Page 51
Chapter 4 4-5 Flash Memory Update: The flash Memory Update: The flash memory update is required for the following conditions: • New versions of system programs • New features or options Power System Checkout To verify the symptom of the problem, power on the computer using each of the following power sources: 1. Remove the battery pack and diskette drive. 2. Connect the AC Adapter and check that power is supplied. 3. Disconnect the AC Adapter and install the charged battery pack; then check that...
Page 52
4-6 EXTENSA 700/710 Service Guide : If the voltage is not correct, replace the AC Adapter. If the voltage is within the range, do the following: • Replace the Main board. • If the problem is not corrected, go to “Undetermined Problems”. • If the voltage is not correct, go to the next step. Note: An audible noise from the AC Adapter does not always indicate a defect. Checking Operational Charging: To check operational charging, use a discharged battery pack or a battery pack that has less than 50%...
Page 53
Chapter 4 4-7 1. Power off the computer. 2. Remove the battery pack and measure the voltage between battery terminals 1 (+) and 7. See the following figure: If the voltage is still less than +10.0 Vdc after recharging, replace the battery. TouchPad Checkout If the TouchPad does not work, check the configuration in the ThinkPad BIOS program. If the configuration of the TouchPad is disabled, select Enable to enable it. If this does not correct the TouchPad problem, continue with the following. After...
Page 54
4-8 EXTENSA 700/710 Service Guide Symptom-to-Spare Part Index The symptom-to-Spare Part index lists the symptoms and errors and their possible causes. The most likely cause is listed first. Note: Perform the Spare Part replacement or actions in the sequence shown in the “Spare Part/Action” columns. If a Spare Part replacement did not solve the problem, put the original part back in the computer. Do not replace a nondefective Spare Part. This index can also help you determine the next possible Spare...
Page 55
Chapter 4 4-9 0220 Monitor type does not match CMOS - Run Setup1. Run “Load Setup Defaults” in BIOS Setup Utility. 0230 Shadow RAM Failed at offset: nnnn1. BIOS ROM 2. Main board 0231 System RAM Failed at offset: nnnn1. DIMM 2. Main board 0232 Extended RAM Failed at offset:nnnn1. DIMM 2. Main board 0250 System battery is dead - Replace and run Setup1. Replace backup battery(RTC) and Run SETUP to reconfigure System time, then reboot system. 0251 System CMOS checksum bad - Default...
Page 56
4-10 EXTENSA 700/710 Service Guide 02F5 DMA Test Failed1. DIMM 2. IMM (CPU board) 3. Main board 02F6 Software NMI Failed1. DIMM 2. IMM (CPU board) 3. Main board 02F7 Fail-Safe Timer NMI Failed1. DIMM 2. IMM (CPU board) 3. Main board Error Messages Symptom / Error Spare Part / Action in Sequence Device Address Conflict 1. Run “Load Setup Defaults” in BIOS Setup Utility. 2. Backup battery (RTC) 3. Main board Allocation Error for: device 1. Run “Load Setup Defaults” in BIOS Setup Utility. 2....
Page 57
Chapter 4 4-11 No beep, power-on indicator not on, and a blank LCD during POST1. Reseat LCD connectors 2. LCD inverter ID 3. LCD FPC cable 4. LCD inverter 5. LCD 6. LED board 7. Main board No beep, power-on indicator on, and a blank LCD during POST.1. Reseat the LCD connectors 2. LCD inverter ID 3. LCD FPC Cable 4. LCD inverter 5. LCD 6. Main board No beep during POST but system runs correctly.1. Speaker LCD-Related Symptoms Symptom / ErrorSpare Part / Action in Sequence • LCD...
Page 58
4-12 EXTENSA 700/710 Service Guide Indicator-Related Symptoms Symptom / ErrorSpare Part / Action in Sequence Indicator incorrectly remains off or on, but system runs correctly1. Reseat the LED board 2. LED board 3. Main board Power-Related Symptoms Symptom / ErrorSpare Part / Action in Sequence Power shuts down during operation1. Battery 2. AC Adapter 3. DC/DC & Charge board 4. Main board The system will not power-on. 1. Battery 2. AC adapter 3. DC/DC & Charge boar 4. Main board The system...
Page 59
Chapter 4 4-13 Note: If you cannot find a symptom or an error in this list and the problem remains, see “Undetermined Problems”. Intermittent Problems Intermittent system hang problems can be caused by a variety of reasons that have nothing to do with a hardware defect, such as: cosmic radiation, Power Management-Related Symptoms Symptom / ErrorSpare Part / Action in Sequence The system will not enter hibernation1. Keyboard (if control is from the keyboard) 2. Hard disk 3. Main board The system...
Page 60
4-14 EXTENSA 700/710 Service Guide electrostatic discharge, or software errors. Spare Part replacement should be considered only when a recurring problem exists. When analyzing an intermittent problem, do the following: 1. Run the advanced diagnostic test for the Main board in loop mode at least 10 times. 2. If no error is detected, do not replace any Spare Part. 3. If any error is detected, replace the Spare Part shown by the Spare Part code. Rerun the test to verify that no more errors exist....