Acer Aspire 5332 Service Guide
Here you can view all the pages of manual Acer Aspire 5332 Service Guide. The Acer manuals for Notebook are available online for free. You can easily download all the documents as PDF.
Page 141
Chapter 4131 Sound Problems If sound problems are experienced, perform the following actions one at a time to correct the problem. 1.Reboot the computer. 2.Navigate to Start´ Control Panel´ System and Maintenance´ System´ Device Manager. Check the Device Manager to determine that: • The device is properly installed. • There are no red Xs or yellow exclamation marks. • There are no device conflicts. • No hardware is listed under Other Devices. 3.Roll back the audio driver to the previous version, if...
Page 142
132Chapter 4 HDD Not Operating Correctly If the HDD does not operate correctly, perform the following actions one at a time to correct the problem. 1.Disconnect all external devices. 2.Run a complete virus scan using up-to-date software to ensure the computer is virus free. 3.Run the Windows OS Startup Repair Utility: a.Insert the Windows Operating System DVD in the ODD and restart the computer. b.When prompted, press any key to start to the operating system DVD. c.The Install Windows screen...
Page 143
Chapter 4133 ODD Failure If the ODD fails, perform the following actions one at a time to correct the problem. Do not replace a non- defective FRUs: ODD Not Operating Correctly If the ODD exhibits any of the following symptoms it may be faulty: • Audio CDs do not play when loaded • DVDs do not play when loaded • Blank discs do not burn correctly • DVD or CD play breaks up or jumps • Optical drive not found or not active: • Not shown in My Computer or the BIOS setup • LED does not flash when the...
Page 144
134Chapter 4 a.Double-click lDE ATA/ATAPI controllers. If a device displays a down arrow, right-click on the device and click Enable. b.Double-click DVD/CD-ROM drives. If the device displays a down arrow, right-click on the device and click Enable. c.Check that there are no yellow exclamation marks against the items in l D E ATA / ATA P I c o n t r o l l e r s. If a device has an exclamation mark, right-click on the device and uninstall and reinstall the driver. d.Check that there are no yellow...
Page 145
Chapter 4135 b.Double-click IDE ATA/ATAPI controllers, then right-click ATA Device 0. c.Click Properties and select the Advanced Settings tab. Ensure that the Enable DMA box is checked and click OK. d.Repeat for the other ATA Devices shown if applicable. Drive Not Detected If Windows cannot detect the drive, perform the following actions one at a time to correct the problem. 1.Restart the computer and press F2 to enter the BIOS Utility. 2.Check that the drive is detected in the ATAPI Model Name field...
Page 146
136Chapter 4 Wireless Function Failure If the WLAN fails, perform the following actions one at a time to correct the problem. Do not replace a non- defective FRUs: Thermal Unit Failure If the Thermal Unit fails, perform the following actions one at a time to correct the problem. Do not replace a non-defective FRUs:
Page 147
Chapter 4137 External Mouse Failure If an external Mouse fails, perform the following actions one at a time to correct the problem. 1.Try an alternative mouse. 2.If the mouse uses a wireless connection, insert new batteries and confirm there is a good connection. See the mouse user manual. 3.If the mouse uses a USB connection, try an alternate USB port. 4.Try an alternative program to verify mouse operation. Reinstall the program experiencing mouse failure. 5.Restart the computer. 6.Remove any recently...
Page 148
138Chapter 4 Intermittent Problems Intermittent system hang problems can be caused by a variety of reasons that have nothing to do with a hardware defect, such as: cosmic radiation, electrostatic discharge, or software errors. FRU replacement should be considered only when a recurring problem exists. When analyzing an intermittent problem, do the following: 1.Run the advanced diagnostic test for the system board in loop mode at least 10 times. 2.If no error is detected, do not replace any FRU. 3.If any...
Page 149
Chapter 4139 Post Codes These tables describe the POST codes and descriptions during the POST. Sec: NO_EVICTION_MODE_DEBUG EQU 1 (CommonPlatform\sec\Ia32\SecCore.inc) Memory: DEBUG_BIOS equ 1 (Chipset\Alviso\MemoryInitAsm\IA32\IMEMORY.INC) CodeDescription 0xC2 MTRR setup 0xC3 Enable cache 0xC4 Establish cache tags 0xC5 Enter NEM, Place the BSP in No Fill mode, set CR0.CD = 1, CR0.NW = 0. 0xCF Cache Init Finished CodeDescription 0xA0 First memory check point 0x01 Enable MCHBAR 0x02 Check for DRAM...
Page 150
140Chapter 4 BDS & Specific action: 0x27 Enable DRAM Channel I/O Buffers 0x28 Enable all clocks on populated rows 0x29 Perform JEDEC memory initialization for all memory rows 0x30 Perform steps required after memory init 0x31 Program DRAM throttling and throttling event registers 0x32 Setup DRAM control register for normal operation and enable 0x33 Enable RCOMP 0x34 Clear DRAM initialization bit in the SB 0x35 Initialization Sequence Completed, program graphic clocks 0xAF Disable access to the XMM...