    							ViewSonic  PJ1172 36
    Replacing The Lamp
    If the indicators or a message prompts you to replace the lamp, replace the lamp as soon 
    as possible.
    1Turn off the projector, and unplug the power cord. Allow the lamp bulb to cool for at least 
    45 minutes.
    2Contact your dealer to prepare a new lamp. Tell the dealer your lamp type number. If the 
    projector is mounted on the ceiling, or if the lamp has broken, also ask the dealer to 
    replace the lamp.
    In the case of replacement by yourself, 
    3After making sure that the projector has 
    cooled adequately, slide the knob of a lamp 
    cover lock as shown in the Figure.
    Then, one side of the lamp cover is raised. 
    Pull up the lamp cover and remove it, as 
    shown in the Figure.
    4Unscrew the 3 screws, and slowly pull out 
    the lamp by the handle. Becareful not to 
    touch the inside of the lamp case.
    5Insert the new lamp, and tighten the 3 
    screws firmly to lock it in place.
    6Interlock the 2 tabs of the lamp cover to the 
    projector, put the lamp cover on the 
    projector.
    Then push the point of the lamp cover to 
    secure it, as shown in the figure. Make sure 
    that the lamp cover doesn’t come up.
    7Turn on the projector power, and reset the 
    lamp timer.
    (1) While the projector running, press the 
    MENU button to open the menu.
    (2) Choose the “OPTION” on the menu using the S/T button, then press the X button 
    or ENTER button.
    (3) Choose the “LAMP TIME” using the S/T button, then press and hold the RESET 
    button for 3 seconds.
    (4) Choose the “RESET” using the S button.
    memo Incorrectly resetting of the lamp timer (resetting without replacement, or neglect of 
    resetting after replacement) will result in incorrect message functions.
    Lamp cover knob Lamp cover
    Screws
    Ta b s 
    						
    							ViewSonic  PJ1172 37
    Air Filter
    Caring For The Air Filter
    The air filter should be cleaned about every 100 hours. If the indicators or a message 
    prompts you to clean the air filter, clean the air filter as soon as possible. If the soiling will 
    not come off the air filter, or it becomes damaged, then it needs to be replaced. Please 
    replace the air filter as soon as possible.
    memo When you replace the lamp, please replace also the air filter.
    1Turn off the projector, and unplug the power cord. Allow the lamp bulb to cool for at least 
    45 minutes.
    2After making sure that the projector has 
    cooled adequately, remove the filter cover 
    and the air filter.
    3Apply a vacuum cleaner to the filter cover and 
    the air filter to clean.
    If the soiling will not come off the air filter, or it 
    becomes damaged, it needs to be replaced.
    If the air filter needs to be replaced, contact 
    your dealer to prepare a new air filter. Tell the 
    dealer your air filter type.
    4Insert the cleaned air filter or a new air filter 
    and replace the filter cover.
    5Turn on the projector power and reset the 
    filter timer.
    (1) While the projector is running, press the 
    MENU button to open the menu.
    (2) Choose the “OPTION” on the menu using 
    the S/T button, then press the X button 
    or ENTER button.
    (3) Choose the “FILTER TIME” using the S/
    T button, then press and hold the RESET button for 3 seconds.
    (4) Choose the “RESET” using the S button.
    memo Incorrectly resetting the filter timer (resetting without replacement, or neglect of 
    resetting after replacement) will result in incorrect message functions.
     WA R N I N G
    • Please carefully read the “Quick Start Guide”.
    • Before caring the air filter, make sure the power switch is off and the power cable is not 
    plugged in, then to replacing wait at least 45 minutes for the lamp to cool sufficiently.
    • Use only the air filter of the specified type. Please call ViewSonic Tech Support for P/N.
    • Do not use the projector with the air filter and filter cover removed. The use without the 
    air filter could result in damage.
     CAUTION
    • If the air filter becomes clogged by dust or the like, internal temperature rises and could 
    cause malfunction. The power is automatically turned off in order to prevent the 
    projector from overheating internally.
    Hold the release but-
    tons of the filter cover
    while pulling it down.
    Hold the release but-
    ton of the air filter
    while pulling it out. 
    						
