Home > Acer > Notebook > Acer Aspire 7315 Service Guide

Acer Aspire 7315 Service Guide

Here you can view all the pages of manual Acer Aspire 7315 Service Guide. The Acer manuals for Notebook are available online for free. You can easily download all the documents as PDF.

Page 141

Chapter 4131
ODD Failure
If the ODD fails, perform the following actions one at a time to correct the problem. Do not replace a non-
defective FRUs:
ODD Not Operating Correctly
If the ODD exhibits any of the following symptoms it may be faulty:
• Audio CDs do not play when loaded 
• DVDs do not play when loaded 
• Blank discs do not burn correctly 
• DVD or CD play breaks up or jumps 
• Optical drive not found or not active: 
• Not shown in My Computer or the BIOS setup 
• LED does not flash when the...

Page 142

132Chapter 4
a.Double-click lDE ATA/ATAPI controllers. If a device displays a down arrow, right-click on the device 
and click Enable.
b.Double-click DVD/CD-ROM drives. If the device displays a down arrow, right-click on the device and 
click Enable.
c.Check that there are no yellow exclamation marks against the items in l D E  ATA / ATA P I  c o n t r o l l e r s. If 
a device has an exclamation mark, right-click on the device and uninstall and reinstall the driver.
d.Check that there are no yellow...

Page 143

Chapter 4133
b.Double-click IDE ATA/ATAPI controllers, then right-click ATA Device 0. 
c.Click Properties and select the Advanced Settings tab. Ensure that the Enable DMA box is 
checked and click OK. 
d.Repeat for the other ATA Devices shown if applicable.
Drive Not Detected
If Windows cannot detect the drive, perform the following actions one at a time to correct the problem.
1.Restart the computer and press F2 to enter the BIOS Utility. 
2.Check that the drive is detected in the ATAPI Model Name field...

Page 144

134Chapter 4
Wireless Function Failure
If the WLAN fails, perform the following actions one at a time to correct the problem. Do not replace a non-
defective FRUs:
Thermal Unit Failure
If the Thermal Unit fails, perform the following actions one at a time to correct the problem. Do not replace a 
non-defective FRUs: 

Page 145

Chapter 4135
External Mouse Failure
If an external Mouse fails, perform the following actions one at a time to correct the problem. 
1.Try an alternative mouse.
2.If the mouse uses a wireless connection, insert new batteries and confirm there is a good connection. See 
the mouse user manual.
3.If the mouse uses a USB connection, try an alternate USB port.
4.Try an alternative program to verify mouse operation. Reinstall the program experiencing mouse failure.
5.Restart the computer.
6.Remove any recently...

Page 146

136Chapter 4
Intermittent Problems
Intermittent system hang problems can be caused by a variety of reasons that have nothing to do with a 
hardware defect, such as: cosmic radiation, electrostatic discharge, or software errors. FRU replacement 
should be considered only when a recurring problem exists.
When analyzing an intermittent problem, do the following:
1.Run the advanced diagnostic test for the system board in loop mode at least 10 times.
2.If no error is detected, do not replace any FRU.
3.If any...

Page 147

Chapter 4137
Post Codes
These tables describe the POST codes and descriptions during the POST.
Sec:
NO_EVICTION_MODE_DEBUG EQU 1 (CommonPlatform\sec\Ia32\SecCore.inc)
Memory:
DEBUG_BIOS equ 1 (Chipset\Alviso\MemoryInitAsm\IA32\IMEMORY.INC)
CodeDescription
0xC2 MTRR setup
0xC3 Enable cache
0xC4 Establish cache tags
0xC5 Enter NEM, Place the BSP in No Fill mode, set CR0.CD = 1, CR0.NW = 0.
0xCF Cache Init Finished
CodeDescription
0xA0 First memory check point
0x01 Enable MCHBAR
0x02 Check for DRAM...

Page 148

138Chapter 4
BDS & Specific action:
0x27 Enable DRAM Channel I/O Buffers
0x28 Enable all clocks on populated rows
0x29 Perform JEDEC memory initialization for all memory rows
0x30 Perform steps required after memory init
0x31 Program DRAM throttling and throttling event registers
0x32 Setup DRAM control register for normal operation and enable
0x33 Enable RCOMP
0x34 Clear DRAM initialization bit in the SB
0x35 Initialization Sequence Completed, program graphic clocks
0xAF Disable access to the XMM...

Page 149

Chapter 4139
0xF8 Report that ExitBootServices () has been called
0xF9 Runtime driver set virtual address map
CodeDescription 

Page 150

140Chapter 4
Each PEIM entry point used in 80_PORT
Each Driver entry point used in 80_PORT
CodeDescription
0x00
0x01 PEI_EVENT_LOG
0x02 PEI_OEM_SERVICE
0x03 PEI_SIO_INIT
0x04 PEI_MONO_STATUS_CODE
0x05 PEI_CPU_IO_PCI_CFG
0x06 PEI_CPU_IO
0x07 PEI_PCI_CFG
0x08 PEI_CPU_PEIM
0x09 PEI_PLATFORM_STAGE1
0x0A PEI_VARIABLE
0x0B PEI_SB_INIT
0x0C PEI_CAPSULE
0x0D PEI_PLATFORM_STAGE2
0x0E PEI_SB_SMBUS_ARP_DISABLED
0x0F PEI_HOST_TO_SYSTEM
0x10 PEI_MEMORY_INIT
0x11 PEI_S3_RESUME
0x12 PEI_CLOCK_GEN
0x13 PEI_OP_PRESENCE...
Start reading Acer Aspire 7315 Service Guide

Related Manuals for Acer Aspire 7315 Service Guide

All Acer manuals