3D Perception CompactViewn Sx25+i User Manual
Have a look at the manual 3D Perception CompactViewn Sx25+i User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 21 3D Perception manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
3D perception COMPACTVIEW SX25+ Revision 3 User Manual 26 16.4 Set Up Sub-menu keystone V Adjust vertical keystone correction. Compensates fo r the geometrical distortion of the projected image resulting from tilting the projector to shoot highe r up on the wall. keystone H Adjust horizontal keystone correction. Compensates for the geometrical distortion of the projected ima ge resulting from shooting the image at an angle sideways on the screen. DPMS Activate/deactivate DPMS (Display Power Management Signaling). When DPMS is on, the projector will switch off following the powering of f or disconnection of the signal source. The projector w ill switch back on when the signal source is reactivate d. source scan Switches source scan on and off. With source scan on, the projector will search for another source if the current source is disconnected or switched off. With source scan off, the projector will remain at the selected source input even if the source is switche d off or disconnected. orientation Select between desktop front, desktop rear, ceiling front and ceiling rear mode. The image will be flipp ed and reversed accordingly. OSD Select the required position on the OSD (On Screen Display) language Select between languages RGB video Selects RGB video on the component video input (YPbPr). Requires composite sync connected to the composite video input. FOR ALL
3D perception COMPACTVIEW SX25+ Revision 3 User Manual 27 16.5 Utilities Sub-menu FOR ALL information Displays information about the source and projector status OSD Turn the On Screen Display on (display) or off (hid e) during source scan. OSD timeout Defines how long OSD is displayed after last key action before it disappears from the screen. OSD background Select background mode, whether translucent or opaque. reset Resets the projector to its basic settings. All parameters available in the various menus are reset to their factory values. Note: Control mode will automatically be reset to RS232 even if the projector is a type SX25+I. A power cycle is needed for the projector to detect the presence of a GCM card and to select the RIMI mode lamp reset Reset lamp after lamp change. Do not reset lamp counter unless the lamp has been replaced with an original new lamp. service menu For service personnel only. A special service code is needed to access internal calibration controls and status information. Not accessible to the user. test image Applies a fixed test image for set-up purposes SYSTEM INFORMATION
3D perception COMPACTVIEW SX25+ Revision 3 User Manual 28 16.6 Control Sub-menu mode Selects between RS232, RIMI (internal) and LAN control modes. The projector can be controlled by only one of the modes at a time. When using the CompactView SX25+I the mode must be set to RIMI (Rich Media Interface). When a GCM has been installed, the projector will detect its presence after a power cycle and select RIMI. Note: Reset to factory default will automatically reset to RS232. RS232 address For use when daisy-chaining several units. Select auto or fixed address. Only one address scheme is allowed per daisy-chain. The auto address is allocated following the relative position in the da isy- chain. The fixed address is an absolute address. On ly unique fixed addresses are allowed. RS232 fixed Select a unique fixed address in the range availabl e. baudrate Selects between baud rates 4800, 9600 and 19200. A lower baud rate may be required in installations wi th long cable runs. FOR ALL
3D perception COMPACTVIEW SX25+ Revision 3 User Manual 29 17. MAINTENANCE The projector may from time to time require cleanin g. Never open the projector, as this will void any warranties. Refer all service and repair work t o qualified personnel. Only the exterior of the projector may be cleaned. Use a damp cloth. Make sure no liquids enter the inside of the projector Vacuum-clean all the air vents regularly to maintain sufficient air flow. The projection lens is sensitive to scratches. Use lens-cleaning tissue, available at all photographic shops when cleaning the projection lens. Use lens cap when not in use.
3D perception COMPACTVIEW SX25+ Revision 3 User Manual 30 18. LAMP REPLACEMENT The STATUS lamp on the keypad will turn red when th e lamp life expires. In addition, a message will appear on the screen; “LAMP LIFE TIME HAS EXPIRED! Please change lamp.” 18.1 Remove old lamp Change the lamp when its lifetime expires. Always replace the lamp with the same type and rating. Always disconnect the power cord and wait until the projector has cooled down (60 minutes) before opening the lamp cover. Release the screw (A). Remove the lamp cover (B). Release the 3 screws on the lamp house (C).
3D perception COMPACTVIEW SX25+ Revision 3 User Manual 31 Pull the handle (D). Remove the lamp house (E). 18.2 Insert New Lamp Replace the lamp house (E) Fold the handle (D) back in to place. Tighten the 3 screws (C)
3D perception COMPACTVIEW SX25+ Revision 3 User Manual 32 Replace the lamp cover (B) Tighten the screw (A). In the “utilities” sub menu, reset the lamp timer.
