ViewSonic CD4620 28 CONFIGURATION 1 AUTO SETUP * : INPUT RGB3,4 only y Press SET button to automatically adju st screen size, horizontal position, vertical position, clock, clock phase, white level and black level. y Press EXIT button to cancel execution AUTO SETUP and then will return to the previous menu. AUTO ADJUST * : INPUT RGB3,4 only y Selecting the auto adjust ON/OFF. y Selecting ON when changing the timing, the horizontal positi on, vertical position and clock-phase will adjust automatically. POWER SAVE y Selecting RGB ON, the monitor will go to power management mode when RGB1,2,3,4 sync is lost. y Selecting VIDEO ON, the monitor will go to power management mode after about 10 minutes delay from when DVD/HD and VIDEO input signal is lost. LANGUAGE y OSD control menus are available in eight languages. (E nglish, German, Spanish, French, Chinese and Russian) SCREEN SAVER *Select SCREEN SAVER functions to reduce the risk of the image persistence. y BRIGHTNESS: The brightness is decreased when selected ON. y MOTION: Image is slightly expanded and moves 4 directions (UP, DOWN, RIGHT, LEFT) periodically (Need setting the time for movement). y Movement area is approximately +/- 10mm from original position; y Please locate the important information such as text within 90% area of screen image. y See note (1) for this functions. y PIP and STILL will be disabled when MOTION is active. COLOR SYSTEM * : INPUT VIDEO, VIDEO only y Selecting the Color System depends on your input video format. y AUTO: NTSC, PAL, SECAM, PAL60 or 4.43 NTSC is automatically selected. y NTSC: Specific selection of NTSC. y PAL: Specific selection of PAL. y SECAM: Specific selection of SECAM. y PAL-60: Specific selection of PAL60. y 4.43NTSC: Specific selection of 4.43 NTSC. CONFIGURATION RESET y Selecting the CONFIGURATION RESET allows you to reset all configuration settings. y Select Yes and press SET button to restore the factory preset data. y Press EXIT button to cancel and return the previous menu. FACTORY RESET y Selecting YES allows you to reset PICTURE, SCR EEN, AUDIO, CONFIGURATION1,2 and ADVANCED OPTION will be back to factory settings (except LANGUAGE, DATE & TIME and SCHEDULE). y Select YES and press SET button to restore the factory pres et data. Press EXIT button to cancel and return the previous menu.
ViewSonic CD4620 29 CONFIGURATION 2 OSD TURN OFF y The OSD control menu will stay on as long as it is use. In the OSD Turn Off submenu, you can select how long the monitor waits after the last touch of a button to shut off the OSD control menu. y The preset choices are 5 -120 seconds. INFORMATION OSD y Selects the information OSD display or not. y The information OSD will display when input signal or source change or warning message like as no-signal or out-of range. y A time between 1 to 10 seconds is available. OFF TIMER y To select OFF TIMER mode ON/OFF. y In the OFF TIMER menu, you can preset the monitor to automatically power down. y A time between 1 to 24 hours is available. y When the OFF TIMER is set, the SCHEDULE settings will be disabled. OSD H POSITION y Adjusts the horizontal position of the OSD menu. OSD V POSITION y Adjusts the vertical position of the OSD menu. MONITOR INFORMATION y Indicates the model and serial number of your monitor.
ViewSonic CD4620 30 ADVANCED OPTION INPUT RESOLUTION * : INPUT RGB3,4 only y Selects to decision of input signal about below timings, 1024x768, 1280x768 and 1360x768. y AUTO: Determines the resolution automatically. y 1024x768: Determines the resolution as 1024x768 y 1280x768: Determines the resolution as 1280x768 y 1360x768: Determines the resolution as 1360x768 y The setting you select becomes effectiv e when POWER is turned OFF and ON again. BLACK LEVEL EXPANSION * : INPUT RGB1,2(HDMI INPUT MODE-HD), VIDEO, VIDEO only y Selects a level of black expansion from “OFF”, “MIDDLE” and “HIGH.” y In case of go under the black cut-off level, pleas e adjust the “Black level” in moderation on OSD menu. GAMMA SELECTION y Selects a display gamma. y 2.2 y 2.4 y S gamma y Native y NOTE: sRGB picture mode is standard and cannot be changed. SCAN MODE * : INPUT DVD/HD, VIDEO, VIDEO only y Changes the display area of the image. y OVERSCAN: Set to display area about 95% y UNDERSCAN: Set to display area about 100% SCAN CONVERSION * : INPUT DVD/HD, VIDEO, VIDEO only y Selects IP (Interlace to Progressive) converter function. y PROGRESSIVE: Enable the IP function, to convert interl ace signal to progressive. Normally use this setting. y INTERLACE*: Disable the IP function. y *NOTE: This mode is better suited for motion pict ures, but it increases chance of image retention. FILM MODE * : INPUT DVD/HD, VIDEO, VIDEO only y Selects Film mode function. y AUTO: Enable the Film mode function. This mode is better suit ed for movies, which is converted 24 Frames/sec source to DVD Video. We recommend to select “PROGRESSIVE” in “SCAN CONVERSION”. y OFF: Disable the Film mode function. This m ode is better suited for Broadcasting or VCR source. IR CONTROL y Selects the operation mode of the wireless remote controller when multiple CD4620 monitors are connected via RS-232C. y The item in this menu will become effective by pressing “SET” button on the selected item. y NORMAL: The monitor will be controlled normally by wireless remote controller. y PRIMARY: The first CD4620 monitor of those mult i-connected via RS-232C is designated as PRIMARY. y SECONDARY: CD4620 monitors other than the first one mult i-connected via RS-232C are designated as SECONDARY. y LOCK: Disable the monitor control by infrared wireless remote controller. y Keep pressing “DISPLAY” button during 5 sec or more, this setting will return to “NORMAL”.
