Vision 90t/100t Color Gamut Adjustment Vidikron Vision Model 90t and Model 100t Owner’s Operating Manual A-3 Figure A-3. Vision 90t/100t Secondary RS-232 Port 4. Connect the color sensor to any available COM or USB port. 5. Launch HyperTerminal. Open a connection using these parameters: 19200 baud, 8 data bits, no parity,1 stop bit and no flow control. 6. Press . The Vision 90t/100t responds with “+>” to indicate that it is ready to accept commands. 7. Start your color analyzer. Position the sensor approximately 6 to 12 inches from the screen, facing it at a slight angle (upward or to one side) so that the color of the screen is included in the calibration. A.3 Serial Command Syntax Table A-1 lists the serial command set for color gamut adjustments. The “Parameter (min/max)” column shows the valid parameter ranges, or “NA” for commands that take no parameters. When you enter a valid command, the Vision 90t/100t executes it and acknowledges it with a plus sign on the command line (+ >). When you enter an invalid command – one that is misspelled or followed by values outside the valid range for that command – the Vision 90t/100t ignores it and returns a minus sign (- >). Table A-1. Serial Commands for Gamut Adjustment CommandParameter (min/max)Value Stored?Description GAMUT WHITENANADisplays white field on screen for measuring x and y coordinates; shows current x and y coordinates for white on the command line. GAMUT REDNANADisplays red field on screen for measuring x and y coordinates; shows current x and y coordinates for red on the command line.
Vision 90t/100t Color Gamut Adjustment A-4 Vidikron Vision Model 90t and Model 100t Owner’s Operating Manual A.4 Adjusting the Gamut 1. In HyperTerminal, type gamut white and press . The Vision 90t/100t displays a white field on the screen and the current x and y coordinates for white on the command line. 2. Using the color analyzer, measure the x and y coordinates for about 15 seconds. Make a note of the results. 3. In HyperTerminal, use the gamut set white command to change the x and y coordinates to the values you obtained in Step 2. For example, if the readings were x=0.284 and y=0.294, type gamut set white 0.284 0.294 and press . 4. To confirm the change, repeat Step 1. The displayed x and y values should match what you just entered. 5. Type gamut red and press . The Vision 90t/100t displays a red field on the screen and the current x and y coordinates for red on the command line. 6. Repeat Step 2. 7. In HyperTerminal, use the gamut set red command to change the x and y coordinates to the values you obtained in Step 6. 8. To confirm the change, repeat Step 5. The displayed x and y values should match what you just entered. 9. Type gamut green and press . The Vision 90t/100t displays a green field on the screen and the current x and y coordinates for green on the command line. 10. Repeat Step 2. GAMUT GREENNANADisplays green field on screen for measuring x and y coordinates; shows current x and y coordinates for green on the command line. GAMUT BLUENANADisplays blue field on screen for measuring x and y coordinates; shows current x and y coordinates for blue on the command line. GAMUT SET WHITE [x] [y]x = 0.0 / 0.8 y = 0.0 / 0.9 YESSets x and y coordinates for white. GAMUT SET RED [x] [y]x = 0.0 / 0.8 y = 0.0 / 0.9 YESSets x and y coordinates for red. GAMUT SET GREEN [x] [y]x = 0.0 / 0.8 y = 0.0 / 0.9 YESSets x and y coordinates for green. GAMUT SET BLUE [x] [y]x = 0.0 / 0.8 y = 0.0 / 0.9 YESSets x and y coordinates for blue. GAMUT OFFNANAApplies new gamut setting (if changed) and goes back to normal picture. Table A-1. Serial Commands for Gamut Adjustment (continued) CommandParameter (min/max)Value Stored?Description
Vision 90t/100t Color Gamut Adjustment Vidikron Vision Model 90t and Model 100t Owner’s Operating Manual A-5 11. In HyperTerminal, use the gamut set green command to change the x and y coordinates to the values you obtained in Step 10. 12. To confirm the change, repeat Step 9. The displayed x and y values should match what you just entered. 13. Type gamut blue and press . The Vision 90t/100t displays a blue field on the screen and the current x and y coordinates for blue on the command line. 14. Repeat Step 2. 15. In HyperTerminal, use the gamut set blue command to change the x and y coordinates to the values you obtained in Step 14. 16. To confirm the change, repeat Step 13. The displayed x and y values should match what you just entered. 17. Type gamut off and press . The Vision 90t/100t stores the new x and y coordinates and returns to normal operation. When you have completed the gamut adjustments, proceed with the Display Color adjustments described on page 38.
Vision 90t/100t Color Gamut Adjustment A-6 Vidikron Vision Model 90t and Model 100t Owner’s Operating Manual Notes: