    							Chapter 4 91
    Extended RAM Failed at 
    offset: nnnnDIMM
    System board
    System battery is dead - 
    Replace and run SetupReplace RTC battery and Run BIOS Setup Utility 
    to reconfigure system time, then reboot system.
    System CMOS checksum 
    bad - Default configuration 
    usedRTC battery
    Run BIOS Setup Utility to reconfigure system 
    time, then reboot system.
    System timer error RTC battery
    Run BIOS Setup Utility to reconfigure system 
    time, then reboot system.
    System board
    Real time clock error RTC battery
    Run BIOS Setup Utility to reconfigure system 
    time, then reboot system.
    System board
    Previous boot incomplete - 
    Default configuration usedRun “Load Default Settings” in BIOS Setup Utility.
    RTC battery
    System board
    Memory size found by 
    POST differed from CMOSRun “Load Default Settings” in BIOS Setup Utility.
    DIMM
    System board
    Diskette drive A error Check the drive is defined with the proper diskette 
    type in BIOS Setup Utility
    See “External Diskette Drive Check” on page 86. 
    Incorrect Drive A type - run 
    SETUPCheck the drive is defined with the proper diskette 
    type in BIOS Setup Utility
    See “External Diskette Drive Check” on page 86. 
    System cache error - Cache 
    disabledSystem board
    CPU ID: System board
    DMA Test Failed DIMM
    System board
    Software NMI Failed DIMM
    System board
    Fail-Safe Timer NMI Failed DIMM
    System board
    Device Address Conflict Run “Load Default Settings” in BIOS Setup Utility.
    RTC battery
    System board
    Error Messages List
    Error MessagesAction in Sequence 
    						
    							92 Troubleshooting 
    Allocation Error for: device Run “Load Default Settings” in BIOS Setup Utility.
    RTC battery
    System board
    Failing Bits: nnnn DIMM
    BIOS ROM
    System board
    Fixed Disk n None
    Invalid System 
    Configuration DataBIOS ROM
    System board
    I/O device IRQ conflict Run “Load Default Settings” in BIOS Setup Utility.
    RTC battery
    System board
    Operating system not found Enter Setup and see if fixed disk and drive A: are 
    properly identified.
    Diskette drive
    Hard disk drive
    System board
    No-Beep Symptoms
    Symptom / ErrorAction in Sequence
    No beep, power-on 
    indicator turns off and LCD 
    is blank.Power source (battery pack and power adapter). 
    See “Power System Check” on page 88. 
    Ensure every connector is connected tightly and 
    correctly. 
    Reconnect the DIMM.
    LED board.
    System board.
    No beep, power-on 
    indicator turns on and LCD 
    is blank.Power source (battery pack and power adapter). 
    See “Power System Check” on page 88. 
    Reconnect the LCD connector
    Hard disk drive
    LCD inverter ID
    LCD cable
    LCD Inverter
    LCD
    System board
    Error Messages List
    Error MessagesAction in Sequence 
    						
    							Chapter 4 93
    No beep, power-on 
    indicator turns on and LCD 
    is blank.  But you can see 
    POST on an external CRT. Reconnect the LCD connectors.
    LCD inverter ID
    LCD  cable 
    LCD inverter
    LCD
    System board
    No beep, power-on 
    indicator turns on and a 
    blinking cursor shown on 
    LCD during POST.Ensure every connector is connected tightly and 
    correctly.
    System board
    No beep during POST but 
    system runs correctly.Speaker
    System board
    LCD-Related Symptoms
    Symptom / ErrorAction in Sequence
    LCD backlight doesnt work
    LCD is too dark
    LCD brightness cannot be 
    adjusted
    LCD contrast cannot be 
    adjustedEnter BIOS Utility to execute “Load Setup Default 
    Settings”, then reboot system.
    Reconnect the LCD connectors.
    Keyboard (if contrast and brightness function key 
    doesnt work).
    LCD inverter ID
    LCD cable
    LCD inverter
    LCD
    System board
    Unreadable LCD screen 
    Missing pels in characters
    Abnormal screen 
    Wrong color displayedReconnect the LCD connector
    LCD inverter ID
    LCD cable
    LCD inverter
    LCD
    System board
    LCD has extra horizontal or 
    vertical lines displayed.LCD inverter ID
    LCD inverter
    LCD cable
    LCD
    System board
    No-Beep Symptoms
    Symptom / ErrorAction in Sequence 
    						
    							94 Troubleshooting 
    Indicator-Related Symptoms
    Symptom / ErrorAction in Sequence
    Indicator incorrectly remains 
    off or on, but system runs 
    correctlyReconnect the inverter board
    Inverter board
    System board
    Power-Related Symptoms
    Symptom / ErrorAction in Sequence
    Power shuts down during 
    operationPower source (battery pack and power adapter). 
    See “Power System Check” on page 88. 
    Battery pack
    Power adapter
    Hard drive & battery connection board
    System board
    The system doesn’t power-
    on.Power source (battery pack and power adapter). 
    See “Power System Check” on page 88. 
    Battery pack
    Power adapter
    Hard drive & battery connection board
    System board
    The system doesn’t power-
    off.Power source (battery pack and power adapter). 
    See “Power System Check” on page 88. 
    Hold and press the power switch for more than 4 
    seconds.  
    System board
    Battery can’t be charged See “Check the Battery Pack” on page 88. 
    Battery pack
    System board
    PCMCIA-Related Symptoms
    Symptom / ErrorAction in Sequence
    System cannot detect the 
    PC Card (PCMCIA) PCMCIA slot assembly
    System board
    PCMCIA slot pin is 
    damaged.PCMCIA slot assembly 
    						
