Page 1
Aarrow Fires Ltd The Fireworks Bridport Dorset, DT6 3BE Great Britain Tel. (44) 01308 427234 Fax. (44) 01308 423441 www.aarrowfires.com Acorn Multifuel Stoves Operating & Installation Manual PLEASE RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE The Acorn 4 Multifuel Stove (shown above) Rev 2 Part No: AFS1126 March 2004
Page 2
Congratulations on your choice of an Aarrow Stove. More than 20 years experience has been put into the development of our Acorn Multifuel to ensure ultimate performance and years of trouble free enjoyment. Every detail on the fire has been carefully engineered and designed which is why we are so confident in the reliability of our product that we offer a 3 year guarantee. Should you have any questions about our Acorn Stoves that are not covered in this manual, please contact the Aarrow dealer in your...
Page 3
INTRODUCTION Page Safety Notices 5 The Principle of the Fire 5 Check List 6 Technical Data 7 INSTALLATION Page General Precautions 8 Handling 8 Hearth 8 Combustible Materials 8 Air For Combustion 8 Firebox Liner Panels 9 Removal of the Throat Plate 9 Fitting the Optional Floor Fixing Kit 9 Assembling the Multifuel Grate 10 Flues & Chimneys 11-14 Add in Boilers 15-16OPERATING INSTRUCTIONS Page AirInlet Controls 16-17 Airwash System 16-17...
Page 4
WARNING TO ALL MULTIFUEL USERS PETROLEUM COKE SOME OF WHOSE BRAND NAMES ARE CALCO, PETROCOKE OR WONDERCO MUST NOT BE BURNED IN THIS APPLIANCE TO USE THESE FUELS WILL INVALIDATE THE APPLIANCE GUARANTEE IF IN DOUBT CONTACT THE SOLID FUEL ASSOCIATION TELEPHONE NUMBER 0800 600 000 www.solidfuel.co.uk THE USE OF SPARE PARTS OTHER THAN THOSE SUPPLIED BY AARROW FIRES LTD WILL INVALIDATE THE APPLIANCE GUARANTEE. 4Acorn Multifuel Stoves
Page 5
Acorn Multifuel Stoves5 INTRODUCTION SAFETY A fireguard conforming to BS 8423: 2002 should be used in the presence of children and old/or infirm people. If the appliance is used with the fire door open, a spark guard conforming to BS 3248 should be fitted. Do not use aerosol sprays or any other flame near the appliance under fire. Do not fit an extractor fan in the same room as the appliance. Fire cement is caustic, hand and eye protection should always be worn, prolonged contact with the skin should be...
Page 6
Inside the appliance you should find the following: 6Acorn Multifuel Stoves CHECK LIST Part Description & Visual Aid (not to scale)Acorn 4 Multifuel Quanity Part No. 1. Grate bars 5 2. Integral front brace/ reatainer 1 3. Throat plate 1 4. Flue spigot 1(4”) 5. Hot plate 1(4”) 6. Ash pan 1 7.Operating tool 1 8. Rear liners 1 9. Side liners 2 10. Fire door handle 1 11. Instructions1 The model and Serial Number of your fire can be found stamped into the casing, centrally just below the bottom edge of the...
Page 7
Acorn Multifuel Stoves7 TECHNICAL DATA Room Min/Max Room Heater Only Output (kW) 1- 4.5 TECHNICAL DATA Acorn 4 Multifuel Room Heater with Domestic Hot Water with add in boilertypeType 7 Max Output to Room (kW) Max Output to Water (kW)3 1.5 Height (mm)458 Width (mm)355 Depth (mm)350 Height to Centre of Rear Flue 360 Depth from Back to Centre of Flue 90 Flue Diameter (mm)102 (4”) Weight Unpacked Packed 43 Kg 46 Kg Acorn 5 Multifuel 1 - 5 Type 0 3 2 483 395 350 387.5 96 102 (4”) 44 Kg 47 Kg
Page 8
8Acorn Multifuel Stoves INSTALLATION GENERAL PRECAUTIONS Note - All installations must conform to the appropriate building regulations. The Building Regulations for England and Wales 2000 ref Approved Document J 2002 edition (issued by the DTLR). The Building Standards (Scotland) (Consolidation) Regulations. Detailed recommendations for installation of appliances, chimneys and flues are outlined in the current issue of the following British Standards:- BS6461, BS8303 and BS4543. Any Manufacturers...
Page 9
FIREBOX LINER PANELS The Acorn Multifuel stoves have reflective liners to the sides and back. The throat plate sits on top of the side and rear panels. These should come fitted to your fire, if however they are not proceed as follows to fit them. •Remove the front brace retainer. •Set the small liner into the back of the fire. •Insert side liner panels •Fit the throat plate with the single bend and two cut outs to the front facing up. The projecting lugs sit on top of the side liners. The long centre...
Page 10
MULTIFUEL GRATE GRATE The grates in the Acorn Multifuel units comprise a series of reciprocating cast iron bars seated on a pivoted comb. All bars in the grate are identical, but every other bar is turned through 180 degrees, with the ends of the bars marked H sitting on the high sections of the comb, and the ends marked L sitting on the low sections. ASSEMBLING THE GRATE To assemble the grate, fit bars to low sections of the comb first, inserting end marked H into rear channel with groove on underside...