Page 81

71Chapter 4
Check the Power Adapter
Unplug the power adapter cable from the computer and measure the output voltage at the plug of the power 
adapter cable. See the following figure
1.If the voltage is not correct, replace the power adapter.
2.If the voltage is within the range, do the following:
TReplace the System board.
TIf the problem is not corrected, see “Undetermined Problems” on page 82.
TIf the voltage is not correct, go to the next step.
NOTE: An audible noise from the power adapter does not...

Page 82

Chapter 472
Check the Battery Pack 
To check the battery pack, do the following:
From Software:
1.Check out the Power Management in control Panel
2.In Power Meter, confirm that if the parameters shown in the screen for Current Power Source and Total 
Battery Power Remaining are correct.
3.Repeat the steps 1 and 2, for both battery and adapter.
4.This helps you identify first the problem is on recharging or discharging. 
From Hardware:
1.Power off the computer. 
2.Remove the battery pack and measure the...

Page 83

73Chapter 4
Power-On Self-Test (POST) Error Message 
The POST error message index lists the error message and their possible causes. The most likely cause is 
listed first.
NOTE: Perform the FRU replacement or actions in the sequence shown in FRU/Action column, if the FRU 
replacement does not solve the problem, put the original part back in the computer. Do not replace a 
non-defective FRU.
This index can also help you determine the next possible FRU to be replaced when servicing a computer.
If the...

Page 84

Chapter 474
Index of Error Messages
Error Code List
Error CodesError Messages
006 Equipment Configuration Error
Causes:
1. CPU BIOS Update Code Mismatch
2. IDE Primary Channel Master Drive Error
(THe causes will be shown before “Equipment Configuration 
Error”)
010 Memory Error at xxxx:xxxx:xxxxh (R:xxxxh, W:xxxxh) 
070 Real Time Clock Error
071 CMOS Battery Bad
072 CMOS Checksum Error
110 System disabled.
Incorrect password is specified.
 Battery critical LOW
In this situation BIOS will issue 4 short...

Page 85

75Chapter 4
Real time clock error RTC battery
Run BIOS Setup Utility to reconfigure system time, then reboot 
system.
System board
Previous boot incomplete - Default configuration 
usedRun “Load Default Settings” in BIOS Setup Utility.
RTC battery
System board
Memory size found by POST differed from 
CMOSRun “Load Default Settings” in BIOS Setup Utility.
DIMM
System board
Diskette drive A error Check the drive is defined with the proper diskette type in BIOS 
Setup Utility
See “External Diskette Drive...

Page 86

Chapter 476
Error Message List
No beep Error MessagesFRU/Action in Sequence
No beep, power-on indicator turns off and LCD is 
blank.Power source (battery pack and power adapter). See “Power 
System Check” on page 70. 
Ensure every connector is connected tightly and correctly. 
Reconnect the DIMM.
LED board.
System board.
No beep, power-on indicator turns on and LCD is 
blank.Power source (battery pack and power adapter). See “Power 
System Check” on page 70. 
Reconnect the LCD connector
Hard disk drive...

Page 87

77Chapter 4
POST Code
CodeBeepsFor Boot Block in Flash ROM
E0h Initialize the chipset
E1h Initialize the bridge
E2h Initialize the CPU
E3h Initialize the system timer
E4h Initialize system I/O
E5h Check force recovery boot
E6h Checksum BIOS ROM
E7h Go to BIOS
E8h Set Huge Segment
E9h Initialize Multi Processor
EAh Initialize OEM special code
EBh Initialize PIC and DMA
ECh Initialize Memory type
EDh Initialize Memory size
EEh Shadow Boot Block
EFh System memory test
F0h Initialize interrupt vectors
F1h...

Page 88

Chapter 478
Index of Symptom-to-FRU Error Message
LCD-Related Symptoms
Symptom / ErrorAction in Sequence
LCD backlight doesnt work
LCD is too dark
LCD brightness cannot be adjusted
LCD contrast cannot be adjustedEnter BIOS Utility to execute “Load Setup Default Settings”, then 
reboot system.
Reconnect the LCD connectors.
Keyboard (if contrast and brightness function key doesnt work).
LCD inverter ID
LCD cable
LCD inverter
LCD
System board
Unreadable LCD screen 
Missing pels in characters
Abnormal screen...

Page 89

79Chapter 4
Battery can’t be charged See “Check the Battery Pack” on page 72. 
Battery pack
System board
PCMCIA-Related Symptoms
Symptom / ErrorAction in Sequence
System cannot detect the PC Card (PCMCIA)  PCMCIA slot assembly
System board
PCMCIA slot pin is damaged. PCMCIA slot assembly
Memory-Related Symptoms
Symptom / ErrorAction in Sequence
Memory count (size) appears different from 
actual size.Enter BIOS Setup Utility to execute “Load Default Settings, then 
reboot system.
DIMM
System board...

Page 90

Chapter 480
NOTE: If you cannot find a symptom or an error in this list and the problem remains, see “Undetermined 
Problems” on page 82.
Battery fuel gauge in Windows doesn’t go higher 
than 90%. Remove battery pack and let it cool for 2 hours.
Refresh battery (continue use battery until power off, then charge 
battery).
Battery pack
System board
System hangs intermittently. Reconnect hard disk/CD-ROM drives. 
Hard disk connection board
System board
Peripheral-Related Symptoms
Symptom / ErrorAction in...