TECHNICAL A-8© 3M 1999 3Mª Multimedia Projector MP8780 Serial mouse A.7 Connection to the Control Signal Terminal (continued) RS-232 Control Cable (not included with basic packout) This cable is used to directly control the projector without using the Remote Control or Operators Panel. Computer Projector 15 D-sub 9-pin (Female) 69 1 2 3 4 5 6 7 8 9 Shield Mini Din 9-pin (Male) 2 1 56 89 4 3 7 1 2 3 4 5 6 7 8 9 Shield Not available for this printing.
© 3M 1999 3Mª Multimedia Projector MP8780 TECHNICAL A-9 A.7 Connection to the Control Signal Terminal (continued) USB Mouse Cable This cable is used to connect the projector and computer to allow computer mouse control via the projectors remote control buttons. Connect the cable, select the input source where the computer is to be connected and start the mouse functions. 4 Note Some laptop computers with a built-in pointing device (track ball) may not recognize the external mouse. In this case, change the BIOS (system setup) so that an external mouse can be selected. Some computers may not have the necessary utility program to operate a mouse. Refer to the computer hardware manual. 1 2 3 42 USB Mouse Jack (B Type) 1 34 Projector NC –DATA +DATA GNDComputer +5V –DATA +DATA GND 1 2 3 4 USB Cable USB Mouse Jack (A Type) 34 2 1
TECHNICAL A-10© 3M 1999 3Mª Multimedia Projector MP8780 Command Code Formats All codes in this document are in ASCII Text. In order to get this to work you must send at the same communication setting as the projector. This should be 9600 8N1. For the rest of this document CR is a carriage return which is code 13. There are two types of commands that can be sent to the projector. They are Write or Read commands. Write Command Format User: Code CR Projector (if it worked): OKCR Projector (if it did not work): NGCR Read Command Format User: Code CR Projector (if it worked): Data O K CR Projector (if it did not work): NGCR A.8 Serial Inferface Command Codes
© 3M 1999 3Mª Multimedia Projector MP8780 TECHNICAL A-11 A.8 Serial Inferface Command Codes (continued) Function Code Meaning Power On/Off Write Codes D00W00 Power On D00W01 Power Off Read Codes Returns: D00R 00 - Standby 01 - Power on but no lamp 02 - Power on and lamp 03 - Power off but fan running Source Selection Write Codes D02W01 RGB 1 D02W02 RGB 2 D02W03 RGB 3 D02W11 Video 1 D02W12 Video 2 D02W13 Video 3 D03W00 Shows what input is selected on-screen Read Codes Returns: D02R 01 Ð RGB 1 02 Ð RGB 2 03 Ð RGB 3 11 Ð Video 1 12 Ð Video 2 13 Ð Video 3 Volume Control Write Codes Sets volume level to a value between 00 and 14 hex. D04W00 to This corresponds to 20 possible settings. D04W14 Read Codes Returns: D04R 00 to 14 hex Focus Control Write Codes D05W00 300ms Clockwise D05W01 300ms Counterclockwis D05W10 Continuous Clockwise D05W11 Continuous Counterclockwise D05W20 Turn off motor Zoom Write Codes D06W00 300ms Clockwise D06W01 300ms Counterclockwise D06W10 Continuous Clockwise D06W11 Continuous Counterclockwise D06W20 Turn off motor Mute Write Codes D07W00 Mute off D07W01 Mute on Read Codes Returns: D07R 00 - mute is off 01 - mute is on Blank Write Codes D08W00 Blank is off - image is shown D08W01 Blank is on - black screen is shown Read Codes Returns: D08R 00 - off 01 - on
TECHNICAL A-12© 3M 1999 3Mª Multimedia Projector MP8780 A.8 Serial Inferface Command Codes (continued) Function Code Meaning Contrast Write Codes D12W00 to D12W14 Set contrast level to a value between 00 and 14 hex. This corresponds to 20 possible settings. Read Codes Returns: D12R 00 to 14 hex Brightness Write Codes D13W00 to D13W14 Sets brightness level to a value between 00 and 14 hex. This corresponds to 20 possible settings. Read Codes Returns: D13R 00 to 14 hex Tint (Hue) Write Codes D14W00 to D14W14 Sets tint (hue) level to a value between 00 and 14 hex. This corresponds to 20 possible settings. Read Codes Returns: D14R 00 to 14 hex Color (Saturation) Write Codes D15W00 to D15W14 Sets color (saturation) level to a value between 00 and 14 hex. This corresponds to 20 possible settings. Read Codes Returns: D15R 00 to 14 hex Sharpness Write Codes D16W00 to D16W14 Sets sharpness level to a value between 00 and 14 hex. This corresponds to 20 possible settings. Read Codes Returns: D16R 00 to 14 hex Gamma Write Codes Sets sharpness level to a value between 00 and 14 hex. D17W00 to D17W14 This corresponds to 20 possible settings. Read Codes Returns: D17R 00 to 14 hex PC Mode Read Codes Returns: D30R 0 to 41 hex See Computer (RGB) Signal Connection (Section AÐ5) 00-Shows no input MAC Mode Write Codes D32W00 MAC MODE ÒOFFÓ D32W01 MAC MODE ÒONÓ Default is ÒOFFÓ Read Codes Returns: D32R 00-MAC MODE is OFF 01-MAC MODE is ON Phase Write Codes D34W00 to D34W13 Set phase to a value in the range of 00 to 13 hex. D35W00 Reset phase to default Read Codes Returns: D34R 00 to 13 hex
