                                                    1 
PG21 Series 
Pilfergard Door Alarms 
 
INSTALLATION INSTRUCTIONS 
WI738F  1/06 
345 Bayview Avenue 
Amityville, New York 11701 
For Sales and Repairs, (800) 645-9445 
For Technical Service, (800) 645-9440 
© ALARM LOCK 2006 
AL ARM LOCK 
DESCRIPTION 
The PG21 is a microprocessor-controlled door alarm for sur-
face mounting on a door or door frame.  Typical applications 
include emergency fire escape doors, nursing home stairwell 
doors, rear restaurant and theater doors.  The PG21 is de-
signed to...
                                            
                                                    IMPORTANT 
 
Templates must be printed without size modifications 
and verified for dimensional accuracy. 
 
•Before printing, select the printing options necessary 
to ensure that copies are produced without size  
adjustments.  
 
•After printing, measure the dimensions indicated on 
the template to ensure correct scale.  
                                            
                                                    CYLINDER ADAPTER KIT 
 
ADDENDUM 
WI 1177  1/03 
CAUTION 
PROPER ALIGNMENT OF GEARS IS CRITICAL! 
 
FAILURE TO ALIGN GEARS PROPERLY WILL CAUSE LOCK TO MALFUNCTION.   
345 Bayview Avenue 
Amityville, New York 11701 
For Sales and Repairs 1-800-ALA-LOCK 
For Technical Service 1-800-645-9440 
© ALARM LOCK 2003 
Note:  See the illustrated instructions, WI 1163, 
How to Replace Cylinder for detailed replace-
ment procedures.  After inserting the new cylin-
der and Slide Plate, and before replacing the 
Cover...
                                            
                                                    1 
  To run DL-Windows in XP Compatibility Mode, proceed as follows: 
 
1.     Locate the DL-Windows working directory--usually C:\DL-Windows. 
 
2.       Right-click DLWIN32.exe and click Properties.  Note:  Windows may display the file name as DLWIN32, as shown 
in the following image: 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
3.     In the Compatibility tab, check Run this program in compatibility mode for and select Windows XP (Service 
Pack 2) from the pull-down list.  Click OK to save your...
                                            
                                                    1 
Turn off User Access Control (UAC) in Windows® Vista as follows: 
 
Important:  If DL-Windows is installed, uninstall DL-Windows first, then reinstall after UAC is turned off. 
 
1.    Open the Windows
® Control Panel.   
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
2.    Open User Accounts.   
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
3.    Click Turn User Account Control on or off. 
 
 
 
 
WI1787  9/08 
345 Bayview Avenue 
Amityville, New York 11701 
For Sales and Repairs 1-800-ALA-LOCK 
For Technical Service...
                                            
                                                    Introduction 
The AL-IR1 is optically linked to the T3/T3E Series Locks via 
infrared light.  It is used for reading the various reports main-
tained by the locks, including the Audit Log. 
 
Specifications 
•Dimensions:  3½ W x 7L 
•Interface:  Infrared Light Beam 
•Activation:  Refer to Lock Instructions 
•Distance:  1 to 4 above the infrared LED 
•Controls:  3 (Power On/Off, printer Contrast and Paper Feed) 
•Paper:  Uses common 2¼ thermal paper available at most 
office supply stores (supplied)...
                                            
                                                    16.   Make sure the Battery Connec-
tor Wire is routed through the 
correct hole to meet up with the 
center oval hole drilled in step 10. 
INSIDE BATTERY KIT  
INSTALLATION INSTRUCTIONS 
WI1516  2/06 
345 Bayview Avenue 
Amityville, New York 11701 
For Sales and Repairs 1-800-ALA-LOCK 
For Technical Service 1-800-645-9440 
© ALARM LOCK 2006      Publicly traded on NASDAQ  Symbol: NSSC      www.alarmlock.com 
7. Secure the Bat-
tery Mounting 
Bracket using the 
top door mount-
ing screw that is 
located...
                                            
                                                    1 
A-100 
INDOOR STAINLESS STEEL KEYPAD  
WIRING & PROGRAMMING INSTRUCTIONS 
WI1495  7/06 
GENERAL DESCRIPTION 
The A-100 is a self-contained access control keypad de-
signed for indoor basic access applications.  Its heavy 
stainless steel faceplate is designed to mount on a standard 
single-gang electrical box.  The A-100 operates up to three 
outputs (two relays and 1 open-collector transistor) and can 
be used to trigger a door strike, an electromagnetic door 
lock, or any other relay-activated...
                                            
                                                    1 
A-100IMWP 
ILLUMINATED MULLION KEYPAD  
WIRING & PROGRAMMING INSTRUCTIONS 
WI1497  7/06 
GENERAL DESCRIPTION 
The A-100IMWP is a self-contained access control keypad 
designed outdoor applications.  Its heavy stainless steel mul-
lion-style surface mount enclosure is designed to be used in 
narrow stile applications.  The A-100IMWP operates up to 
three outputs (two relays and 1 open-collector transistor) 
and can be used to trigger a door strike, an electromagnetic 
door lock, or any other...
                                            
                                                    1 
A-100WP 
SEALED ENVIRONMENT KEYPAD  
WIRING & PROGRAMMING INSTRUCTIONS 
WI1496  12/06 
GENERAL DESCRIPTION 
The A-100WP is a self-contained access control keypad de-
signed for the harshest outdoor environments.  Its heavy 
stainless steel enclosure and metal keypad buttons also 
make it extremely vandal resistant.  The A-100WP operates 
up to three outputs (two relays and 1 open-collector transis-
tor) and can be used to trigger a door strike, an electromag-
netic door lock, or any other...
                                            
                                                    IMPORTANT 
 
Templates must be printed without size modifications 
and verified for dimensional accuracy. 
 
•Before printing, select the printing options necessary 
to ensure that copies are produced without size  
adjustments.  
 
•After printing, measure the dimensions indicated on 
the template to ensure correct scale.  
                                            
                                                    ADDENDUM  
LEVER CONNECTOR REPLACEMENT KIT  
WI1454  8/05 
345 Bayview Avenue 
Amityville, New York 11701 
For Sales and Repairs 1-800-ALA-LOCK 
For Technical Service 1-800-645-9440 
Publicly traded on NASDAQ    Symbol: NSSC 
© ALARM LOCK 2005 
HOW TO REPLACE THE LEVER CONNECTOR (NEW PART HW572E) 
2.     Remove the Lever Handle 
Spring (HW1220) and set aside. 1.    With housing removed from door, 
unscrew two screws and remove 
the Spring Cover Plate (HW565) as 
shown.   3.   Remove Connector Plate...
                                            
                                                     
LEVER RETURN SPRING REPLACEMENT KIT  
WI1498  3/06 © ALARM LOCK 2006      Publicly traded on NASDAQ  Symbol: NSSC      www.alarmlock.com 
2.    Remove the Spindle Bushing 
Assembly and set aside.  Remove 
Locking Piece (and the small spring 
attached to it).   1.     With outside housing removed 
from door, unscrew eight screws 
and remove the Rear Cover 
Plate as shown.   3.  Remove Slide Plate.  Remove Slide 
Plate Springs. 4.  Remove the 3 screws that hold 
down the Plastic Cover Plate. 