Feature Package 3 TRIAD-S, 1/2/3 Pocket Guide a new dimension in business communications 8051-00
STATION NUMBERING PLAN Feature Code Feature Code 911 Attendant Alert 608 ICLID Unanswered Call 635 Account Code 570 Internal Page Zone 1 - 8, All 701 - 709 Account Code (Enter) 627 Intercom Button 645 ACD Calls In Queue 579 + aaa Keyset Mode 648 +[#, 6] ACD Group 1 - 16 550 - 565 LCR 800 ACD Group Status 567 + aaa Loop 89 ACD Help 574 Mailbox Button 644 ACD Member Display 573 Meet Me Page 770 ACD Primary Login 572 + aaa Message Preselect 633 + mm ACD Primary Logout 571 Message Wait 623 ACD Secondary Login 582 + aaa Modem 499 ACD Secondary Logout 581 + aaa MPB Version 605 ACD Supervisor Display 577 + aaa Mute 629 ACD Supervisor Login 576 + aaa Night Service 604 ACD Supervisor Logout 575 + aaa Off-Net Forward 603 ACD/UCD Avail/Unavail 566 OHVO 628 All Call Page 700 One Touch Record 649 + 44v Answering Machine Ring 654 + 0 Overflow Avail/Unail 578 Answering Machine Speaker 654 + 1 Pause/Resume Rec 655 Attendant Clear Alarm 606 Personal Park 438 Attendant Disable CO Line 602 Pickup Park Group 1 - 8 #430 - #437 Attendant Unavailable 607 Pool 01 - 23 801 - 823 Attendant Override 601 Pool All 824 Background Music 632 Prime Key 691 Call Back 622 Release 641 Call Coverage 647 + xxx Remote Call Forward 642 Call Coverage Ring 646 + xxx Repeat Redial 643 Call Factor 580 Set Clock 692 Call Forward 640 SLT Call Pickup # 1 Call Forward Override 5 # SLT Call Back 663 Call Park Group 1 - 8 430 - 437 SLT Conf Park 664 Camp On 620 SLT Speed Dial 668 Cancel LCR Que 626 SLT Speed Programming 661 Clear Forward, DND, Message 662 Speed Directory 693 Clear VM Alarm 656 Station Call Park 439 CO Line (001-012) 88 + LLL Station Name 690 CO Line Queue 621 Station Park Pickup # 6 Conference 624 Station - Tri ad S100 - 131 Custom Message 694 + xxx Station - Tri ad 1 /2100 - 171 Dial By Name 6 6Station - Tri ad 3100 - 351 Directory Dial 680 Station Relocate 636 + xxx Distinctive Ring 695 Stop Trace 658 Do Not Disturb 631 Telecenter Adm 652 D T M F R e c e i v e r Te s t 6 5 7 Te l e c e n t e r E x t 6 5 0 Executive Override 625 Tone Ring 6# + xxx External Page Zone All, 1, 2 760 - 762 UCD Group 550 - 565 Flash 660 UNA/UDA #5 Group Call Pickup # 0 VM Group 1 - 8 440 - 447 Headset Mode 634 VM Message Cancel 421 HPT 667 VM Message Set 420 Hunt Group 1 - 8 450 - 457 VM Message Set w/Count 422 ICLID Answered Call 659 Volume 638 ICLID Name/Number 653 Xfer Unans CO Call 639 KSU 9-Pin Female 3 5 7 2 5 8 Tri ad 1/ 2 MPB and SIU Triad 3 MPB 1480-00 9-Pin Male Switch Settings 1 2 3 4 5 6 7 8 SW1 1 2 3 4 5 6 7 8 SW2 Up/On Dwn/Off CALLER ID CONNECTIONFLASH CODES Flash Code Feature Flexible Button 01 System Timers 1-20 02 Additional System Timers 1-6 05 System Features 1 Programming 1-13 06 System Features 2 Programming 1-13 