    							Chapter 4121
    B9h Prepare Boot
    BAh Initialize DMI parameters
    BBh Initialize PnP Option ROMs
    BCh Clear parity checkers
    BDh Display MultiBoot menu
    BEh Clear screen (optional)
    BFh Check virus and backup reminders
    C0h Try to boot with INT 19
    C1h Initialize POST Error Manager (PEM)
    C2h Initialize error logging
    C3h Initialize error display function
    C4h Initialize system error handler
    C5h PnPnd dual CMOS (optional)
    C6h Initialize notebook docking (optional)
    C7h Initialize notebook docking late
    C8h Force check (optional)
    C9h Extended checksum (optional)
    D2h Unknown interrupt
    CodeBeeps
    E0h Initialize the chipset
    E1h Initialize the bridge
    E2h Initialize the CPU
    E3h Initialize the system timer
    E4h Initialize system I/O
    E5h Check force recovery boot
    E6h Checksum BIOS ROM
    E7h Go to BIOS
    E8h Set Huge Segment
    E9h Initialize Multi Processor
    EAh Initialize OEM special code
    EBh Initialize PIC and DMA
    ECh Initialize Memory type
    EDh Initialize Memory size
    EEh Shadow Boot Block
    EFh System memory test
    F0h Initialize interrupt vectors
    F1h Initialize Run Time Clock
    F2h Initialize video
    F3h Initialize System Management Mode
    F4h 1 Output one beep before boot
    CodeBeepsPOST Routine Description 
    						
    							122Chapter 4
    F5h Boot to Mini DOS
    F6h Clear Huge Segment
    F7h Boot to Full DOS
    CodeBeeps 
    						
    							Chapter 4123
    Index of Symptom-to-FRU Error Message
    LCD-Related Symptoms
    Symptom / ErrorAction in Sequence
    LCD backlight doesnt work
    LCD is too dark
    LCD brightness cannot be adjusted
    LCD contrast cannot be adjustedEnter BIOS Utility to execute “Load Setup Default Settings”, 
    then reboot system.
    Reconnect the LCD connectors.
    Keyboard (if contrast and brightness function key doesnt 
    work).
    LCD inverter ID
    LCD cable
    LCD inverter
    LCD
    System board
    Unreadable LCD screen 
    Missing pels in characters
    Abnormal screen 
    Wrong color displayedReconnect the LCD connector
    LCD inverter ID
    LCD cable
    LCD inverter
    LCD
    System board
    LCD has extra horizontal or vertical lines 
    displayed.LCD inverter ID
    LCD inverter
    LCD cable
    LCD
    System board
    Indicator-Related Symptoms
    Symptom / ErrorAction in Sequence
    Indicator incorrectly remains off or on, but 
    system runs correctlyReconnect the inverter board
    Inverter board
    System board
    Power-Related Symptoms
    Symptom / ErrorAction in Sequence
    Power shuts down during operation Power source (battery pack and power adapter). See “Power 
    System Check” on page 111. 
    Battery pack
    Power adapter
    Hard drive & battery connection board
    System board
    The system doesn’t power-on. Power source (battery pack and power adapter). See “Power 
    System Check” on page 111. 
    Battery pack
    Power adapter
    Hard drive & battery connection board
    System board 
    						
    							124Chapter 4
    The system doesn’t power-off. Power source (battery pack and power adapter). See “Power 
    System Check” on page 111. 
    Hold and press the power switch for more than 4 seconds.  
    System board
    Battery can’t be charged See “Check the Battery Pack” on page 113. 
    Battery pack
    System board
    PCMCIA-Related Symptoms
    Symptom / ErrorAction in Sequence
    System cannot detect the PC Card 
    (PCMCIA) PCMCIA slot assembly
    System board
    PCMCIA slot pin is damaged. PCMCIA slot assembly
    Memory-Related Symptoms
    Symptom / ErrorAction in Sequence
    Memory count (size) appears different from 
    actual size.Enter BIOS Setup Utility to execute “Load Default Settings, 
    then reboot system.
    DIMM
    System board
    Speaker-Related Symptoms
    Symptom / ErrorAction in Sequence
    In Windows, multimedia programs, no 
    sound comes from the computer. Audio driver
    Speaker
    System board
    Internal speakers make noise or emit no 
    sound.Speaker
    System board
    Power Management-Related Symptoms
    Symptom / ErrorAction in Sequence
    The system will not enter hibernation See “Save to Disk (S4)” on page 41.
    Keyboard (if control is from the keyboard)
    Hard disk drive
    System board
    The system doesnt enter hibernation mode 
    and four short beeps every minute.Press Fn+
    oand see if the computer enters hibernation mode.
    Touchpad
    Keyboard
    Hard disk connection board
    Hard disk drive
    System board
    The system doesn’t enter standby mode 
    after closing the LCDSee “Save to Disk (S4)” on page 41.
    LCD cover switch
    System board Power-Related Symptoms
    Symptom / ErrorAction in Sequence 
    						