    							ViewSonic  PJ1172 38
    Other Care
    Caring For The Inside Of The Projector
    In order to ensure the safe use of your projector, please have it cleaned and inspected by 
    your local dealer about once every 2 years.
    Caring For The Lens
    1Turn off the projector, and unplug the power cord.
    2Lightly wipe the lens with a commercially available lens-cleaning wipe. Do not touch the 
    lens directly with your hand.
    Caring For The Cabinet And Remote Control
    1Turn off the projector, and unplug the power cord.
    2Wipe lightly with gauze or a soft cloth.
    memo If soiling is severe, dip soft cloth in water or a neutral cleaner dilute in water, and 
    wipe lightly after wringing well. Then, wipe lightly with a soft, dry cloth.
     WA R N I N G
    • Please carefully read the “Quick Start Guide”.
    • Before caring the air filter, make sure the power switch is off and the power cable is not 
    plugged in.
    • Be cautious of high temperature. Do not touch about the lens and ventilation openings 
    during use or immediately after use prevent a burn.
    • Never try to care for the inside of the unit yourself. Doing so is dangerous.
     CAUTION
    In correct care could have adverse influence such as coloration, peeling paint, etc.
    • Do not use cleaner or chemicals other than those listed below, including benzene and 
    paint thinner.
    • Do not use aerosols or sprays.
    • Do not polish or wipe with hard objects. 
    						
    							ViewSonic  PJ1172 39
    Troubleshooting
    Related Messages
    When the projector power is on, messages such as those shown below may be displayed. 
    When any such message is displayed on the screen, please respond as described below. If 
    the same mess age is displayed after the treatment, or if a message other than the 
    following appears, please contact your dealer or service company.
    memo Although these messages will be automatically disappeared around several minutes, it 
    will be reappeared every time the power is turned on.
    Message Description
    To maximize performance, 
    lamp replacement is 
    recommended.After the lamp running reaches 2000 hours, the 
    warning message is displayed, but it won’t 
    shut the unit off. The message display for 30 
    seconds when the PJ is turned on. If we push any 
    button while displaying the message, the message 
    disappear.
    CLEAN THE AIR FILTER
    POWER OFF FIRST, THEN CLEAN 
    THE AIR FILTER. AFTER 
    CLEANING THE AIR FILTER, 
    RESET THE FILTER TIMER.The time the filter timer has counted has 
    reached 100 hours.
    Please clear or change the air filter by referring to 
    the section “Air Filter”. After caring for the air filter, 
    please be sure to reset the filter timer.
    There is no input signal.
    Please confirm the signal input connection, and 
    the status of the signal source.
    The horizontal or vertical wavelength of the 
    inputted signal is outside of the response 
    parameters of this unit.
    Please confirm the specs for this unit or the signal 
    source specs. 
    						
    							ViewSonic  PJ1172 40
    Regarding The Indicator Lamps
    Lighting and blinking of the STANDBY/ON indicator, the LAMP indicator and the TEMP 
    indicator have the meanings as described in the table below. Please respond in according 
    with the instructions within the table. If the same indication is displayed after the treatment, 
    or if an indication other than the following is displayed, please contact your dealer or 
    service company.
    NOTE
    • When the interior portion has become overheated, for safety purposes, the power 
    source is automatically turned off, and the indicator lamps may also be turned off. In 
    such a case, press the [O] (Off) side of the main power switch, and wait at least 
    45minutes. After the projector has sufficiently cooled down, please make confirmation of 
    the attachment state of the lamp and lamp cover, and then turn the power on again.
    (This table is continued to the following page.) STANDBY/
    ON indicatorLAMP 
    indicatorTEMP 
    indicatorDescription
    Lighting in 
    OrangeTurned offTurned offThe projector is in a standby state.
    Please refer to the section “Power On/Off”.
    Blinking in 
    GreenTurned offTurned offThe projector is warming up.
    Please wait.
    Lighting in 
    GreenTurned offTurned offThe projector is in an on state.
    Ordinary operations may be performed.
    Blinking in 
    OrangeTurned offTurned offThe projector is cooling down.
    Please wait.
    Blinking in 
    Red(discretion-
    ary)(discretion-
    ary)The projector is cooling down. A certain error 
    has been detected.
    Please wait until the STANDBY/ON indicator fin-
    ishes blink, and then perform the proper response 
    measure using the item descriptions below as ref-
    erence.
    Lighting in 
    RedLighting in 
    RedTurned offThe lamp does not light, and there is a 
    possibility that interior portion has become 
    heated.
    Please turn the power off, and allow the unit to 
    cool down at least 20 minutes. After the projector 
    has sufficiently cooled down, please make 
    confirmation of the following items, and then turn 
    the power on again.
    • Is there blockage of the air passage aperture?
    • Is the air filter dirty?
    • Does the peripheral temperature exceed 35°C?
    If the same indication is displayed after the 
    treatment, please change the lamp by referring to 
    the section “Lamp”. 
    						