ViewSonic CD4620 31 TILING y TILING demonstrates multiple screens. This feature provides a single large screen using up to 25 monitors. y It will be able to divide up to 5 each H and V. y This requires you to feed the PC output in to each of the monitors through a distributor. y H MONITORS: Select number of horizontal divide. y V MONITORS: Select number of vertical divide. y POSITION: Select a position to expand the screen. y FRAME COMP: Works in tandem with TILING to compensate for the width of the tile bezels in order to accurately display the image. y ENABLE: Select “YES”, the monitor will expand the selected position. y PIP and STILL will be disabled when “TILING” is activated. POWER ON DELAY y Adjusts the delay time from “standby” to “power on” mode. y “POWER ON DELAY” time is selectable from OFF, 2s ec, 4sec, 6sec, 8sec, 10sec, 20sec, 30s ec, 40sec and 50sec. DATE AND TIME y Adjusts the current date and time for internal clock. y You should set this functi on when you use “SCHEDULE”. SCHEDULE y Programs the monitors working schedule. y Schedule the power on and power off with hour and a day of the week. Also sets the input port. y This OSD cant remove except EXIT. (see “NOTE 2” on page 30 for further information) MONITOR ID y ID numbers for remote control are assigned to CD4620 monitors that are multi-connected via RS-232C. y ID numbers 1 to 26 are selectable. DDC/CI y Use to turn ON or OFF the DDC/CI communi cation function. Select ON for normal use. SYNC TYPE y Select “0.3V” for 0.3 Composite Sync. y Select “TTL” for TTL Sync. ADVANCED OPTION RESET y Selecting ADVANCED OPTION reset allows you to reset a ll OSD settings from ADVANCED OPTION settings, except for DATE & TIME. y Select “YES” and press “SET” button to restore the factory preset data. y Press “EXIT” button to cancel and then return the previous menu. NOTE 1: IMAGE PERSISTENCE y Please be aware that LCD Technology may experience a phenomena known as Image Persistence. Image Persistence occurs when residual or “ghost” image of a previous im age remains visible on the screen. Unlike CRT monitors, LCD monitors’ image persistence is not permanent, but constant images being displayed for a long period of time should be avoided. y To alleviate image persistence, turn off the monitor for as long as the previous image was displayed. For example, if an image was on the monitor for one hour and a residual image re mains, the monitor should be turned off for one hour to erase the image. y As with all personal display devices, ViewSonic recommends displaying moving images and using a moving screen saver at regular intervals whenever the screen is id le or turning off the monitor when not in use. Please set “POWER SAVE”, “SCREEN SAVER”, “DATE &TIM E” and “SCHEDULE” functions to further reduce the risk of Image persistence.