07 Flash Rates (Programmable) 1-19 09 System Parameters Programming 13-18 10 Attendant Station Assignment 11 System Time and Date 1 12 PBX Dialing Codes 13 Executive/secretary Pairs 1-4 14 On Board Relay Programming 1-6 15 Baud Rate Assignments 1-4 16 Network Tables 20 Access Codes 1-2 21 Station Message Detail Recording 1-6 22 Weekly Night Mode Schedule 1-8 23 Directory Dialing 1-3 24 Cabinet/Card Programming 1-20 30 Hunt Groups 1-13 31 Verified Account Codes Table 1-4 39 CO Line Group Queuing 1-8 40 CO Programming - Page A - Btn 19 1-15 CO Programming - Page B - Btn 20 1-9 CO Programming - Page C - Btn 21 1-10 41 Miscellaneous CO Parameters - Btn 1 1-6 42 Flexible Port AssignmentTr iad 1 /2 Tr iad 31-6 1-8 43 ICLID Ringing Assignment(s) 1, 18-20 44 DID Programming 2-4 45 ISDN Programming (Triad 3)1-12/1-17 47 T-1 Alarm Programming 1-7, 11-16 50 Station Programming - Page A - Btn 19 1-18 Station Programming - Page B - Btn 20 1-14, 17 Station Programming - Page C - Btn 21 1-5 52 Flexible Numbering Assignment 55 Local Number/Name Translation Table 1-4 56 ICLID Features 1-4 60 ACD* Group Programming - Page A 1-14 UCD Group Programming - Page A 1-11 UCD Station Assignments - Page B 1–8 61 ACD* Timers 1-2, 5-7 62 ACD* RAN Announcement Tables* 1–8 63 ACD* Interface Trace 1-3 61 UCD Timers 1-6 62 UCD Announcement Tables (RAN) 1–8 65 Voice Mail Group Programming 1-12 66 Voice Mail Outpulsing Table 1-9 67 Voice Mail In-Band Features 1-3 68 Voice Mail Index Table 1-2 70 Exception Tables ( Toll Restn) Programming 1-12 75 LCR Tables Programming 1-8 80 Initialize Database Parameters 1-15, 20 85 Printing System Database Parameters 1-16 86 Load Database Routine 1-2 POINT-TO-POINT T-1 CONNECTION System 1 System 2 DA15 Female Pin # R1 1 -->
CKIB / CSIB WIRING (Triad-S) Pair Pin # Color 1 10026 1WH/BL BL/WH 2 10127 2WH/OR OR/WH 3 10228 3WH/GN GN/WH 4 10329 4WH/BN BN/WH 5 10430 5WH/SL SL/WH 6 10531 6RD/BL BL/RD 7 10632 7RD/OR OR/RD 8 10733 8RD/GN GN/RD 934 9RD/BN BN/RD 10 35 10RD/SL SL/RD 11 36 11BK/BL BL/BK 12 37 12BK/OR OR/BK 13 38 13BK/GN GN/BK 14 39 14BK/BN BN/BK 15 40 15BK/SL SL/BK 16 41 16YL/BL BL/YL 17 42 17YL/OR OR/YL 18 43 18YL/GN GN/YL 19 44 19YL/BN BN/YL 20 -T EXP1R45 20YL/SL SL/YL 21 - T MOH1R46 21VI/BL BL/VI 22 - T MOH2R47 22VI/OR OR/VI 23 - T Relay1R48 23VI/GN GN/VI 24 - T Relay2R49 24VI/BN BN/VI 25 50 25VI/SL SL/VIETIB WIRING Port # Pin # Color 126 1WH/BL BL/WH 27 2WH/OR OR/WH 228 3WH/GN GN/WH 29 4WH/BN BN/WH 330 5WH/SL SL/WH 31 6RD/BL BL/RD 432 7RD/OR OR/RD 33 8RD/GN GN/RD 534 9RD/BN BN/RD 35 10RD/SL SL/RD 636 11BK/BL BL/BK 37 12BK/OR OR/BK 738 13BK/GN GN/BK 39 14BK/BN BN/BK 840 15BK/SL SL/BK 41 16YL/BL BL/YL 942 17YL/OR OR/YL 43 18YL/GN GN/YL 1044 19YL/BN BN/YL 45 20YL/SL SL/YL 1146 21VI/BL BL/VI 47 22VI/OR OR/VI 1248 23VI/GN GN/VI 49 24VI/BN BN/VILCOB / GCOB/ DID WIRING Pair