    							ViewSonic  PJ1172 41
    Regarding The Indicator Lamps (continued)
    STANDBY/
    ON indicatorLAMP 
    indicatorTEMP 
    indicatorDescription
    Lighting in 
    RedBlinking in 
    RedTurned offEither there is no lamp and/or lamp cover, or 
    either of these has not been properly fixed.
    Please turn the power off, and allow the unit to 
    cool down at least 45 minutes. After the projector 
    has sufficiently cooled down, please make confir-
    mation of the attachment state of the lamp and 
    lamp cover, and then turn the power on again.
    If the same indication is displayed after the treat-
    ment, please contact your dealer or service com-
    pany.
    Lighting in 
    RedTurned offBlinking in 
    RedThe cooling fan is not operating.
    Please turn the power off, and allow the unit to 
    cool down at least 20 minutes. After the projector 
    has sufficiently cooled down, please make confir-
    mation that no foreign matter has become caught 
    in the fan, etc., and then turn the power on again.
    If the same indication is displayed after the treat-
    ment, please contact your dealer or service com-
    pany.
    Lighting in 
    RedTurned offLighting in 
    RedThere is a possibility that interior portion has 
    become heated.
    Please turn the power off, and allow the unit to 
    cool down at least 20 minutes. After the projector 
    has sufficiently cooled down, please make confir-
    mation of the following items, and then turn the 
    power on again.
    • Is there blockage of the air passage aperture?
    • Is the air filter dirty?
    • Does the peripheral temperature exceed 35°C?
    If the same indication is displayed after the treat-
    ment, please change the lamp by referring to the 
    section “Lamp”.
    Lighting in 
    GreenAlternative Blinking in 
    RedThere is a possibility that interior portion has 
    become overcooled.
    Please use the projector within the usage temper-
    ature parameters (0°C to 35°C). After the treat-
    ment, resent the power to on.
    Lighting in 
    GreenSimultaneous Blinking 
    in RedIt is time to clean the air filter, or there is no air 
    filter.
    Please immediately turn the power off, and clean 
    or change the air filter by referring to the section 
    “Air Filter”. After cleaning or changing the air filter, 
    please be sure to reset the filter time. After the 
    treatment, resent the power to on. 
    						
    							ViewSonic  PJ1172 42
    Phenomena That May Easily Be Mistaken For Machine 
    Defects
    Before requesting repair, please check in accordance with the following chart. If the 
    situation cannot be corrected, please contact your dealer or service company.
    NOTE
    • Although bright spots or dark spots may appear on the screen, this is a unique 
    characteristic of liquid crystal displays, and such do not constitute or imply a machine 
    defect.
    (This table is continued to the following page.)
     WA R N I N G
    Never use the projector if abnormal operations such as smoke, strange odor, excessive 
    sound, damaged casing or elements or cables, penetration of liquid or foreign matter, etc. 
    should occur. In such cases, immediately turn off the power switch and then disconnect 
    the power plug from the power outlet After making sure that the smoke or odor has 
    stopped, contact your dealer or service company.
    Phenomenon Cases not involving a machine defectReference 
    page(s)
    Power does not 
    come onThe power cord is not plugged in.
    Correctly connect the power cord.
    9
    The power switch is not set to the on position.
    Set the power switch to [ | ] (On).13
    The main power source has been interrupted during opera-
    tion such as by a power outage (blackout), etc.
    Please turn the power off, and allow the unit to cool down at 
    least 20 minutes. After the projector has sufficiently cooled 
    down, please turn the power on again.
    13
    Either there is no lamp and/or lamp cover, or either of these 
    has not been properly fixed.
    Please turn the power off, and allow the unit to cool down at 
    least 45 minutes. After the projector has sufficiently cooled 
    down, please make confirmation of the attachment state of the 
    lamp and lamp cover, and then turn the power on again.
    35, 36
    Neither sounds 
    nor pictures are 
    outputted.The signal cables are not correctly connected.
    Correctly connect the connection cables.
    6, 7, 8
    Signal source does not correctly work.
    Correctly set up the signal source device by referring to the 
    manual of the source device.
    6, 7, 8
    The input changeover settings are mismatched.
    Select the input signal, and correct the settings.14 
    						