ViewSonic CD4620 32 For long life use of Public Display < Image Sticking of LCD Panel > When LCD panel is operated continuously fo r long hours, a trace of electric charge remains near the electrode inside LCD, and residual or “ghost” image of previ ous image may be observed. (Image Persistence) Image Persistence is not permanent, but when fixed image is di splayed for long period, ionic impurities inside LCD are accumulated along the displayed image, and it is observed permanently. (Image Sticking) < Recommendations > For preventing the fast transition to Image Sticking, and for longer life usage of LCD, following are recommended. 1. Fixed image should not be displayed for long peri od, and changed to another images with short cycle. 2. When no use, please turn off the monitor by remote c ontrol, or use Power Management Function of monitor or use Schedule Function of monitor. 3. Reducing the environmental temperat ure is effective for long life use. 4. Please use Screen Saver Mode of monitor. NOTE 2: HOW TO SETUP SCHEDULE y Using the “SCHEDULE” function allows you to set up to seven different scheduled time intervals when the LCD Monitor will be activated. y You can select the time the monitor turns on and turns off, the day of week the monitor is activated, and which input source the monitor will use for each scheduled activation per iod. A check mark in the box next to the number of the schedule indicates that the selected schedule is in effect. y To select which schedule to set, use the up/down arro ws to move the number (1 to 7) of the schedule. y Use the (+) and (-) buttons to move the cursor horizontally within the particular schedule. Use the ( S) and ( T) buttons to increase time and select input port. The “SET” button is used to make a selection. y If you create a schedule but do not want to use a power on time, select “--” in the “ON” time slot. y If you do not want to use a power off time select “--” in the OFF time slot. y If there is no input selected (“--” showing in the input s pot) the input from the previous schedule will be used. y The selection of EVERY DAY within a schedule takes priority over other schedules that are set up to operate weekly. y When schedules are overlapping, scheduled Power ON time has priority over scheduled Power OFF time. y If there are two schedules programmed for the same time, then the highest numbered schedule has priority. When the “OFF TIMER” is set, the “SCHEDULE” function is disabled. NOTE 3: “PIP”, “POP” and “SIDE BY SIDE” The following table shows the combination of signal input s under which the “PIP” and “POP” modes function. These modes do not function however when the screen size is “CUSTOM” or “REAL”. SUB RGB1 RGB2 RGB3 RGB4DVD/HDVIDEOVIDEO RGB1 ± ± ± ± ± { { RGB2 ± ± ± ± ± { { {:Supported RGB3 ± ± ± ± ± { { ±: Not supported DVD/HD ± ± ± ± ± { { VIDEO { { { { { ± ± MAIN VIDEO { { { { { ± ± Press the “PIP ON/OFF” buttons on the remote control to change between “PIP”, “POP” and “SIDE BY SIDE” mode as shown in the diagram below. PIP POP SIDE BY SIDE ASPECT SIDE BY SIDE FULL OFF PIP”, “POP” mode resolution (Reference) PIP SIZE YSMALL Z : 450 dots X 338 dots YMIDDLE Z : 675 dots X 450 dots YLARGE Z : 900 dots X 675 dots POP SIZE : 450 dots X 338 dots
ViewSonic CD4620 33 < Remote control numbering function > By connecting multiple CD4620 monitors using RS-232C cables, you can control any one monitor or all the monitors by one remote controller. 1. Assign arbitrary ID number to each of mult i-connected CD4620 monitors using MONITOR ID. ID numbers 1 to 26 are selectable. It is recommended to assign sequential ID numbers from 1 and up. 2. The remote control mode of the first CD4620 monitor is se t to PRIMARY and those of the other monitors are set to SECONDARY. 3. When you direct the remote controller at the remote c ontrol signal sensor of the PRIMARY monitor and press the DISPLAY button on the remote controller, the ID se lection OSD appears at the upper left of the screen. ID number of the currently viewed monitor Select the ID number of the monitor you want to control using the +/- button on the remote controller. The ID of the monitor you want to control is displayed at the upper left of its screen. By selecting ALL, you can control all the multi-connected monitors. 4. Direct the remote controller at the remote c ontrol signal sensor of the PRIMARY monitor. OSD appears on the monitor having the ID number you selected. NOTE: When the ID selection OSD is being displayed on the PR IMARY monitor, press the DISPLAY button on the remote controller again to cancel the ID selection OSD and then control the monitor you selected. HINT: If you set the remote control mode wrongly and remote cont rol operation becomes unavailable, press any button on the control panel of the monitor to display the OSD screen and change the remote control mode using ADVANCED OPTION. By pressing and holding down the DISPLAY button on the remote control for 5 seconds or longer, the remote control mode is initialized to NORMAL.
ViewSonic CD4620 34 Controlling the LCD monitor via RS-232C Remote Control This LCD monitor can be controlled by connecting a personal computer with a RS-232C terminal. Functions that can be controlled by a personal computer are: Connection LCD Monitor + PC NOTE: We have two kinds of RS-232 protocol including serious connection and no serious connection that can use by user.
