78-9000-0192-2 Rev D 31
E. Directional Null (DirNull)
TRACE [2] + Mode [SK] + DirNull [SK Toggle]  
or Menu/OK [5] + Cable/Pipe [SK] + Mode [SK] + DirNull [SK Toggle]
In Directional Null mode, as the operator approaches the cable or pipe, the numerical 
Signal Strength [9] ([8] for 2550 locator) will increase then fall sharply as the receiver 
crosses the target cable or pipe. The Bar Graph [11] ([10] for 2550 locator) fills from 
both sides toward the middle and the receiver speaker volume decreases. As...

Page 32

 32 78-9000-0192-2 Rev D
F.  Expanded Mode
VOL [13] (press up arrow)
When the third ring of the speaker icon is dotted 
or broken and ‘xpnd’ appears below the speaker 
icon as shown, the receiver is in “Expanded” 
mode. This mode is used for pinpointing a 
target cable or pipe. The area of response of the 
receiver narrows, allowing the locator to detect 
very small signal changes. Press the Speaker 
Volume Control [13] ([12] for 2550 locator) key 
to activate the “Expanded” mode.
8.  Depth and Current...

Page 33

78-9000-0192-2 Rev D 33
• Optional step: Press Clear All  [SK] to delete all 
stored depth information.
 
− The operator may select a specific memory 
location to store the depth readings by pressing 
Mem Select [SK]. When the preferred location 
appears on the display, press Save [SK]. The 
display and memory location will populate with 
the current information.
 
− Each memory location can be reviewed by 
pressing Mem Select [SK].
•  Press  TRACE [2] or DEPTH [4] to return to Locate 
mode, or wait...

Page 34

 34 78-9000-0192-2 Rev D
• Press  Cable/Pipe [SK]
•  Press  Freq [SK]
•  Press  Power  [SK Toggle] until the desired frequency is displayed: (“Power” 60, 60L, 
60H, or 120).
•  Press Menu/OK [5] to return to Locate mode.
All U.S. receivers default to 60 Hz.
To set the receiver to detect 50 Hz signals refer to 5.D.  Enabling/Disabling Locating 
Frequencies  section of this manual.
C. Passive Frequencies
The receiver (without a 3M™ Dynatel™ Transmitter 2500 Series) can be used to detect 
some CATV cables...

Page 35

78-9000-0192-2 Rev D 35
10. Locating in Directional Peak Mode
The following are instructions for locating a buried pipe or cable using the direct connect 
method and the Directional Peak (Dir Pk) mode. Other methods of connection and 
tracing modes/features are explained in previous sections.
Step 1.  Insert the ground rod into the ground, perpendicular to the suspected  
target path.
Step 2. Remove the grounding from the near-end of the target cable/pipe.
Note: Never connect or disconnect the...

Page 36

 36 78-9000-0192-2 Rev D
Step 12. Set the Frequency and Mode of the receiver.
a. Press  Freq [SK]
b.  Select the same frequency on the 
receiver that was selected on the 
transmitter by pressing Active  [SK 
Toggle].
c.  Press Menu/OK [5] to save the setting 
and return to Locate mode.
d.  Press  Mode  [SK Toggle] until Dir Pk  
is displayed.
Step 13.  Stand away from the suspected target path and adjust the Gain [3] down until 
the Bar Graph [11] ([10] for 2550 locator) opens completely.
Step 14.  Walk...

Page 37

78-9000-0192-2 Rev D 37
Step 18. Measure the Depth and Current occasionally to verify target path.
Note: In order to measure the Depth and Relative Current accurately, the operator 
must pinpoint the target pipe or cable, and the receiver handle should be in-line with 
the target path.  
− While in Dir Pk mode, find the highest Signal Strength [9] ([8] for 2550 
locator).
 
− Lower the tip of the receiver to the ground. Twist the receiver left and right 
while watching the Signal Strength [9] ([8] for...

Page 38

 38 78-9000-0192-2 Rev D
Step 8. With the receiver handle perpendicular to the conduit path, locate the ADP 
position by moving along the path until the strongest Signal Strength [9] ([8] 
for 2550 locator) is found. Adjust Gain [3] up or down when the Bar Graph 
[11] ([10] for 2550 locator) remains either fully open or fully closed.
Step 9.  Refer to the ADP operating instructions for further information.
A. Determining Active Duct Probe Depth
Step 1.  Place the tip of the receiver on the ground...

Page 39

78-9000-0192-2 Rev D 39
12. Locating Buried Sheath Faults And Earth 
Return Faults  
(3M™ Dynatel™ Models 2573 and 2573-iD only)
Note: Remove (disconnect) both the near-end and far-end grounding from the  
test section.
A.  Transmitter Setup
Note: Do not make any connections while the transmitter is on. Fault loc\
ation will not 
work unless the near-end and far-end grounds are disconnected.
Note: This method only works on direct buried cables/conductors. It will\
 not work if 
the cables/conductors are...

Page 40

 40 78-9000-0192-2 Rev D
B. Pinpointing the Buried Fault
Step 1.  Connect the 3M™ Earth Contact Frame to the External Jack [15] ([14] for 2550 
locator) of the receiver using the Earth Contact Frame cable (4 ft. (1.2 m) cable).
Step 2.  Press On/Off [1] to power on the receiver. The receiver display screen will 
display  “Fauly Calibrating” for about 5 seconds.
Step 3.  Press Menu/OK  [5].
Step 4.  Press Fault  [SK] to select Fault mode.
Step 5.  Hold the receiver in one hand and the Earth Contact Frame...