3D perception COMPACTVIEW SX25+ Revision 3 User Manual 33 19. SERVICE INFORMATION This product contains no user-serviceable parts. If the product fails to function as expected, first check that all connections are properly made, and that the power cord is properly connected. Check that the projector and the video and computer sources are all switched on. Cables and cords may break over time. Try changing the cables and cords in case there is a bad or intermittent connection. Check if the circuit breaker or the fuse of the mai ns is intact. In the event of product failure, please contact you r reseller. You should prepare a description of the symptoms of failure you experience. Also state the projector number and serial number as printed on the label on the bottom of the projector .
3D perception COMPACTVIEW SX25+ Revision 3 User Manual 34 20. TECHNICAL DATA 20.1 Projector Specifications Resolution 1400 x 1050 (native) SXGA+ Display technology Single chip DLP™ technology by Texas Instruments® Display device LVDS DMD™ with DarkChip2™ technology Computer Compatibility UXGA, SXGA+, SXGA, XGA, SVGA, VGA PC, MAC, SGI and other workstations RGBHV, RGBS, RGsB Video Compatibility HDTV (1080i, 720p, 576i/p, 480i/p) NTSC, NTSC 4.43, PAL, PAL-M, PAL-N, SECAM. Faroudja™ de-interlacing with automatic film mode detection (3 : 2 and 2 : 2 pull -down) Aspect ratio 4 : 3 (native), 16 : 9 / 5 : 4 (compatible) Bandwidth Up to 205 MHz on analog RGB Up to 160 MHz on DVI Up to 75 MHz on component input Brightness Up to 2500 lumen Contrast Up to 2500 : 1 Wide angle lens f = 19.5 F = 2.8 throw ratio = 1 : 1 (distance : width) throw distance = 1.5m - 20m / 5 - 66 ft. Image width = 1.5m - 20m / 2.3 - 66 ft. offset = 108% Zoom lens f = 33 - 42 F = 2.75 - 3.1 Zoom factor = x 1.25 throw ratio = 1.70 - 2.2 : 1 (distance : width) throw distance = 1.5m -10m / 5 - 33 ft. image width = 0.7m - 5.7m / 2.3 - 18.8 ft. offset = 108% Lamp 250W UHP™ dimmable to 200W Lamp life 2000 hrs (typ) to 50% brightness @ 250W 4000 hrs (typ) to 50% brightness @ 200W Noise level 28 dB (typ), 32 dB (max) @ 20°C/68°F, sea level Dimensions 244 x 278 x 88 mm / 9.6 x 10.9 x 3.5, excluding len s Weight 3.4 kg / 7.5 lbs
3D perception COMPACTVIEW SX25+ Revision 3 User Manual 35 Inputs 2 VGA 15 pin female HD-DSUB analog RGBHV 1 DVI-D female digital RGB 1 Component video female 3 x RCA/phono 1 S-video female 4 pin mini-DIN 1 C-video female RCA/phono 2 Audio 3.5 mm female stereo jack 1 RS 232 9 pin female DSUB (control, firmware updat e) 1 USB-B female (control, firmware update) 1 LAN RJ-45 female (control, firmware update) 1 Remote Control 3.5 mm female stereo jack Outputs 1 VGA Monitor 15 pin female HD-DSUB analog RGBHV 1 Audio 3.5 mm female stereo jack 1 RS 232 9 pin male DSUB Power 90-260 VAC, 50-60 Hz, 350W Conformance CE, FCC A, CSA(C,US) Temperature operating 0-40°C / 32-104°F, 0-1500 m / 0-4950 ft 0-35°C / 32-95°F, 1500-3000 m / 4950-9900 ft Temperature storage -20 - 60°C / -4 - 140°F Humidity operating 20-90% RH, non-condensing Humidity storage 10-95% RH, non-condensing 20.2 GCM Specifications These specifications apply to the CompactView SX25+ I only Non-linear image mapping from 50% to 200 % Total latency typically 250 line period Automatic and manual options Up to 100 geometrical control points (compliant wit h curved screens requirements) Warping Up to 5th order approximation between geometrical c ontrol points Multisided non-linear blending from 2% to 100% of total image Alpha adjustable from 0 to 4 across overlapped area s Gamma adjustable from 0.25 to 4 in overlapped areas Soft Edge Blending Up to 5 geometrical control points (compliant with curved screens requirements) Individual RGB adjustments of ± 20% in addition to native adjustment capabilities Primary Colour Calibration (For ‘E’ models with Com pactUTM zer0 only) Colour Input Offset and Input Gain adjustments Gamma Individual RGB adjustments from 0.25 to 4 in addition to native adjustment capabilities Specifications are subject to change without prior notice. All values may vary up to +/- 20%.