    							ViewSonic  PJ1172 43
    Phenomena That May Easily Be Mistaken For Machine Defects (continued)
    Phenomenon Cases not involving a machine defectReference 
    page(s)
    Pictures are dis-
    played, but no 
    sounds are 
    heard.The signal cables are not correctly connected.
    Correctly connect the connection cables.
    6, 7, 8
    The volume is adjusted to an extremely low level.
    Adjust the VOLUME to a higher level.17, 31
    The sound is muted.
    Press the MUTE button to restore the sound.17
    The audio input is not correctly selected when the child 
    window is displayed.
    Correctly select the audio input.
    20
    Sounds are 
    heard, but no 
    pictures are 
    displayed.The lens cap is attached.
    Remove the lens cap.
    2
    The signal cables are not correctly connected.
    Correctly connect the connection cables.6, 7, 8
    The brightness is adjusted to an extremely low level.
    Adjust the BRIGHT to a higher level using the menu function.21
    The screen is blanked.
    Press the BLANK button to return to the input signal screen.17
    Colors have a 
    faded-out 
    appearance, or 
    color tone is poor.Color settings are not correctly adjusted.
    Perform picture adjustments by changing the COLOR BAL R, 
    COLOR BAL G, COLOR BAL B, COLOR and/or TINT settings, 
    using the menu functions.
    22
    Pictures appear 
    dark.The brightness and/or contrast are adjusted to an 
    extremely low level.
    Adjust the BRIGHT and/or CONTRAST settings to a higher 
    level using the menu function.
    21
    The WHISPER function is working.
    Select the NOR MAL to the item WHISPER in the MAIN menu.21
    The lamp is approaching the end of its product lifetime.
    Replace the lamp.35, 36
    Pictures appear 
    blurry.Either the focus and/or horizontal phase settings are not 
    properly.
    Adjust the focus using the focus buttons, and/or H PHASE using 
    the menu function.
    14
    The lens is dirty or misty.
    Clean the lens by referring to the section “Caring For The Lens”.38
    Input signal 
    changes with no 
    operation.The INPUT dial is set between the click points.
    Turn the INPUT dial and set it at a click point.
    14 
    						
    							ViewSonic  PJ1172 44
    Specifications
    NOTE
    • This specifications are subject to change without notice.
    Item Specification
    Product name
    Liquid crystal projector
    Liquid crys-
    tal panelPanel size
    2.5 cm (0.99 type)
    Drive system
    TFT active matrix
    Pixels
    786,432 pixels (1024 horizontal x 768 vertical)
    Lens Zoom lens F=1.7~2.4 f=30.5~45.8 mm
    Lamp 310 W UHB
    Speaker 1.0W + 1.0W (Stereo)
    Power supply AC100 ~ 120V, 5.2A / AC220 ~ 240V, 2.2A
    Power consumption 470 W
    Temperature range 0°C ~ 35°C (Operating)
    Size 420(W) x 160(H) x 320(D) mm (not including protruding parts)
    • Please refer to the figure of the section “TECHNICAL” of the end of 
    this manual.
    Weight (mass) 7.7kg
    PortsRGB Input Ports
    RGB
    M1-D
    BNC (R,G,B,H,V)
    VIDEO Input Ports
    VIDEO IN
    S-VIDEO
    COMPONENT
    (CR/PR, CB/PB, Y)
    AUDIO Input Ports
    AUDIO IN 1
    AUDIO IN 2
    AUDIO IN R/LRGB output port
    RGB OUT
    Audio output port
    AUDIO OUT
    Control port
    CONTROL
    Other ports
    NETWORK
    REMOTE CONTROL
    DC OUT
    Optional
    Parts
    LampRLC-006
    Air filter• Please call ViewSonic for the part number.
    Others• Please consult your dealer. 
    						
    							ViewSonic  PJ1172 45
    Customer Support
    For technical support or product service, see the table below or contact your reseller.
    NOTE: You will need the product serial number.
    Country/Region Web site T = Telephone
    F = FAXEmail
    United States www.viewsonic.com/supportT: (800) 688-6688
    F: (909) [email protected]
    Canada www.viewsonic.com/supportT: (800) 688-6688
    F: (909) [email protected]
    United Kingdom www.viewsoniceurope.comT:  0800 833 648
    F: (01293) [email protected]
    Europe, Middle East, 
    Baltic countries, and 
    North Africawww.viewsoniceurope.com Contact your reseller [email protected]
    Australia and New 
    Zealandwww.viewsonic.com.auT: +61 2 9906 6277
    F: +61 2 9906 [email protected]
    Singapore/India and 
    Southeast Asiawww.viewsonic.com.sgT: 65 6273 4018
    F: 65 6273 [email protected]
    South Africa www.viewsonic.com/asiaT: 886 2 2246 3456
    F: 886 2 8242 [email protected]
    Other Asia/ Pacific 
    countrieswww.viewsonic.com.twT: 886 2 2246 3456
    F: 886 2 8242 [email protected]
    Taiwan www.viewsonic.com.twT: (0800) 061 198
    F: +886(2) [email protected]
    China www.viewsonic.com.cnT: (800) 820-3870
    F: (021) 623 [email protected] 
    						
    All ViewSonic manuals Comments (0)

    Related Manuals for ViewSonic Projector Pj1172 User Manual