© 3M 1999 3Mª Multimedia Projector MP8780 TECHNICAL A-13 A.8 Serial Inferface Command Codes (continued) Function Code Meaning Display Position Write Codes D36W00 to D36WFE Change vertical display position (up/down) from reset position by 00 to FE. D37W00 to D37WFE Change horizontal display position (left/right) from reset position by 00 to FE. D38W00 Resets display position Read Codes Returns: D36R 00 to FE vertical position D37R 00 to FE horizontal position H-Size Write Codes The 00 to 80 denotes the deviation of clock numbers from D39W00 to D39W80 the standard in one horizontal period. Ò40Ó is zero, Ò00Ó is - 64 and Ò80Ó is +64 decimal. Default value is Ò40Ó Read Codes Returns: D39R 00 to 80 hex OnÐScreen Displays Write Codes D51W00 Disables onÐscreen display except ÒWARNINGÓ D51W01 Enables onÐscreen display Read Codes 00-OnÐscreen display is disabled D51R 01-OnÐscreen display is enabled Language Selection Write Codes D52W00 English D52W01 French D52W02 Spanish D52W03 German D52W04 Dutch D52W05 Italian D52W06 Swedish Read Codes Returns: D52R 00 - English 01 - French 02 - Spanish 03 - German 04 Ð Dutch 05 Ð Italian 06 - Swedish Mirror (H/V Inversion) Write Codes D53W00 NORMAL D53W01 HÐINVERT D53W02 VÐINVERT D53W03 H&VÐINVERT Read Codes Returns: D53R 00-NORMAL 01-HÐINVERT 02-VÐINVERT 03-H&VÐINVERT Auto Off Write Codes D55W00 Disables auto off D55W01 Enables auto off Default is ÒNOÓ auto off Read Codes Returns: D55R 00-Auto off is disabled 01-Auto off is enabled
TECHNICAL A-14© 3M 1999 3Mª Multimedia Projector MP8780 A.8 Serial Inferface Command Codes (continued) Function Code Meaning IR receiver selection Write Codes D5AW00 Selects Front and Rear IR Receiver D5AW01 Selects Front IR Receiver D5AW02 Selects Rear IR Receiver Read Codes Returns: D5AR 00-Front and Rear Receiver is selected 01-Front receiver is selected 02-Rear receiver is selected Magnify Write Codes D5BW00 D5BW01XY to 01:x1, 02:x2, 03:x4, 04:x8, 05:x16, 06:x32, 07:x64 D5BW07XY XYdenotes magnifying portion (00 to FF) Read Codes D5BR 00 Ð Off 01 to 07 PIP Write Codes D5CW00 Off D5CW01 ON1 D5CW02 ON2 D5CW03 Refreshes the background for ON1 Read Codes Returns: D5CR 00 Ð Off 01 Ð ON1 02 Ð ON2 Lamp Timer Reset Write Codes D60W00 Resets the lamp timer Read Codes Returns: D60R xxxx-shows lamp operating time in hours (decimal) Temperature Read Codes Returns: D61R Shows the status of internal temperature 00-Temperature level 0 01-Temperature level 1 02-Temperature level 2 03-Temperature level 3 04-Temperature level 4 (Warning) 05-Temperature level 5 (Power Off) Error Status Read Codes Returns: D01R 00-No error 01-Interlock error 02-Lamp error 04-Temperature error 08-Fan error 10-Memory error Note: If there is more than one error, the resulting read code will be the sum f the error codes listed above. Example: For Interlock-01 and Lamp-02, resulting read code is 03.
3M Austin Center Building A145-5N-01 6801 River Place Blvd. Austin, TX 78726-90003M Canada P.O. Box 5757 London, Ontario N6A 4T13M Mexico, S.A. de C.V. Apartado Postal 14-139 Mexico, D.F. 07000 Mexico3M Europe Boulevard de lOise 95006 Cerge Pontoise Cedex FranceLitho in USA Copyright © 1999 3M IPC. All Rights Reserved 78-6970-9001-3 Rev. A Important Notice All statements, technical information, and recommendations related to 3MÕs products are based on information believed to be reliable, but the accuracy or completeness is not guaranteed Before using this product, you must evaluate it and determine if it is suitable for your intended application. You assume all risks and liability associated with such use. Any statements related to the product which are not contained in 3MÕs current publications, or any contrary statements contained on your purchase order shall have no force or effect unless expressly set forth in a written agreement signed by an authorized officer of 3M. Warranty and Limited Remedy. This product will be free from defects in material and manufacture for a period of two years from the date of purchase. 3M MAKES NO OTHER WARRANTIES INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. If this product is defective within the warranty period stated above, your exclusive remedy shall be, at 3MÕs option, to replace or repair the 3M product or refund the purchase price of the 3M product. Limitation of Liability. Except where prohibited by law, 3M will not be liable for any loss or damage arising from this 3M product, whether direct, indirect, special, incidental or consequential regardless of the legal theory asserted. Let us help you make the most of your next presentation. We offer everything from presentation supplies to tips for better meetings. And were the only transparency manufacturer that offers a recycling program for your used transparencies. For late-breaking news, handy reference and free product samples, call us toll-free in the continental United States and Canada, 24 hours a day, or visit our Internet Website.