drive !DIMM !CD-ROM/Diskette drive Module !PC Cards 4.Power-on the computer. 5.Determine if the problem has changed. 6.If the problem does not recur, reconnect the removed devices one at a time until you find the failing FRU. 7.If the problem remains, replace the following FRU one at a time. Do not replace a non-defective FRU: !System board !LCD assembly
90Chapter 4 Use NAPP CD to Build Master Hard Disc Drive CD to Disk Recovery 1.Prepare NAPP CD, Recovery CD and System CD. 2.Put NAPP CD into the optical drive. Then boot up the system. 3.The system will ask you if you want to build NAPP Master HDD. Please press any key to continue. 4.NAPP CD will start to preload the system, please click [Y].
Chapter 491 5.Select CD to Disk Revocery. 6.Put the Recovery CD to the optical drive. This step is to create image files to the system, you do not have to put the Recovery CD to the optical drive in order. Place one Recovery CD to the drive at one time till you finish all Recovery CDs. After you place the Recovery CD to the optical drive, you will see the display below.
92Chapter 4 7.Then insert the System CD to the optical drive. 8.You will see the screen displaying “PASS” when the system has buit NAPP Master hard disc drive.