- 31 – ViewSonic Corporation Confidential - Do Not Cop VA1903wb/VA1903wm Black-White Pattern (Figure 9) 4.3 Function Test and Alignment Procedure All Modes Reset You should do “All Mode Reset” (Refer to Chapter III-3. Hot Keys for Function Controls) first. This action will allow you to erase all end-user’s settings and restore the factory defaults. Auto Image Adjust Please select and enter “Auto Image Adjust” function on Main Menu to see if it is workable. The “Auto Image Adjust” function is aimed to offer a better screen quality by built-in ASIC. For optimum screen quality, the user has to adjust each function manually. Firmware Test Pattern: Burn In Mode (Refer to Chapter III-3. Hot Keys for Function Controls) - Make sure the F/W is the latest version. DDC Test Pattern: EDID program Make sure it can pass test program. Fine Tune and Sharpness Test Signal: 1440*900@60Hz Test Pattern: Line Moire Pattern Check and see if the image has noise and focus performs well. Eliminate visual line bar. If not, readjust by the following steps: (a)Select and enter “Fine Tune” function on “Manual Image Adjust” to adjust the image to eliminate visual wavy noise. (b)Then, select and enter “Sharpness” function to adjust the clarity and focus of the screen image. Boundary Test Signal: 1440*900@60Hz Test Pattern: Horizontal & Vertical Line Thickness Pattern Check and see if the image boundary is within the screen frame. If not, readjust by the following steps: (a)Select and enter “Manual Image Adjust” function on OSD Main Menu. (b)Then, select and enter “Horizontal Size” or “Horizontal/Vertical Position” function to adjust the video boundary to be full scanned and within screen frame.
- 32 – ViewSonic Corporation Confidential - Do Not Cop VA1903wb/VA1903wm White Balance Test Signal: 1440*900@60Hz Test Pattern: White and Black Pattern 1.5.8 R, G, B, Colors Contrast Test Signal: 1440*900@60Hz Test Pattern: R, G, B, Color Intensities Pattern and 16 Gray Scale Pattern - Check and see if each color is normal and distinguishable. - If not, please return the unit to repair area. Screen Uniformity and Flicker Test Signal: 1440*900@60Hz Test Pattern: Full White Pattern - Check and see if it is in normal condition. 1.5.10 Dead Pixel and Line Test Signal: 1440*900@60Hz Test Pattern: Dark and White Screen Pattern - Check and see if there are dead pixels on LCD panel with shadow gauge and filter film. - The total numbers and distance of dead pixels should be compliant with the spec. Mura Test Pattern: White, RGB, Black, & Grey Test Tool: 10% ND Filter - Check if the Mura can pass 10% ND Filter. Audio Test Signal: Voice signal (optional, depend on model) Test Pattern: liberty - Make sure there is audio output. - Make sure that audio function (volume 80%) is working without noise and resonance. - Make sure that the sound of right and left speakers are in balance. Check for Secondary Display Modes Test Signal: Analog: 640*480@60/75Hz; 720*400@70Hz; 800*600@56/60/72/75Hz; 1024*768@60/70/72/75Hz; 1280*1024@60/75Hz 1440*900@60/75Hz - Normally when the primary mode 1440*900@60Hz is well adjusted and compliant with the specification, the secondary display modes will also be compliant with the spec. But we still have to check with the general test pattern to make sure every secondary is compliant with the specification. All Modes Reset After final QC step, we have to erase all saved changes again and restore the factory defaults. You should do “All Mode Reset” again. Power Off Monitor Turn off the monitor by pressing “Power” button. 5.6 Firmware Upgrade Procedure When you receive the returned monitor, please check whether the firmware version is
- 33 – ViewSonic Corporation Confidential - Do Not Cop VA1903wb/VA1903wm the latest. If not, please do the following procedures to upgrade it to the latest version. 1 Equipment Needed - VA1703W/VA1903W Monitor - Fixture for Firmware Upgrade - Power Adapter (P/N: 47.58201.001) *1 for Fixture - VGA Cable (P/N: 42.59901.003) *1(Pin 4, 11 should be connected to GND) - PC (Personal Computer) - LPT Cable (P/N: 42.59906.001) *1 - Firmware Upgrade Program - One additional monitor for checking the program execution 2 Setup Procedure 2.1 Connect P2 of Fixture with printer port of PC by LPT Cable. 2.2 Connect P1 of Fixture with VA1703W/VA1903W Monitor by VGA Cable. 2.3 Plug Power Adapter to Fixture. 2.4 Connect Power Cord to VA1703W/VA1903W Monitor. 2.5 Connect P3 to the Signal Generator (eg.Chroma2326) for verifying it after the operation being completed. 2.6 Connect PC to the additional monitor. VA1703W/VA1903W
- 34 – ViewSonic Corporation Confidential - Do Not Cop VA1903wb/VA1903wm 3 Firmware Upgrade Procedure Step 1. Let VA1703W/VA1903W set to be connected with AC cable and VGA cable. Step 2.Execute the MSstar ISP tool. Step 3. Click “Connect” button . (On this step, if the connection is successful, the “Device Type is ******(Flash Type)” Dialog will be showed. If not, the error dialog will be done.) P2:to LPT Cable JP1:to Power Adapter P1:to VGA Cable P3:to Signal Generator
- 35 – ViewSonic Corporation Confidential - Do Not Cop VA1903wb/VA1903wm Step 4. Click “Read” button. Select the object bincode on your corresponding directory. Step 5. Click “Auto” button. Be sure that function of Erase Device (File Area), Blank, Program and Verify is selected, then execute the flashing action by clicking the “Run” button.
- 36 – ViewSonic Corporation Confidential - Do Not Cop VA1903wb/VA1903wm Step 6. If the flashing F/W has been completed, “Verify Ok” message will be shown on the right TextBox. Step 7. Unplug and replug power cord of VA1703W/VA1903W set and then check the OSD operation and image on srceen. Step 8. At last, do “Memory Recall.”
- 37 – ViewSonic Corporation Confidential - Do Not Cop VA1903wb/VA1903wm 3.2 Setup Procedure 3.2.1 Connect P2 and monitor of Fixture with VGA ports of VA1703W/VA1903W by VGA Cable. 3.2.2 Connect P1 of Fixture with Printer port of PC by LPT Cable. 3.2.3 Plug Power Adapter to Fixture. 3.2.4 Connect Power Cord to VA1703W/VA1903W Monitor. 3.2.5 Connect PC to the additional monitor. 3.3 DDC Key In Procedure Sep1.Select and execute DDC Key In program JP1: Power Adapter P2: VGA Cable P1:to LTP Cable
- 38 – ViewSonic Corporation Confidential - Do Not Cop VA1903wb/VA1903wm
- 39 – ViewSonic Corporation Confidential - Do Not Cop VA1903wb/VA1903wm Sep2:Inpute the S/N and execute “Enter”
- 40 – ViewSonic Corporation Confidential - Do Not Cop VA1903wb/VA1903wm