Pin # Color 1 - R CO1T26 1WH/BL BL/WH 2 - R CO2T27 2WH/OR OR/WH 3 - R CO3T28 3WH/GN GN/WH 4 - R CO4T29 4WH/BN BN/WH 5 - R CO5T30 5WH/SL SL/WH 6 - R CO6T31 6RD/BL BL/RD 7 - R CO7T32 7RD/OR OR/RD 8 - R CO8T33 8RD/GN GN/RD 934 9RD/BN BN/RD 10 35 10RD/SL SL/RD 11 36 11BK/BL BL/BK 12 37 12BK/OR OR/BK 13 38 13BK/GN GN/BK 14 39 14BK/BN BN/BK 15 40 15BK/SL SL/BK 16 41 16YL/BL BL/YL 17 42 17YL/OR OR/YL 18 43 18YL/GN GN/YL 19 44 19YL/BN BN/YL 20 45 20YL/SL SL/YL 21 46 21VI/BL BL/VI 22 47 22VI/OR OR/VI 23 48 23VI/GN GN/VI 24 49 24VI/BN BN/VI 25 50 25VI/SL SL/VIDTIB / DTIB-E / SLIB WIRING (Tr ia d 3) Pair Pin # Color 1 10026 1WH/BL BL/WH 2 10127 2WH/OR OR/WH 3 10228 3WH/GN GN/WH 4 10329 4WH/BN BN/WH 5 10430 5WH/SL SL/WH 6 10531 6RD/BL BL/RD 7 10632 7RD/OR OR/RD 8 10733 8RD/GN GN/RD 9 10834 9RD/BN BN/RD 10 10935 10RD/SL SL/RD 11 11036 11BK/BL BL/BK 12 11137 12BK/OR OR/BK 13 11238 13BK/GN GN/BK 14 11339 14BK/BN BN/BK 15 11440 15BK/SL SL/BK 16 11541 16YL/BL BL/YL 17 11642 17YL/OR OR/YL 18 11743 18YL/GN GN/YL 19 11844 19YL/BN BN/YL 20 11945 20YL/SL SL/YL 21 12046 21VI/BL BL/VI 22 12147 22VI/OR OR/VI 23 12248 23VI/GN GN/VI 24 12349 24VI/BN BN/VI 25 12450 25VI/SL SL/VIMISU WIRING Pair Pin # Color 1 - T Relay1R26 1WH/BL BL/WH 2 - T Relay2R27 2WH/OR OR/WH 3 - T Relay3R28 3WH/GN GN/WH 4 - T Relay4R29 4WH/BN BN/WH 5 - T Relay5R (Triad 3)30 5WH/SL SL/WH 6 - T Relay6R (Triad 3)31 6RD/BL BL/RD 732 7RD/OR OR/RD 833 8RD/GN GN/RD 934 9RD/BN BN/RD 10 35 10RD/SL SL/RD 11 - T MOH1R36 11BK/BL BL/BK 12 - T MOH2R37 12BK/OR OR/BK 13 - T EXP1R38 13BK/GN GN/BK 14 - T EXP2R39 14BK/BN BN/BK 15 40 15BK/SL SL/BK 16 41 16YL/BL BL/YL 17 42 17YL/OR OR/YL 18 43 18YL/GN GN/YL 19 44 19YL/BN BN/YL 20 45 20YL/SL SL/YL 21 46 21VI/BL BL/VI 22 47 22VI/OR OR/VI 23 48 23VI/GN GN/VI 24 49 24VI/BN BN/VI 25 50 25VI/SL SL/VI NOTES SYSTEM CAPACITY Tr ia d 1 Por ts CO/PBX/Centrex Lines DID Lines T-1 Trunks Tr ia d 2 Por ts CO/PBX/Centrex Lines DID Lines T-1 Trunk Stations Analog Stations Digital Telephones Single Line Telephones DTMF Receiver36 lines max. (6 per LCOB board) 24 lines max. (4 per DIDB board) -- DTMF or dial pulse signalling. 48 trunks max. (24 per T1IB board) 36 lines max. (6 per LCOB board) 36 lines max. (4 per DIDB board). DTMF or dial pulse signalling. 48 trunks max. (24 per T1IB board) 48 max. (12 per ETIB board) 60 max. (12/24 per DTIB board) 48 max. (6 per SLIB board) Each DTMF Receiver Module (DTRU) contains 2 DTMF receivers. The DTRU board mounts as a daughter board on the LCOB, DIDB, and SLIB. Each DTMF Receiver Module (DTMF-A) contains 4 DTMF receivers. The DTMF-A board mounts as a daughter board on the T1IB. Tr ia d 3 Por ts CO/PBX/Centrex Lines DID Lines T-1 Trunks ISDN Trunks Stations Analog Stations Digital Telephones Single Line Telephones DTMF Receiver112 max. (8 per LCOB/GCOB board) 96 max. (8 per DIDB. DTMF