    							11 APPENDIX A
    CMOS RAM Data Test Protocol
    The first sub-test of the CMOS RAM
    data is that of the ATTRACT MODE
    MESSAGE checksum.  If the test does
    not pass, the factory ATTRACT MODE
    MESSAGE is restored.  Next, the game
    adjustments are checked and restored to
    factory settings if an error is found.  If
    game adjustments are found intact, the
    high score table is checked for any bad
    entries.  Bad entries are replaced with a
    score of 4,000 points and no initials.  If
    all entries check, the game returns to the
    Game Over Mode.
    If game adjustments are restored to
    factory settings, the AUDIT TOTALS
    are checked.  If 5 or more audit digits
    are other than 0-9 (that is hexadecimal
    A through F) all audit totals are cleared.
    This is followed by a check of the high
    score table and the table is reset to
    factory settings if errors are found.
    Finally, game adjustments are rechecked
    and either OPEN COIN DOOR or
    FACTORY SETTINGS RESTORED is
    displayed.  With the former, open the
    coin door and turn the game OFF and
    ON and then FACTORY SETTINGS
    RESTORED will be displayed.  Return
    to game over by depressing the
    ADVANCE pushbutton or by turning
    the game OFF and ON a second time.
    “Warning: This equipment generates, uses, and can radiate radio frequency energy and if
    not installed and used in accordance with the instructions manual, may cause interference
    to radio communications. As temporarily permitted by regulation it has not been tested
    for compliance pursuant to Subpart J of Part 15 of FCC Rules, which are designed to
    provide reasonable protection against such interference. Operation of this equipment in a
    residential area is likely to cause interference in which case the user at his own expense
    will be required to take whatever measures may be required to correct the interference.”
    POWER  ON
    ATTRACT MODE
    MESSAGE?
    RESTORE
    FACTORY
    MESSAGE
    GAME
    ADJUSTMENTS?
    RESTORE
    FACTORY
    SETTINGS
    AUDITS?
    CLEAR
    AUDITS
    HIGH
    SCORE
    TABLE?
    RESET HIGH
    SCORE TABLE
    TO FACOTRY
    SETTINGS
    GAME
    ADJUSTMENTS?
    OPEN COIN DOOR
    DISPLAYED
    OPEN COIN
    DOOR
    POWER OFF
    AND ON
    FACTORY
    SETTINGS
    RESTORED
    DISPLAYED
    POWER ON
    AND OFF
    HIGH
    SCORE
    ENTRIES?
    BAD ENTRIES
    REPLACED WITH
    4,000 AND  NO
    INITIALS
    INITIAL TESTS
    INDICATE ALL
    SYSTEMS GO
    DISPLAYED
    1
    11
    PASS
    FAIL
    PASS
    FAIL
    PASS
    FAIL
    PASS
    FAIL
    5 OR MORE HEX A-F
    PASS
    FAIL
    PASS
    FAIL 
    						
    All Williams manuals Comments (0)