    							Chapter 4125
    The system doesnt resume from 
    hibernation mode.See “Save to Disk (S4)” on page 41.
    Hard disk connection board
    Hard disk drive
    System board
    The system doesnt resume from standby 
    mode after opening the LCD.See “Save to Disk (S4)” on page 41.
    LCD cover switch
    System board
    Battery fuel gauge in Windows doesn’t go 
    higher than 90%. Remove battery pack and let it cool for 2 hours.
    Refresh battery (continue use battery until power off, then 
    charge battery).
    Battery pack
    System board
    System hangs intermittently. Reconnect hard disk/CD-ROM drives. 
    Hard disk connection board
    System board
    Peripheral-Related Symptoms
    Symptom / ErrorAction in Sequence
    System configuration does not match the 
    installed devices. Enter BIOS Setup Utility to execute “Load Default Settings”, 
    then reboot system.
    Reconnect hard disk/CD-ROM/diskette drives.
    External display does not work correctly. Press Fn+F5, LCD/CRT/Both display switching
    System board
    USB does not work correctly System board
    Print problems. Ensure the “Parallel Port” in the “Onboard Devices 
    Configuration” of BIOS Setup Utility is set to Enabled.
    Onboard Devices Configuration
    Run printer self-test.
    Printer driver
    Printer cable
    Printer
    System Board
    Serial or parallel port device problems. Ensure the “Serial Port” in the Devices Configuration” of 
    BIOS Setup Utility is set to Enabled.
    Device driver
    Device cable
    Device
    System board
    Keyboard/Touchpad-Related Symptoms
    Symptom / ErrorAction in Sequence
    Keyboard (one or more keys) does not 
    work.Reconnect the keyboard cable.
    Keyboard
    System board Power Management-Related Symptoms
    Symptom / ErrorAction in Sequence 
    						
    							126Chapter 4
    NOTE: If you cannot find a symptom or an error in this list and the problem remains, see “Undetermined 
    Problems” on page 129. Touchpad does not work. Reconnect touchpad cable.
    Touchpad board
    System board
    Modem-Related Symptoms
    Symptom / ErrorAction in Sequence
    Internal modem does not work correctly. Modem phone port
    modem combo board
    System board Keyboard/Touchpad-Related Symptoms
    Symptom / ErrorAction in Sequence 
    						
    							Chapter 4127
    Intermittent Problems
    Intermittent system hang problems can be caused by a variety of reasons that have nothing to do with a 
    hardware defect, such as: cosmic radiation, electrostatic discharge, or software errors. FRU replacement 
    should be considered only when a recurring problem exists.
    When analyzing an intermittent problem, do the following:
    1.Run the advanced diagnostic test for the system board in loop mode at least 10 times.
    2.If no error is detected, do not replace any FRU.
    3.If any error is detected, replace the FRU. Rerun the test to verify that there are no more errors.  
    						
    							128Chapter 4
    Undetermined Problems
    The diagnostic problems does not identify which adapter or device failed, which installed devices are incorrect, 
    whether a short circuit is suspected, or whether the system is inoperative.  
    Follow these procedures to isolate the failing FRU (do not isolate non-defective FRU).
    NOTE: Verify that all attached devices are supported by the computer.
    NOTE: Verify that the power supply being used at the time of the failure is operating correctly. (See “Power 
    System Check” on page 111.):
    1.Power-off the computer.
    2.Visually check them for damage. If any problems are found, replace the FRU.
    3.Remove or disconnect all of the following devices:
    •Non-Acer devices
    •Printer, mouse, and other external devices
    •Battery pack
    •Hard disk drive
    •DIMM 
    •CD-ROM/Diskette drive Module
    •PC Cards
    4.Power-on the computer.
    5.Determine if the problem has changed.
    6.If the problem does not recur, reconnect the removed devices one at a time until you find the failing FRU.
    7.If the problem remains, replace the following FRU one at a time. Do not replace a non-defective FRU:
    •System board
    •LCD assembly 
    						
    							Chapter 4129 
    						
    All Acer manuals Comments (0)