    							Chapter 4 95
    Memory-Related Symptoms
    Symptom / ErrorAction in Sequence
    Memory count (size) 
    appears different from 
    actual size.Enter BIOS Setup Utility to execute “Load Default 
    Settings, then reboot system.
    DIMM
    System board
    Speaker-Related Symptoms
    Symptom / ErrorAction in Sequence
    In Windows, multimedia 
    programs, no sound comes 
    from the computer. Audio driver
    Speaker
    System board
    Internal speakers make 
    noise or emit no sound.Speaker
    System board 
    						
    							96 Troubleshooting 
    Power Management-Related Symptoms
    Symptom / ErrorAction in Sequence
    The system will not enter 
    hibernationKeyboard (if control is from the keyboard)
    Hard disk drive
    System board
    The system doesnt enter 
    hibernation mode and four 
    short beeps every minute.See “Hibernation Mode” on page 39.
    Press Fn+F4 and see if the computer enters 
    hibernation mode.
    Touchpad
    Keyboard
    Hard disk connection board
    Hard disk drive
    System board
    The system doesn’t enter 
    standby mode after closing 
    the LCDSee “Standby Mode” on page 39.
    LCD cover switch
    System board
    The system doesnt resume 
    from hibernation mode.See “Hibernation Mode” on page 39.
    Hard disk connection board
    Hard disk drive
    System board
    The system doesnt resume 
    from standby mode after 
    opening the LCD.See “Standby Mode” on page 39.
    LCD cover switch
    System board
    Battery fuel gauge in 
    Windows doesn’t go higher 
    than 90%. Remove battery pack and let it cool for 2 hours.
    Refresh battery (continue use battery until power 
    off, then charge battery).
    Battery pack
    System board
    System hangs intermittently. See “Set Thermal Sensor Threshold” on page 58. 
    Reconnect hard disk/CD-ROM drives. 
    Hard disk connection board
    System board 
    						
    							Chapter 4 97
    Peripheral-Related Symptoms
    Symptom / ErrorAction in Sequence
    System configuration does 
    not match the installed 
    devices. Enter BIOS Setup Utility to execute “Load Default 
    Settings”, then reboot system.
    Reconnect hard disk/CD-ROM/diskette drives.
    External display does not 
    work correctly.Press Fn+F5, LCD/CRT/Both display switching
    See “Running PQA Diagnostics Program.” on 
    page 60. 
    System board
    USB does not work 
    correctlySee “System Diagnostic Diskette” on page 59
    System board
    Print problems. Ensure the “Parallel Port” in the “Onboard 
    Devices Configuration” of BIOS Setup Utility is set 
    to Enabled.
    Onboard Devices Configuration
    Run printer self-test.
    Printer driver
    Printer cable
    Printer
    System Board
    Serial or parallel port device 
    problems.Ensure the “Serial Port” in the Devices 
    Configuration” of BIOS Setup Utility is set to 
    Enabled.
    Device driver
    Device cable
    Device
    System board
    Keyboard/Touchpad-Related Symptoms
    Symptom / ErrorAction in Sequence
    Keyboard (one or more 
    keys) does not work.Reconnect the keyboard cable.
    Keyboard
    System board
    Touchpad does not work. Reconnect touchpad cable.
    Touchpad board
    System board 
    						
    							98 Troubleshooting 
    Note: If you cannot find a symptom or an error in this list and the 
    problem remains, see “Undetermined Problems” on page 56.
    Intermittent Problems
    Intermittent system hang problems can be caused by a variety of reasons 
    that have nothing to do with a hardware defect, such as: cosmic radiation, 
    electrostatic discharge, or software errors. FRU replacement should be 
    considered only when a recurring problem exists.
    When analyzing an intermittent problem, do the following:
    1.  Run the advanced diagnostic test for the system board in loop mode at 
    least 10 times.
    2.  If no error is detected, do not replace any FRU.
    3.  If any error is detected, replace the FRU.  Rerun the test to verify that 
    there are no more errors. 
    Undetermined Problems
    The diagnostic problems does not identify which adapter or device failed, 
    which installed devices are incorrect, whether a short circuit is suspected, or 
    whether the system is inoperative.  
    Follow these procedures to isolate the failing FRU (do not isolate non-
    defective FRU).
    Note: Verify that all attached devices are supported by the computer.
    Note: Verify that the power supply being used at the time of the failure is 
    operating correctly. (See “Power System Check” on page 88):
    1.  Power-off the computer.
    2.  Visually check them for damage. If any problems are found, replace the 
    FRU . Modem-Related Symptoms
    Symptom / ErrorAction in Sequence
    Internal modem does not 
    work correctly.See “System Diagnostic Diskette” on page 59.
    Modem phone jack
    Modem board
    System board 
    						
    							Chapter 4 99
    3.  Remove or disconnect all of the following devices:
    Non-Acer devices
    Printer, mouse, and other external devices
    Battery pack
    Hard disk drive
    DIMM 
    CD-ROM/Diskette drive Module
    PC Cards
    4.  Power-on the computer.
    5.  Determine if the problem has changed.
    6.  If the problem does not recur, reconnect the removed devices one at a 
    time until you find the failing FRU.
    7.  If the problem remains, replace the following FRU one at a time. Do not 
    replace a non-defective FRU:
    System board
    LCD assembly 
    						