ViewSonic CD4620 35 Appendix: Installing and removing stands How to install stands 1. Please turn monitor off. 2. After inserting stand in guide block, fast en Thumbscrews on both sides of the monitor. NOTE: Install the stands so that their longer portions come to the front. How to remove the stands 1. Spread the protective sheet on t he fl at surface, such as a desk. 2. Place monitor on the protective sheet. 3. Remove screws with a screwdriver and place them in a safe place for reuse. * Stand is not supply. (Stand sold as an option accessory) Screws Longer portion comes to the front. Stands
ViewSonic CD4620 36 Features Reduced Footprint: Provides the ideal solution for envir onments requiring superior image quality but with size and weight limitations. The monitor’s small footprint and low weight allow it to be moved or transported easily from one location to another. Color Control Systems: Allows you to adjust the colors on your screen and customize the color accuracy of your monitor to a variety of standards. sRGB Color Control: A new optimized color management standard which allows for colo r matching on computer displays and other peripherals. The sRGB standard, which is based on a calibrated color space, allo ws for optimal color representation and backward compatibility with other common color standards. OSD (On-Screen-Display) Controls: Allow you to quickly and easily adjust all elements of your screen image via simple to use on-screen menus. Plug and Play: The Microsoft® solution with the Windows® 95/98/Me/2000/XP operat ing system facilitates setup and installation by allowing the monitor to send its capabilities (such as screen size and resolu tions supported) directly to your computer, automatically optimizing display performance. Intelligent Power Manager System: Provides innovative power-s aving methods that allow the monitor to shift to a lower power consumption level when on but not in use, saving two-thirds of your monitor energy costs, reduci ng emissions and lowering the air conditioning costs of the workplace. Multiple Frequency Technology: Automatically adjusts monitor to the display card’s sc anning frequency, thus displaying the resolution required. FullScan Capability: Allows you to use the entire screen area in most resolutions, significantly expanding image size. Wall Mounting Interface: Allows for the monitor to be mounted on a wall or an arm using any third party compliant device. VIEWSONIC recommends using mounting interface that comply with TÜV-GS and/or UL1678 standard in North America. TILING, Frame compensation: Demonstrates multiple screens with an accurate image and compensates for the bezel width. ZOOM: Expands the image individually for horizontal and vertical direction. Self-diagnosis: When an internal error should occur, a failure state will be indicated.
ViewSonic CD4620 37 Troubleshooting No picture • The signal cable should be completely connected to the display card/computer. • The display card should be completely seated in its slot. • Front Power Switch and computer power switch should be in the ON position. • Check to make sure that a supported mode has been se lected on the display card or system being used. (Please consult display card or sy stem manual to change graphics mode.) • Check the monitor and your display card with respect to compatibility and recommended settings. • Check the signal cable connector for bent or pushed-in pins. • If nothing is displayed on the screen when HDCP device is connected, reset the power of the device. Power Button does not respond • Unplug the power cord of the monitor from the AC outlet to turn off and reset the monitor. Image persistence • Please be aware that LCD Technology may experience a phenomenon known as Image Persistence. Image Persistence occurs when a residual or “ghost” image of a previous image remains visible on the screen. Unlike CRT monitors, LCD monitors’ image persistence is not permanent, but constant images being displayed for a long period of time should be avoided. To alleviate im age persistence, turn off the monitor for as long as the previous image was displayed. For example, if an image was on the monitor fo r one hour and a residual image remains, the monitor should be turned off for one hour to erase the image. NOTE: As with all personal display devices, VIEWSONIC recommends displaying moving images and using a moving screen saver at regular intervals whenever the screen is id le or turning off the monitor when not in use. Image is unstable, unfocused or swimming is apparent • Signal cable should be completely attached to the computer. • Use the OSD Image Adjust controls to focus and adjust display by increasing or decreasing the fine adjustment. When the display mode is changed, the OSD Image Adjust settings may need to be re-adjusted. • Check the monitor and your display card with res pect to compatibility and recommended signal timings. • If your text is garbled, change the video mode to non-interlace and use 60 Hz refresh rate. Image of component signal is greenish • Check to see if the DVD/HD input connector is selected. LED on monitor is not lit (no green or red color can be seen) • Power Switch should be in the ON position and power cord should be connected. • Make certain the computer is not in a pow er-saving mode (touch the keyboard or mouse). RED LED on monitor is blinking • A certain failure might have occurred, please contac t your nearest authorized VIEWSONIC service facility. Display image is not sized properly • Use the OSD Image Adjust controls to increase or decrease the coarse adjustment. • Check to make sure that a supported mode has been se lected on the display card or system being used. (Please consult display card or sy stem manual to change graphics mode.) Selected resolution is not displayed properly • Use OSD Display Mode to enter Information menu and conf irm that the appropriate resolution has been selected. If not, select corresponding option. No Sound • Check to see if speaker cable is properly connected. • Check to see if mute is activated. • Check to see if volume is set at minimum. Remote Control is not available • Check the Remote Control’s batteries status. • Check if batteries are inserted correctly. • Check if the Remote Control is pointing at the monitor’s remote sensor. “SCHEDULE”/“OFF TIMER” function is not working properly • The “SCHEDULE” function will be disabled when the “OFF TIMER” is set. • If the “OFF TIMER” function is enable and the power to the LCD monitor is turned off if the power supply is interrupted unexpectedly, then the “OFF TIMER” will be reset. Stripe Noise Either light vertical or horizontal stripes may appear, depending on the specific display pattern. This is no product fault or degradation. “NO SIGNAL” is displayed on the screen Image may not be displayed right after HDCP device is connected.