or dial pulse signalling) 144 max. (24 T-1 trunk circuits per T1IB board) 138 max. (23 trunks per PRIB board) 252 max. (12 per ETIB board) 252 max. (12/24 per DTIB board) 180 max. (12 per SLIB board) 26 max. (2 on MISU, 24 on peripheral boards) Each DTMF Receiver Unit (DTMF-A or DTMF-B) contains 4 DTMF receivers. --> DTMF-A board mounts as a daughter board on the T1IB, PRIB, and SLIB. --> DTMF-B board mounts as a daughter board on the LCOB/GCOB, DIDB. Tr ia d-S BKSU Capacity CO/PBX/Centrex Lines Stations Digital Telephones Single Line Telephones BKSU + EKSU Capacity CO/PBX/Centrex Lines Stations Digital Telephones Single Line Telephones DTMF Receiver6 lines max. 16 max. (16 per CKIB board) 8 max. (8 per CSIB board) 12 Lines max. 32 max. (8 per CKIB board) 24 max. (8 per CSIB board) (System maximum: 12 lines, 8 digital phones, 24 SLTs) Basic: 1 each With DTMF-A: 5 (provides 4 additional receivers) LCOB / SLIB WIRING (Triad 1/2) SLIB Connector SLIB Designation Connector Pin # M1 3 Tip 1 2Ring 1 4Tip 2 1Ring 2 M2 3 Tip 3 2Ring 3 4Tip 4 1Ring 4 M3 3 Tip 5 2Ring 5 4Tip 6 1Ring 6
Part Number Description DVXPlus II/III DVXPlus IV IN8003-00/8000-00 IN9000-00 Basic KSU IN8032-30 IN9032-00 Digital Interface Board (DTIB12) 12-cir IN8031-10 IN9031-10 Direct Inward Dial Board (DIDB) 8-cir IN9033-10 IN9033-10 DTMF Receiver Unit (DTMF-A) 4-cir IN8032-20 IN9032-20 Electronic Interface Board (ETIB) 12-cir IN8002-01 IN9002-01, 02* Expansion KSU (*10, 6- slot) IN8031-00 IN9031-00 Loop Start CO Board (LCOB) 8-cir IN8030-01 IN9030-01 Master Processor Board (MPB) IN8030-20 IN9030-20 Memory Expansion Unit (MEMU) IN8035-00 IN9035-00 Misc Interface Service Unit (MISU) IN8030-40 IN9030-40 Phase-Lock-Loop Unit (PLLU) IN8036-00 IN9036-00 Power Failure Transfer Unit (PFTU) 6-cir IN8071-20 (250-w) IN9071-10, 15 Power Supply - 10, 15 amp IN8073-00 IN9073-00 Ring Generator Unit (RGU) IN8033-00 (6-cir) IN9033-00 Single Interface Board (SLIB) 12 cir IN8031-31 IN9031-31 T-1 Trunk Board ( T1IB) 24-cir IN9074-00 DC/DC Converter Unit (DCCU) IN9032-10 Digtl Interface Board Expnsn (DTIB-E) 12-cir IN9031-01 DTMF Receiver Unit (DTMF-B) 4-cir IN9031-50 Ground Start CO Board (GCOB) 8-cir IN9033-20 Message Wait Unit (MSG12) IN9030-10 Program Module Unit (PMU) IN9030-30 Serial Interface Unit (SIU-2) IN8030-30 2400 Baud Modem (MODU) IN8032-40 Digital Interface Board (DTIB24) 24-cir IN8031-50 DTMF Receiver Unit (DTRU) 2-cir IN8033-10 Message Wait Unit (MSGU) IN8035-10 Serial Interface Unit (SIU) IN9011-XX Basic Key Telephone IN9013-XX Enhanced Key Telephone IN9015-XX Executive Key Telephone IN9016-71 Elite Large Screen Key Telephone IN9010-XX DSS Console IN9854-00 Single Line Adapter IN9020-00 CTI Connector Box IN1440-00 / IN1480-00 Caller ID Unit ( TCI) 4, 8-port XXX denotes color option: 71 = Charcoal, 08 = Off-White